Web Images Videos Maps News Shopping Gmail more »
Sign in
Scholar Home  
  Advanced Scholar Search
Scholar Preferences
Scholar Results 1 - 10 of about 164 citing Kaufman: A pilot study of the continuous glucose monitoring system. (0.10 sec) 

[CITATION] Continuous glucose monitoring: roadmap for 21st century diabetes therapy.

- Free from Publisher
DC Klonoff - Diabetes Care, 2005 - ncbi.nlm.nih.gov
1: Diabetes Care. 2005 May;28(5):1231-9. Continuous glucose monitoring: roadmap
for 21st century diabetes therapy. Klonoff DC. Mills ...
Cited by 167 - Related articles - All 3 versions

Continuous subcutaneous glucose monitoring improved metabolic control in pediatric patients …


J Ludvigsson, R Hanas - Pediatrics, 2003 - Am Acad Pediatrics
Design. We have used Continuous Glucose Monitoring System (CGMS; Medtronic
MiniMed, Northridge, CA) in a controlled crossover study including 27 diabetic
patients aged 12.5 ± 3.3 (mean; standard deviation; range: 5–19) years. ...
Cited by 160 - Related articles - BL Direct - All 5 versions

The continuous glucose monitoring system is useful for detecting unrecognized hypoglycemias …

- diabetesjournals.org
A Chico, P Vidal-Ríos, M Subirà, A Novials - Diabetes Care, 2003 - Am Diabetes Assoc
RESULTS—The CGMS detected unrecognized hypoglycemias in 62.5% of the type 1
diabetic patients and in 46.6% of the type 2 diabetic patients. We found that
73.7% of all events occurred at night. HbA 1c concentrations decreased ...
Cited by 121 - Related articles - BL Direct - All 7 versions

Clinical performance of CGMS in type 1 diabetic patients treated by continuous subcutaneous …

- diabetesjournals.org
B Guerci, M Floriot, P Böhme, D Durain, M … - Diabetes Care, 2003 - Am Diabetes Assoc
RESEARCH DESIGN AND METHODS—The analysis was conducted on 18 type 1 diabetic
patients (not controlled, HbA 1c >7.5%) treated by external pump using insulin
analogs. Each patient received a glucose sensor for 3 days during his/her ...
Cited by 117 - Related articles - BL Direct - All 6 versions

Alarms based on real-time sensor glucose values alert patients to hypo-and hyperglycemia: …


B Bode, K Gross, N Rikalo, S Schwartz, T Wahl … - Diabetes Technology & Therapeutics, 2004 - liebertonline.com
Page 1. DIABETES TECHNOLOGY & THERAPEUTICS Volume 6, Number 2, 2004 © Mary Ann Liebert,
Inc. Alarms Based on Real-Time Sensor Glucose Values Alert ...
Cited by 95 - Related articles - BL Direct - All 4 versions

Performance assessment of the Medtronic-MiniMed Continuous Glucose Monitoring System and …


N Sachedina, JC Pickup - Diabetic medicine, 2003 - interscience.wiley.com
It is also possible that your web browser is not configured or not able to
display style sheets. In this case, although the visual presentation will be
degraded, the site should continue to be functional. We recommend using the ...
Cited by 80 - Related articles - BL Direct - All 5 versions

Use of the GlucoWatch biographer in children with type 1 diabetes


HP Chase, MD Roberts, C Wightman, G … - Pediatrics, 2003 - Am Acad Pediatrics
Methods. Forty children in poor glucose control (glycohemoglobin [HbA1c] >8%)
were randomized to diabetes management with or without glucose monitoring using
the biographer. Conventional glucose monitoring was performed 4 times daily ...
Cited by 76 - Related articles - BL Direct - All 8 versions

Impact of pramlintide on glucose fluctuations and postprandial glucose, glucagon, and …

- diabetesjournals.org
C Levetan, LL Want, C Weyer, SA Strobel, J … - Diabetes Care, 2003 - Am Diabetes Assoc
RESEARCH DESIGN AND METHODS—In this study, 18 patients (16 of whom could be
evaluated) with type 1 diabetes (age 44 ± 11 years, HbA 1c 8.2 ± 1.3% [mean ±
SD]) were given mealtime injections of 30 μg pramlintide tid for 4 weeks ...
Cited by 68 - Related articles - BL Direct - All 6 versions

[PDF] Use of the Continuous Glucose Monitoring System to guide therapy in patients with insulin- …


R Tanenberg, B Bode, W Lane, C Levetan, J … - Mayo Clinic Proceedings, 2004 - mayoclinicproceedings.com
From the Brody School of Medicine, Greenville, NC (RT); Atlanta Diabetes
Associates, Atlanta, Ga (BB); Mountain Diabetes & Endocrine Center, Asheville,
NC (WL); MCP Hospital, Philadelphia, Pa (CL); University of Southern ...
Cited by 67 - Related articles - View as HTML - BL Direct - All 10 versions

Improved metabolic control in diabetic adolescents using the continuous glucose …


P Schaepelynck-Belicar, P Vague, G … - Diabetes and Metabolism, 2003 - Elsevier
Twelve adolescents (mean age: 16.2 ± 3 years) with poorly controlled type 1
diabetes (HbA 1c > 8%) were included in this trial. Mean HbA 1c during the
previous year was 10.1 ± 1.2%. Insulin treatment consisted of 2 or 3 daily ...
Cited by 63 - Related articles - BL Direct - All 3 versions


Result Page: 

1

2

3

4

5

6

7

8

9

10

Next


 


Go to Google Home - About Google - About Google Scholar

©2009 Google