Scholar Results 1 - 10 of about 35 citing Rohrschneider: Scanning laser fundus perimetry before laser photocoagulation of well defined.... (0.13 sec) 

Fundus autofluorescence and fundus perimetry in the junctional zone of geographic atrophy …

- iovs.org
S Schmitz-Valckenberg, S Bultmann, J … - Investigative ophthalmology & visual science, 2004 - ARVO
RESULTS. Thirty-nine eyes of 39 patients with GA were included. Group 2 had a
higher percentage of all test points outside the GA area, with decreased retinal
sensitivity (44.9% ± 28.7%) compared with group 1 (20.7% ± 12.7%; P = ...
Cited by 53 - Related articles - BL Direct - All 4 versions

Microperimetry—comparison between the micro perimeter 1 and scanning laser …


K Rohrschneider, C Springer, S Bültmann, HE … - American journal of ophthalmology, 2005 - Elsevier
There was good concordance of results, with 75% (51 of 68 eyes) showing an equal
defect. Whereas the MP1 showed larger defects (depth and size) in 23.5% (16/68)
of eyes studied than the SLO, the defects appeared larger with the SLO in 1 ...
Cited by 53 - Related articles - All 3 versions

Fixation pattern and macular sensitivity in eyes with subfoveal choroidal …


E Midena, PP Radin, E Pilotto, A Ghirlando, … - Seminars in Ophthalmology, 2004 - informahealthcare.com
Methods. 118 eyes of 98 consecutive patients with subfoveal CNV secondary to AMD
were evaluated. Best corrected visual acuity (ETDRS charts), fundus photography,
and fluorescein angiography were performed. Microperimetry (fundus-related ...
Cited by 52 - Related articles - All 5 versions

Autologous translocation of the choroid and retinal pigment epithelium in age-related …


AM Joussen, FMA Heussen, S Joeres, H Llacer … - American journal of ophthalmology, 2006 - Elsevier
Preoperative distant visual acuity ranged from 20/800 to 20/40. Reading vision
ranged from 1.4 logarithm of reading acuity determination (logRAD) to 0.5 logRAD
(0.04 to 0.32 Snellen equivalent). Revision surgery was required in 22 eyes ...
Cited by 45 - Related articles - Library Search - All 3 versions

Effects of verteporfin therapy on central visual field function


UM Schmidt-Erfurth, H Elsner, N Terai, A … - Ophthalmology, 2004 - Elsevier
The trial was performed as a single-center, double-masked study. Patients were
examined before therapy and continuously in 3-month intervals during 2 years of
follow-up. A scanning laser ophthalmoscope (SLO) was used to perform ...
Cited by 45 - Related articles - All 14 versions

Patient selection for macular translocation surgery using the scanning laser …


GY Fujii, E de Juan, J Sunness, MS Humayun, … - Ophthalmology, 2002 - Elsevier
To evaluate the use of the scanning laser ophthalmoscope (SLO) as a predictor
for potential visual improvement in eyes with subfoveal choroidal
neovascularization (CNV) secondary to age-related macular degeneration ...
Cited by 43 - Related articles - All 10 versions

Scanning laser ophthalmoscope fundus perimetry before and after laser photocoagulation for …


K Rohrschneider, S Bültmann, R Glück, FE … - American journal of ophthalmology, 2000 - Elsevier
METHODS: Thirty eyes of 30 patients with clinically significant macular edema as
a result of diabetic retinopathy were prospectively examined before and at least
3 months after focal laser treatment with automatic fundus threshold ...
Cited by 37 - Related articles - BL Direct - All 14 versions

Diabetic macular edema: correlation between microperimetry and optical coherence …

- iovs.org
S Vujosevic, E Midena, E Pilotto, PP Radin, L … - Investigative ophthalmology & visual science, 2006 - ARVO
RESULTS. The 61 included eyes were graded, by two retinal specialists, for
diabetic macular edema as follows: 16 were graded as no macular edema (NE), 30
as non–clinically significant macular edema (NCSME), and 15 as clinically ...
Cited by 36 - Related articles - BL Direct - All 3 versions

Fundus Perimetry with the Micro Perimeter 1 in Normal Individuals Comparison with …


C Springer, S Bültmann, HE Völcker, K … - Ophthalmology, 2005 - Elsevier
Differential light threshold values obtained with the MP1 and their difference
to differential light threshold values with the Octopus. Differential light
sensitivity was compared for 21 matching points in a rectangular test grid ...
Cited by 35 - Related articles - All 16 versions

Normal values for fundus perimetry with the scanning laser ophthalmoscope


K Rohrschneider, M Becker, N Schumacher, T … - American journal of ophthalmology, 1998 - Elsevier
Purpose: To evaluate the normal light sensitivity values for fundus perimetry
and their short time fluctuation (reliability) in normal volunteers of different
ages. After the development of full-threshold static fundus perimetry, age- ...
Cited by 33 - Related articles - BL Direct - All 6 versions