Scholar Results 1 - 10 of about 17 citing Iliev: Comparison of rebound tonometry with Goldmann applanation tonometry and correlation.... (0.09 sec) 

Assessment of true intraocular pressure: the gap between theory and practical data


E Chihara - Survey of Ophthalmology, 2008 - Elsevier
A precise assessment of the intraocular pressure (IOP) is crucial for diagnosis
and decision making regarding treatment modalities in patients with glaucoma.
Recent epidemiologic studies show that a difference of only 1 mm Hg in the ...
Cited by 9 - Related articles - All 18 versions

Corneal hysteresis but not corneal thickness correlates with optic nerve surface compliance …

- iovs.org
AP Wells, DF Garway-Heath, A Poostchi, T … - Investigative Ophthalmology & Visual Science, 2008 - ARVO
METHODS. This was a prospective experimental study of 100 subjects (38 with
glaucoma, 62 without glaucoma). Data collected included spherical equivalent,
optic disc diameter, central corneal thickness (CCT), axial length, ...
Cited by 7 - Related articles - All 2 versions

Comparison of the ICare® rebound tonometer with the Goldmann applanation tonometer by …


LM Abraham, NCR Epasinghe, D Selva, R … - Eye, 2006 - nature.com
Two tonometrists, experienced with both Goldmann applanation tonometry (GAT) and
ICare® Tonometry (ICT) measured intraocular pressure (IOP), in a masked
fashion, in 100 patients. In another series of 58 patients, ICT was ...
Cited by 7 - Related articles - BL Direct - All 3 versions

New ways to measure intraocular pressure

- duanesolution.com
MK ElMallah, SG Asrani - Current Opinion in Ophthalmology, 2008 - journals.lww.com
Recent findings: The ocular response analyzer provides measurements of corneal
biomechanics, including corneal hysteresis. Intraocular pressure readings from
the ocular response analyzer have correlated well with Goldmann applanation ...
Cited by 6 - Related articles - BL Direct - All 4 versions

Pascal, ICare and Goldmann applanation tonometry-a comparative study


G Johannesson, P Hallberg, A Eklund, C … - Acta Ophthalmologica, 2008 - interscience.wiley.com
It is also possible that your web browser is not configured or not able to
display style sheets. In this case, although the visual presentation will be
degraded, the site should continue to be functional. We recommend using the ...
Cited by 4 - Related articles - All 4 versions

Comparison of the iCare rebound tonometer and the Goldmann applanation tonometer over …


S Munkwitz, A Elkarmouty, EM Hoffmann, N … - Graefe's Archive for Clinical and Experimental …, 2008 - Springer
Abstract Background The aim of this study was to compare the intraocular
pressure (IOP) results measured by the iCare rebound tonometer with those
obtained by the Goldmann applanation tonometer (GAT) over a wide range of ...
Cited by 2 - Related articles - BL Direct - All 3 versions

Accuracy of Goldmann, ocular response analyser, Pascal and TonoPen XL tonometry in …

- duanesolution.com
SP Mollan, JS Wolffsohn, M Nessim, M … - British Journal of Ophthalmology, 2008 - bjo.bmj.com
Results: The difference in IOP values between instruments was highly significant
in both study groups (p<0.001). All other IOP measures were significantly higher
than those for GAT, except for the Goldmann-correlated IOP (average of the ...
Cited by 2 - Related articles - All 5 versions

Technical Note: A comparison of central and peripheral intraocular pressure using rebound …


A Queiros, JM Gonzalez-Meijome, P Fernandes, … - Ophthalmic and Physiological Optics, 2007 - duanesolution.com
Results: Intraocular pressure values obtained with the ICare were 14.9 ± 2.8;
14.1 ± 2.5 and 14.5 ± 2.7 mmHg at centre, nasal and temporal corneal
locations, respectively. On average, nasal and temporal IOP readings were ...
Cited by 2 - Related articles - Cached - BL Direct - All 5 versions

Corneal biomechanics and optic nerve head compliance: corneal hysteresis but not corneal …

- iovs.org [PDF] 
AP Wells, DT Garway-Heath, A Poostchi, T … - Investigative Ophthalmology & Visual Science, 2008 - ARVO
Financial Support This work was supported by the Capital Vision Research Trust
This research has received a proportion of its funding from the Department of
Health's National Institute for Health Research Biomedical Research Centre ...
Cited by 3 - Related articles

Rebound tonometry: new opportunities and limitations of non-invasive determination of …

- uv.es [PDF] 
A Cervino - British Journal of Ophthalmology, 2006 - bjo.bmj.com
Goldmann applanation tonometry (GAT) has been the gold standard for intraocular
pressure (IOP) measurement since its appearance in clinical practice almost 50
years ago. 1 Despite being relatively unchallenged, the last few years have ...
Cited by 2 - Related articles - BL Direct - All 5 versions