Web Images Videos Maps News Shopping Gmail more »
Sign in
Scholar Home  
  Advanced Scholar Search
Scholar Preferences
Scholar Results 1 - 10 of 10 citing Troost: Transpalpebral tonometry: reliability and comparison with Goldmann applanation tonometry.... (0.06 sec) 

Corneal structure and biomechanics: impact on the diagnosis and management of …

- duanesolution.com
KE Brown, NG Congdon - Current Opinion in Ophthalmology, 2006 - journals.lww.com
Purpose of review Highlights recent studies relating to the impact of corneal
structure and biomechanical properties on glaucoma evaluation and management.
Recent findings Central corneal thickness has been shown to play a role in ...
Cited by 13 - Related articles - BL Direct - All 3 versions

Are Disposable Prisms an Adequate Alternative to Standard Goldmann Tonometry Prisms …


AP Maino, LH Morgan, BL Hercules, AB Tullo - Ophthalmology, 2006 - Elsevier
Cited by 2 - Related articles - All 22 versions

Evaluation of the impedance tonometers TGDc-01 and iCare according to the international …


PC Ruokonen, T Schwenteck, J Draeger - Graefe's Archive for Clinical and Experimental …, 2007 - Springer
Abstract Background Two new tonometers have been introduced that are based on
the impedance principle. Both the TGDc-01 (transpalpebral measurement) and the
iCare (corneal mea- surement) do not require corneal anaesthesia. The ...
Cited by 2 - Related articles - BL Direct - All 3 versions

Rationale, Design, Methodology, and Baseline Data of a Population-Based Study in Rural …


YB Liang, DS Friedman, TY Wong, FH Wang, … - Ophthalmic Epidemiology, 2009 - informahealthcare.com
Purpose: To describe the rationale, design, methodology and baseline
characteristics of the Handan Eye Study (HES), a population-based study to
determine the prevalence and impact of visual impairment and major ocular ...
Cited by 1 - Related articles - All 6 versions

Effects of corneal thickness on intraocular pressure measured with three different …


H Murase, A Sawada, K Mochizuki, T … - Japanese Journal of Ophthalmology, 2009 - Springer
The Goldmann applanation tonometer (GAT) is consid- ered the gold standard
instrument for measuring intraocu- lar pressure (IOP). 1 Although Goldmann
tonometry is the most widely used method of measuring IOP, IOP measure- ...
Cited by 1 - Related articles - All 2 versions

OGS PRESIDENT'S MESSAGE


BV Bui, Z He, AJ Vingrys - revoptom.com
Much of this issue's content relates to tonometry and intraocular pressure
(IOP), a topic we once thought we understood. Yes, a test and its outcome we
long took for granted is now being questioned. Thinking about Goldmann ...
Related articles - Cached - All 3 versions

Central corneal thickness and Diaton transpalpebral tonometry


MI Toker, A Vural, H Erdogan, A Topalkara, MK … - Graefe's Archive for Clinical and Experimental …, 2008 - Springer
Abstract Background To examine the effects of central corneal thickness on the
measures obtained from transpalpebral tonometry (Diaton), and to identify
correlations between intraocular pressure (IOP) measurements with Diaton ...
Related articles - BL Direct - All 2 versions

Measurements of Intraocular Pressure by Goldmann Tonometry, Tonopen XL, and the …


G Shemesh, M Waisbourd, D Varssano, A … - Cornea, 2009 - journals.lww.com
Results: Forty-five eyes of 43 patients were enrolled in the study. The mean IOP
difference (6SD) was 20.42 6 5.83 mm Hg between GT and Tonopen and 3.20 6 7.55
mm Hg between GT and TGDc-01. The correlation coefficient was 0.84 between ...
Related articles - All 4 versions

[CITATION] Design of Automated Digital Eye Palpation Exam for Intraocular Pressure Measurement


AV Luce, ET Enikov, BJ Nelson

Goldmann-Applanationstonometrie und dynamische Konturtonometrie


EM Hoffmann, N Pfeiffer, L Barleon, FH Grus - Der Ophthalmologe, 2006 - Springer
Die intraokulare Druckmessung ist ein wichtiger Bestandteil der Glaukomdia-
gnostik und Verlaufskontrolle. Neben der als „Goldstandard“bezeichneten
Applana- tionstonometrie nach Goldmann (GAT) wurden in den letzten Jahren ...
Related articles - BL Direct


 


Go to Google Home - About Google - About Google Scholar

©2009 Google