Scholar Results 1 - 10 of about 38 citing Miglior: Intraobserver and interobserver reproducibility in the evaluation of ultrasonic.... (0.08 sec) 

Comparison of three methods of measuring corneal thickness and anterior …


W Buehl, D Stojanac, S Sacu, W Drexler, O Findl - American journal of …, 2006 - Elsevier
The upper (lower) limits of agreement for CCT measurements were 7.9 (−22.2) μm between AC-Master
and Pentacam, 17.6 (−32.5) μm between AC-Master and Orbscan, and 25.2 (−25.9) μm between
Pentacam and Orbscan. Correlation ...
Cited by 92 - Related articles - All 16 versions

Central corneal thickness measurement with the Pentacam Scheimpflug system, …

- oculus.de [PDF] 
Y Barkana, Y Gerber, U Elbaz, S Schwartz, G Ken- … - Journal of Cataract & …, 2005 - Elsevier
Repeatability was determined from 10 successive measurements in each of 4 healthy patients.
Reproducibility for the Pentacam Scheimpflug system was determined from measurements by 2 operators
in each of 24 patients; in these 24 ...
Cited by 85 - Related articles - All 34 versions

Repeatability and reproducibility of central corneal thickness measurement with …

- ophthonix.eu [PDF] 
B Lackner, G Schmidinger, S Pieh, MA … - Optometry & Vision …, 2005 - journals.lww.com
Results. The mean CCT values as determined with the different modalities (± standard deviation)
were: 542 ± 29 μm, 576 ± 37 μm, 530 ± 34 μm, and 552 ± 32 μm for rotating Scheimpflug
imaging, for uncorrected and for ...
Cited by 85 - Related articles - BL Direct - All 20 versions

Comparison of central corneal thickness measurements by rotating Scheimpflug …


S Amano, N Honda, Y Amano, S Yamagami, T Miyai, T … - Ophthalmology, 2006 - Elsevier
Corneal thickness measurements were compared among the 3 methods in 54 eyes of 54 subjects. Two sets
of measurements were repeated by a single examiner for each pachymetry in another 10 eyes of 5
subjects, and the intraexaminer ...
Cited by 44 - Related articles - All 3 versions

The effect of corneal thickness on intraocular pressure measurement in patients …


AC Browning, A Bhan, AP Rotchford, S Shah, HS … - British Journal of …, 2004 - bjo.bmj.com
Results: Mean IOP measurements in all three patient groups were significantly higher when measured
by OBF pneumotonometer. Linear regression analysis showed that patients with FED had a significant
increase in IOP with increasing CCT ...
Cited by 25 - Related articles - BL Direct - All 10 versions

Comparison of corneal thickness after the instillation of topical anesthetics: …

- duanessolution.com
SM Nam, HK Lee, EK Kim, KY Seo - Cornea, 2006 - journals.lww.com
Skip Navigation Links Home > January 2006 - Volume 25 - Issue 1 > Comparison of Corneal Thickness
After the Instillation of To... ... From the Department of Ophthalmology, Yonsei Institute of
Vision Research, Yonsei University ...
Cited by 23 - Related articles - BL Direct - All 6 versions

Central and peripheral pachymetry measurements according to age using the …


R Khoramnia, TM Rabsilber, GU Auffarth - Journal of Cataract & Refractive …, 2007 - Elsevier
Seventy-six healthy volunteers were enrolled in a clinical prospective study. Three consecutive
Pentacam measurements of 1 eye per subject were taken. Evaluated were the central corneal thickness
(CCT), corneal thickness at 4 ...
Cited by 23 - Related articles - All 11 versions

Orbscan global pachymetry: analysis of repeated measures


HB Fam, KL Lim, DANZ REINSTEIN - Optometry & Vision Science, 2005 - journals.lww.com
ABSTRACT: Purpose. The Orbscan II is a hybrid slit-scanning and Placido disc corneal topographer
capable mapping global pachymetry over a 10-mm corneal diameter. In this study, the repeatability of
the Orbscan global pachymetry was ...
Cited by 18 - Related articles - BL Direct - All 4 versions

Circadian variations in central corneal thickness and intraocular pressure in …

- nih.gov
P Fogagnolo, L Rossetti, F Mazzolani, N … - British Journal of …, 2006 - bjo.bmj.com
Methods: 30 patients with primary open angle glaucoma were hospitalised and underwent circadian
evaluations (at 8 pm, midnight, 4 am, 8 am, noon, and 4 pm) of supine and sitting IOP, respectively,
measured using a Perkins and a ...
Cited by 13 - Related articles - BL Direct - All 7 versions

Longitudinal changes in central corneal thickness and their relation to glaucoma …

- nih.gov
JS Weizer, SS Stinnett, LW Herndon - British Journal of Ophthalmology, 2006 - bjo.bmj.com
Methods: 39 patients (64 eyes) with open angle glaucoma, ocular hypertension, glaucoma suspect
status, or a normal eye examination were examined at two visits. CCT, age, race, sex, family history
of glaucoma, presence of diabetes ...
Cited by 12 - Related articles - BL Direct - All 7 versions