W Chui, A Lam, D Chen, R Chiu - Ophthalmology, 2008 - Elsevier Intraocular pressure was determined in all subjects using the iCARE at both
central and temporal corneal regions. Corneal thickness at these 2 regions was
determined by ultrasonic pachymetry. Corneal hysteresis and corneal ... Cited by 12 - Related articles - All 2 versions
- ►uv.es [PDF] T Ferrer-Blasco, JM González-Méijome, R … - Journal of Cataract & Refractive Surgery, 2008 - Elsevier Several parameters changed significantly with age, particularly in patients in
their sixties and older. An increase in the blur component was mainly associated
with astigmatic progression and a trend toward against-the-rule orientation ... Cited by 9 - Related articles - All 16 versions
- ►duanesolution.com JM GONZÁLEZ-MÉIJOME, AON QueirOS, J … - Optometry & Vision Science, 2008 - journals.lww.com Results. Average intraoffice hour variability of IOP and corneal biomechanical
parameters were not statistically significant, showing a stable profile during
the hours of the day studied. An interesting finding was that although ... Cited by 3 - Related articles - BL Direct - All 4 versions
- ►duanesolution.com JMM Jorge, JM González-Méijome, A Queirós … - Journal of glaucoma, 2008 - journals.lww.com Skip Navigation Links Home > September 2008 - Volume 17 - Issue 6 > Correlations
Between Corneal Biomechanical Properties Measur... ... Disclosure: None of the
authors has a commercial or financial interest in the instruments or ... Cited by 2 - Related articles - All 6 versions
- ►duanesolution.com SP Mollan, JS Wolffsohn, M Nessim, M … - British Journal of Ophthalmology, 2008 - bjo.bmj.com Results: The difference in IOP values between instruments was highly significant
in both study groups (p<0.001). All other IOP measures were significantly higher
than those for GAT, except for the Goldmann-correlated IOP (average of the ... Cited by 2 - Related articles - All 5 versions
A Queiros, JM Gonzalez-Meijome, P Fernandes, … - Ophthalmic and Physiological Optics, 2007 - duanesolution.com Results: Intraocular pressure values obtained with the ICare were 14.9 ± 2.8;
14.1 ± 2.5 and 14.5 ± 2.7 mmHg at centre, nasal and temporal corneal
locations, respectively. On average, nasal and temporal IOP readings were ... Cited by 2 - Related articles - Cached - BL Direct - All 5 versions
- ►uv.es [PDF] A Cervino - British Journal of Ophthalmology, 2006 - bjo.bmj.com Goldmann applanation tonometry (GAT) has been the gold standard for intraocular
pressure (IOP) measurement since its appearance in clinical practice almost 50
years ago. 1 Despite being relatively unchallenged, the last few years have ... Cited by 2 - Related articles - BL Direct - All 5 versions
A Sahin, H Basmak, N Yildirim - Journal of Glaucoma, 2008 - journals.lww.com Key Words: central corneal thickness, corneal curvature, intra- ocular pressure,
rebound tonometer, schoolchildren, Tono-pen ... Accurate intraocular pressure
(IOP) measurement is an important step in the diagnosis and management of ... Cited by 1 - Related articles - BL Direct - All 2 versions
GAT While - icaretonometer.com Principle of Perkins The cone surface is applied to the cornea, applanating a
diameter of between 3-4mm, so the surface tension of the tears pulling the cone
towards the eye is approximately equal to the resistance provided by the ... Related articles - View as HTML
A RIMBALZO - otticafisiopatologica.it Gli Autori dichiarano di non avere nessun interesse commerciale con le case
produttrici delle strumentazioni menzionate nel presente articolo. ... AUTORE
CORRISPONDENTE: Dott. Donato Errico Unità Operativa di Oculistica Pia ... Related articles - View as HTML