Scholar Results 1 - 10 of about 48 citing Weinstein: Accuracy of the 5-day FreeStyle Navigator continuous glucose monitoring system. (0.09 sec) 

Fully automated closed-loop insulin delivery versus semiautomated hybrid control in pediatric …

- Free from Publisher
SA Weinzimer, GM Steil, KL Swan, J Dziura, … - Diabetes Care, 2008 - Am Diabetes Assoc
OBJECTIVE—The most promising β-cell replacement therapy for children with
type 1 diabetes is a closed-loop artificial pancreas incorporating continuous
glucose sensors and insulin pumps. The Medtronic MiniMed external ...
Cited by 30 - Related articles - BL Direct - All 5 versions

Continuous Glucose Monitoring System in children with type 1 diabetes mellitus: a …


DT Golicki, D Golicka, L Groele, E Pankowska - Diabetologia, 2008 - Springer
Page 1. META-ANALYSIS Continuous Glucose Monitoring System in children with type
1 diabetes mellitus: a systematic review and meta-analysis ...
Cited by 11 - Related articles - BL Direct - All 2 versions

Sensor-augmented pump therapy in type 1 diabetes


SA Weinzimer, WV Tamborlane - Current Opinion in Endocrinology, Diabetes and …, 2008 - journals.lww.com
Purpose of review: Recent developments in technology have ushered in a new era
of managing type 1 diabetes. Continuous glucose monitoring is rapidly becoming
an accepted adjunct to traditional self-monitoring of plasma glucose, and ...
Cited by 10 - Related articles - BL Direct - All 2 versions

[PDF] Continuous glucose sensors: continuing questions about clinical accuracy


WL Clarke, BP Kovatchev - J Diabetes Sci Technol, 2007 - journalofdst.org
Abbreviations: (ARD) absolute R deviation, (BG) blood glucose, (CG-EGA)
continuous glucose error-grid analysis, (CGS) continuous glucose sensors, (EGA)
error grid analysis, (FDA) Food and Drug Administration, (IG) interstitial ...
Cited by 9 - Related articles - View as HTML - All 2 versions

Characterizing glucose exposure for individuals with normal glucose tolerance using …


RS Mazze, E Strock, D Wesley, S Borgman, B … - Diabetes Technology & Therapeutics, 2008 - liebertonline.com
ROGER S. MAZZE, Ph.D., 1,2 ELLIE STROCK, ARNP-BC, CDE, 1 DAVID WESLEY, BS, 1
... SARAH BORGMAN, BSN, 1 BLAINE MORGAN, MS, 1 RICHARD BERGENSTAL, MD, 1,2 ...
Background: Efforts to mimic euglycemia depend upon targets from ...
Cited by 10 - Related articles - BL Direct - All 3 versions

How to Assess and Compare the Accuracy of Continuous Glucose Monitors?


IME Wentholt, AAM Hart, JBL Hoekstra, JH … - Diabetes Technology & Therapeutics, 2008 - liebertonline.com
Continuous glucose monitors may be valuable tools for improving glycemic control
and avoid- ing hypoglycemia in patients with diabetes. To this goal, sensor
readings must adequately re- flect the actual blood glucose, emphasizing ...
Cited by 5 - Related articles - BL Direct - All 3 versions

The accuracy and efficacy of real-time continuous glucose monitoring sensor in patients with …


J Mastrototaro, J Shin, A Marcus, G Sulur - Diabetes technology & therapeutics, 2008 - liebertonline.com
DIABETES TECHNOLOGY & THERAPEUTICS Volume 10, Number 5, 2008 © Mary Ann
Liebert, Inc. DOI: 10.1089/dia.2007.0291 ... The Accuracy and Efficacy of
Real-Time ... John Mastrototaro, Ph.D., John Shin, Ph.D., Alan Marcus, ...
Cited by 5 - Related articles - All 4 versions

Comparison of accuracy and safety of the SEVEN and the Navigator continuous glucose …


SK Garg, J Smith, C Beatson, B Lopez-Baca, M … - Diabetes Technology & Therapeutics, 2009 - liebertonline.com
Page 1. DIABETES TECHNOLOGY & THERAPEUTICS Volume 11, Number 2, 2009 © Mary
Ann Liebert, Inc. DOI: 10.1089/dia.2008.0109 Comparison ...
Cited by 4 - Related articles - All 2 versions

Clinical use of real-time continuous glucose monitoring


T Battelino, J Bolinder - Current Diabetes Reviews, 2008 - ingentaconnect.com
Abstract: Maintaining near-normal glycaemia in all patients with diabetes
mellitus (DM) has become a standard and a well accepted recommendation.
Unfortunately, most people with DM do not achieve this clinical goal ...
Cited by 4 - Related articles - All 2 versions

Evaluating clinical accuracy of continuous glucose monitoring systems: continuous glucose- …


WL Clarke, S Anderson, B Kovatchev - Current Diabetes Reviews, 2008 - ingentaconnect.com
Abstract: Continuous Glucose Sensors (CGS) generate rich and informative
continuous data streams which have the po- tential to improve the glycemic
condition of the patient with diabetes. Such data are critical to the ...
Cited by 4 - Related articles - All 2 versions