NT Choplin, DC Lundy - Ophthalmology, 2001 - Elsevier Consecutive subjects seen in a glaucoma clinic were imaged with the GDx. The masked printouts were
distributed to nine experienced users of the machine, who were asked to classify the scan from each
eye as normal, suspicious for ... Cited by 85 - Related articles - BL Direct - All 10 versions
- ►iovs.org DF Garway-Heath, MJ Greaney, J Caprioli - Investigative ophthalmology & visual …, 2002 - ARVO METHODS. Retardation measurements (for the 780-nm wavelength), given as RNFL thickness by the
scanning laser polarimeter, were obtained at the macula and PP retina in 45 eyes of 45 normal
subjects and 53 eyes of 53 patients ... Cited by 52 - Related articles - BL Direct - All 6 versions
AL Jones, NJL Sheen, RV North, JE Morgan - British Journal of …, 2001 - bjo.bmj.com RESULTS For the 1.74 mm circular scan, the mean coefficient of variation (COV) for the global RNFL
thickness measurement was 5% (SD 3%). This increased to 8% (3%) for quadrant measurements and to 9%
(3%) with further subdivision into ... Cited by 53 - Related articles - BL Direct - All 7 versions
NT Choplin, Q Zhou, RW Knighton - Ophthalmology, 2003 - Elsevier Scanning laser polarimetry estimates retinal nerve fiber layer (RNFL) thickness through measurement
of retardation of a polarized laser light passing through the naturally birefringent RNFL and
cornea. The commercial instrument, ... Cited by 51 - Related articles - All 12 versions
DS Greenfield - Current opinion in ophthalmology, 2002 - journals.lww.com There is mounting evidence that retinal nerve fiber layer (RNFL) loss precedes detectable visual
field loss in early glaucomatous optic neuropathy. However, examination and photography of the RNFL
is a difficult technique in many ... Cited by 46 - Related articles - BL Direct - All 3 versions
RN Weinreb, C Bowd, LM Zangwill - Journal of Glaucoma, 2002 - journals.lww.com Robert N. Weinreb, MD, Christopher Bowd, PhD, and Linda M. Zangwill, PhD ... Hamilton Glaucoma
Center and Diagnostic Imaging Laboratory, University of California, San Diego, California ...
Purpose: To determine if scanning ... Cited by 37 - Related articles - BL Direct - All 2 versions
- ►psu.edu [PDF] KA Vermeer, FM Vos, HG Lemij, AM Vossepoel - Computers in Biology and …, 2004 - Elsevier Retinal blood vessels are important structures in ophthalmological images. Many detection methods
are available, but the results are not always satisfactory. In this paper, we present a novel model
based method for blood vessel ... Cited by 33 - Related articles - All 11 versions
- ►eur.nl [PDF] TP Colen, HG Lemij - Journal of Glaucoma, 2003 - journals.lww.com Cited Here...: Two experienced observers judged 800 GDx scans on 400 randomly presented printouts
from 200 glaucoma patients and 200 age-matched normal subjects. The diagnosis was based on the
symmetry analysis printout and was ... Cited by 23 - Related articles - BL Direct - All 9 versions
DM Stein, G Wollstein, JS Schuman - Ophthalmology clinics of …, 2004 - pubmedcentral.nih.gov The detection and monitoring of glaucoma are multifactorial processes traditionally involving
several diagnostic modalities, including intraocular pressure measurements, subjective evaluation of
the optic nerve head (ONH), and ... Cited by 20 - Related articles - BL Direct - All 3 versions
M Iester, P Tizte, A Mermoud - Journal of Cataract & Refractive Surgery, 2002 - Elsevier Eleven normal volunteers were enrolled in the study. The optic disc of each eye was analyzed by the
GDx® Nerve Fiber Analyzer (Laser Diagnostic Technologies, Inc.), version 1.0.14. Using the standard
circle that appears as a 10-pixel ... Cited by 19 - Related articles - All 10 versions