Scholar Results 1 - 10 of about 19 citing Lavanya: Comparison of anterior chamber depth measurements using the IOLMaster, scanning.... (0.10 sec) 

Biometry and intraocular lens power calculation

- v2020la.org [PDF] 
AC Lee, MA Qazi, JS Pepose - Current Opinion in Ophthalmology, 2008 - journals.lww.com
Introduction The refractive power of the human eye depends on the power of the
cornea and the lens, the position of the lens, and the length of the eye.
Accurate assessment of these variables is essential in achieving optimal ...
Cited by 10 - Related articles - BL Direct - All 6 versions

Accuracy of cornea and lens biometry using anterior segment optical coherence tomography


MCM Dunne, LN Davies, JS Wolffsohn - Journal of Biomedical Optics, 2007 - link.aip.org
We assess the accuracy of the Visante anterior segment optical coherence
tomographer (AS-OCT) and present improved formulas for measurement of surface
curvature and axial separation. Measurements are made in physical model ...
Cited by 5 - Related articles - BL Direct - All 3 versions

Assessment of anterior segment parameters under photopic and scotopic conditions in …


S Dacosta, G Fernandes, B Rajendran, P … - Indian Journal of Ophthalmology, 2008 - pubmedcentral.nih.gov
One hundred eyes of 100 normal subjects of both sexes, aged 19 to 76 years,
underwent anterior segment evaluation by AS OCT (Visante™ OCT). Central
corneal thickness (CCT), central anterior chamber depth (ACD), pupil ...
Cited by 2 - Related articles - BL Direct - All 5 versions

Anterior ocular biometry using 3-dimensional optical coherence tomography


S Fukuda, K Kawana, Y Yasuno, T Oshika - Ophthalmology, 2009 - Elsevier
The CCT was measured by 4 methods (CAS-OCT, Scheimpflug camera, scanning-slit
topography, and ultrasonic pachymetry), and the ACD was measured by 3 methods
(CAS-OCT, Scheimpflug camera, and scanning-slit topography). The anterior ...
Cited by 1 - Related articles - All 2 versions

Effect of a Suction Device for Femtosecond Laser on Anterior Chamber Depth and …


C Russmann, M Blum, M Reich, M Dick, KS … - journalofrefractivesurgery.com
From Carl Zeiss Meditec AG, Jena (Russmann, Reich, Dick); and the Department of
Ophthalmology, Helios Klinikum Erfurt, Erfurt, Germany (Blum, Kunert). The
project was funded by the Federal Ministry for Education and Research (No. ...
Related articles

Comparison and Evaluation of Ocular Biometry Using a New Noncontact Optical Low- …


K Rohrer, BE Frueh, R Wälti, IA Clemetson, … - Ophthalmology, 2009 - Elsevier
To evaluate a new high-resolution noncontact biometer (Lenstar; Haag-Streit AG,
Koeniz, Switzerland) using optical low-coherence reflectometry and to compare
the clinical measurements with those obtained from the IOLMaster (Carl ...
Related articles - All 2 versions

Anterior Segment Imaging

- axon.es [PDF] 
M Heur, WJ Dupps Jr - Surgery - Springer
Anterior segment imaging has made tremendous strides since the introduction of
slit lamp biomicroscopy.When the slit illumination device [1] of Swedish
ophthalmolo- gist Allvar Gullstrand was combined with Czapski's binocular ...
Related articles - All 2 versions

Comparison of central corneal thickness and anterior chamber depth measurements using …

- nih.gov
M Doors, LPJ Cruysberg, TTJM Berendschot, … - Graefe's Archive for Clinical and Experimental …, 2009 - Springer
Abstract Background The repeatability and interchangeability of imaging devices
measuring central corneal thickness (CCT) and anterior chamber depth (ACD) are
important in the assessment of patients considering refractive surgery. The ...
Related articles - All 3 versions

Anterior Chamber Depth Is Significantly Decreased after Scleral Buckling Surgery


F Goezinne, EC La Heij, TTJM Berendschot, … - Ophthalmology, 2009 - Elsevier
Myopic patients have an increased risk for the development of a rhegmatogenous
retinal detachment (RRD). Currently, myopic patients have the choice to undergo
correction of their refractive error by the implantation of a phakic ...

Phakic Intraocular Lens Implantation for the Correction of Myopia A Report by the …


D Huang, SC Schallhorn, A Sugar, AA Farjo, … - Ophthalmology, 2009 - Elsevier
Two pIOLs have been approved by the US Food and Drug Administration (FDA): one
iris-fixated pIOL and one posterior-chamber IOL. In FDA trials of iris-fixated
pIOLs, uncorrected visual acuity (UCVA) was ≥20/40 in 84% and ≥20/20 in ...