Physical working principles of medical radar Ø Aardal, Y Paichard, S Brovoll, T Berger, TS Lande, SE Hamran IEEE Transactions on Biomedical Engineering 60 (4), 1142-1149, 2012 | 100 | 2012 |
In-body to on-body ultrawideband propagation model derived from measurements in living animals PA Floor, R Chávez-Santiago, S Brovoll, Ø Aardal, J Bergsland, ... IEEE journal of biomedical and health informatics 19 (3), 938-948, 2015 | 85 | 2015 |
Time-lapse imaging of human heart motion with switched array UWB radar S Brovoll, T Berger, Y Paichard, Ø Aardal, TS Lande, SE Hamran IEEE Transactions on Biomedical Circuits and Systems 8 (5), 704-715, 2014 | 57 | 2014 |
Experimental ultra wideband path loss models for implant communications C Garcia-Pardo, A Fornes-Leal, N Cardona, R Chávez-Santiago, ... 2016 IEEE 27th Annual International Symposium on Personal, Indoor, and …, 2016 | 45 | 2016 |
Chest movement estimation from radar modulation caused by heartbeats Ø Aardal, SE Hamran, T Berger, Y Paichard, TS Lande 2011 IEEE Biomedical Circuits and Systems Conference (BioCAS), 452-455, 2011 | 25 | 2011 |
Radar cross section of the human heartbeat and respiration in the 500MHz to 3GHz band Ø Aardal, SE Hamran, T Berger, J Hammerstad, TS Lande 2011 IEEE Radio and Wireless Symposium, 422-425, 2011 | 24 | 2011 |
Detecting changes in the human heartbeat with on-body radar Ø Aardal, S Brovoll, Y Paichard, T Berger, TS Lande, SE Hamran 2013 IEEE Radar Conference (RadarCon13), 1-6, 2013 | 23 | 2013 |
Medical radar literature overview Ø Aardal, J Hammerstad | 18 | 2010 |
Time-lapse imaging of human heartbeats using UWB radar S Brovoll, T Berger, Y Paichard, Ø Aardal, TS Lande, SE Hamran 2013 IEEE Biomedical Circuits and Systems Conference (BioCAS), 142-145, 2013 | 17 | 2013 |
Optimal frequency range for medical radar measurements of human heartbeats using body-contact radar S Brovoll, Ø Aardal, Y Paichard, T Berger, TS Lande, SE Hamran 2013 35th Annual International Conference of the IEEE Engineering in …, 2013 | 15 | 2013 |
Experimental investigation into radar‐based central blood pressure estimation LE Solberg, Ø Aardal, T Berger, I Balasingham, E Fosse, SE Hamran IET Radar, Sonar & Navigation 9 (2), 145-153, 2015 | 14 | 2015 |
Radar cross section of the human heartbeat and respiration Ø Aardal, SE Hamran, T Berger, J Hammerstad, TS Lande 2010 Biomedical Circuits and Systems Conference (BioCAS), 53-57, 2010 | 8 | 2010 |
Modeling FMCW radar for subsurface analysis S Eide, T Casademont, ØL Aardal, SE Hamran IEEE Journal of Selected Topics in Applied Earth Observations and Remote …, 2022 | 5 | 2022 |
Radar monitoring of heartbeats and respiration Ø Aardal | 5 | 2013 |
Close range ultra wideband microwave imaging in a non-homogeneous background T Berger, SE Hamran, Y Paichard, Ø Aardal Proc. IASTED Int. Conf. Signal and Image Processing, 188-194, 2011 | 5 | 2011 |
Phase distortions in radar respiration monitoring Ø Aardal, S Brovoll, T Berger, I Balasingham, SE Hamran 2017 First IEEE MTT-S International Microwave Bio Conference (IMBIOC), 1-4, 2017 | 3 | 2017 |
Radar sensitivity to human heartbeats and respiration Ø Aardal, S Brovoll, Y Paichard, T Berger, TS Lande, SE Hamran Radar Sensor Technology XIX; and Active and Passive Signatures VI 9461, 400-410, 2015 | 1 | 2015 |
Post processing of raw data recorded with an ECG-vest Ø Aardal | 1 | 2008 |
Distortion effects in a switch array UWB radar for time-lapse imaging of human heartbeats S Brovoll, T Berger, Ø Aardal, TS Lande, SE Hamran Radar Sensor Technology XVIII 9077, 531-540, 2014 | | 2014 |
Close range microwave imaging of human chest Y Paichard, T Berger, Ø Aardal, SE Hamran Proceedings of the 4th International Symposium on Applied Sciences in …, 2011 | | 2011 |