Scholar Results 1 - 10 of about 23 citing Hayashi: Anterior capsule contraction and intraocular lens decentration and tilt after hydrogel.... (0.09 sec) 

Comparison of the stability of 1-piece and 3-piece acrylic intraocular lenses in the lens …


K Hayashi, H Hayashi - Journal of Cataract & Refractive Surgery, 2005 - Elsevier
The mean degrees of decentration and tilt in the 1-piece IOL group were similar
to those in the 3-piece IOL group throughout the follow-up. The ACD did not
change after surgery in the 1-piece group but showed significant shallowing ...
Cited by 31 - Related articles - All 9 versions

Relationship between posterior capsule opacification and intraocular lens biocompatibility


S Saika - Progress in retinal and eye research, 2004 - Elsevier
The type of healing process that occurs in response to cataract surgery and
intraocular lens (IOL) implantation is dependent on a complex set of variables.
Their interactions determine whether or not optical clarity is restored as ...
Cited by 31 - Related articles - All 5 versions

A prospective, randomised comparison of single and three piece acrylic foldable intraocular …

- nih.gov - Free from Publisher
R Nejima, K Miyata, M Honbou, T Tokunaga, T … - British Journal of Ophthalmology, 2004 - bjo.bmj.com
Methods: 20 patients underwent bilateral cataract surgery with a single piece
SA30AL IOL in one eye and a three piece MA30BA IOL in the other eye. The eyes
were randomly assigned to either a single or three piece lens. The amount ...
Cited by 24 - Related articles - BL Direct - All 8 versions

Elapsed time for capsular apposition to intraocular lens after cataract surgery


H Hayashi, K Hayashi, F Nakao, F Hayashi - Ophthalmology, 2002 - Elsevier
To examine when the anterior and posterior lens capsule completely become
apposed to optics of silicone and acrylic intraocular lenses (IOLs) implanted
after cataract surgery and to determine whether the different IOL materials ...
Cited by 24 - Related articles - All 9 versions

High-order aberrations with Hydroview H60M and AcrySof MA30BA intraocular lenses …


F Taketani, T Matsuura, E Yukawa, Y Hara - Journal of Cataract & Refractive Surgery, 2004 - Elsevier
Method: Twenty-four eyes of 14 patients with a Hydroview IOL and 25 eyes of 20
patients with an AcrySof IOL who had uneventful phacoemulsification and a best
corrected visual acuity better than 20/16 from 6 to 12 months after surgery ...
Cited by 22 - Related articles - All 8 versions

Intraocular lens factors that may affect anterior capsule contraction


K Hayashi, H Hayashi - Ophthalmology, 2005 - Elsevier
Three hundred thirty-one patients scheduled for bilateral cataract surgery were
studied to compare the degree of anterior capsule contraction in fellow eyes
that received different IOLs with regard to the following factors: (1) ...
Cited by 22 - Related articles - All 12 versions

Posterior capsule opacification after implantation of a hydrogel intraocular lens

- nih.gov - Free from Publisher
K Hayashi, H Hayashi - British Journal of Ophthalmology, 2004 - bjo.bmj.com
Results: The mean PCO value in the hydrogel group increased significantly
(p<0.0001), while that in the acrylic group did not show significant change. The
PCO value in the hydrogel group was significantly greater than that in the ...
Cited by 18 - Related articles - BL Direct - All 8 versions

Histology of anterior capsule opacification with a polyHEMA/HOHEXMA hydrophilic hydrogel …


S Saika, T Miyamoto, Y Ohnishi - Journal of Cataract & Refractive Surgery, 2003 - Elsevier
To evaluate the biocompatibility of various materials including a
poly(2-hydroxyethyl methacrylate [HEMA])/(6-hydroxyhexyl methacrylate [HOHEXMA])
hydrophilic hydrogel intraocular lens (IOL) (Hydroview®, Bausch & Lomb).
Cited by 14 - Related articles - All 9 versions

Prospective intrapatient comparison of 6.0-millimeter optic single-piece and 3-piece …


R Nejima, T Miyai, Y Kataoka, K Miyata, M … - Ophthalmology, 2006 - Elsevier
Copyright © 2006 American Academy of Ophthalmology Published by Elsevier Inc.
... To compare postoperative performance and stability of 6.0-mm optic single-
and 3-piece acrylic foldable intraocular lenses (IOLs).
Cited by 13 - Related articles - All 3 versions

Analysis of crystalline lens position


CY Hu, JH Jian, YP Cheng, HK Hsu - Journal of Cataract & Refractive Surgery, 2006 - Elsevier
A Scheimpflug anterior segment analyzer (EAS-1000, Nidek) was prospectively
applied to measure the cycloplegic crystalline lens position in subjects who had
not had previous ocular surgeries or who had been diagnosed previously with ...
Cited by 11 - Related articles - All 5 versions