Web Images Videos Maps News Shopping Gmail more »
Sign in
Scholar Home  
  Advanced Scholar Search
Scholar Preferences
Scholar Results 1 - 10 of about 40 citing Shapiro: A comparison of accuracy and estimated cost of methods for home blood glucose monitoring.. (0.08 sec) 

Intensive attention improves glycaemic control in insulin-dependent diabetes …

- nih.gov [PDF] 
R Worth, PD Home, DG Johnston, J Anderson, L … - British Medical Journal, 1982 - bmj.com
Page 1. doi:10.1136/bmj.285.6350.1233 1982;285;1233-1240 Br Med J (Clin Res Ed)
Appleton, C Binder and KG Alberti R Worth, PD Home, DG Johnston, J Anderson, L
Ashworth, JM Burrin, D monitoring: results of a controlled trial. ...
Cited by 90 - Related articles - All 4 versions

Glucose measurement in patients with diabetes mellitus with dermal interstitial fluid


JP Bantle, W Thomas - The Journal of laboratory and clinical medicine, 1997 - Elsevier
Glucose measurement in patients with diabetes mellitus with dermal interstitial fluid JOHN P.
BANTLE and WILLIAM THOMAS MINNEAPOLIS, MINNESOTA Although measurement of capillary
blood glucose remains the standard method of selfmonitoring for persons with diabetes ...
Cited by 87 - Related articles - BL Direct - All 7 versions

[PDF] Evaluation of bedside testing options for the critical care unit


GP Zaloga - Chest, 1990 - Am Coll Chest Phys
Page 1. DOI 10.1378/chest.97.5_Supplement.185S 1990;97;185S-190S Chest Gary
P. Zaloga Critical Care Unit Evaluation of Bedside Testing Options for the
http://www.chestjournal.org/content/97/5_Supplement/185S services ...
Cited by 56 - Related articles - All 6 versions

New whole blood analyzers and their impact on cardiac and critical care


GJ Kost, MJ McQueen - Critical reviews in clinical laboratory …, 1993 - informahealthcare.com
School of Medicine, University of California, Davis ... * Comspondence: Gerald J. Kost. MD,
PhD., Medical Pathology, University of California, Davis, Davis, CA 95616 ... ABSTRACT: Miniaturized
whole blood biosensors, patient-focused hospitals, and rising expecta- tions of patients ...
Cited by 40 - Related articles - All 5 versions

Evaluation of the quality of bedside monitoring of the blood glucose level in a …

- nih.gov [PDF] 
C Ting, AA Nanji - CMAJ: Canadian Medical Association Journal, 1988 - pubmedcentral.nih.gov
We evaluated the precision and accuracy of monitoring of the blood glucose level in the laboratory
andat the bedside with one of four glucose meters by an experienced operator and by 39 nurses
in a teaching hospital. For precision studies aqueous quality control materials were used. ...
Cited by 26 - Related articles - All 12 versions

Self-Monitoring of Blood Glucose Levels in Diabetes: Principles and Practice


M Bergman, P Felig - Archives of internal medicine, 1984 - archinte.highwire.org
\s=b\Self-monitoring of blood glucose levels has become popu- lar due to the limitations in the
use of urine testing for assessing the status of diabetes control. Furthermore, the recent emphasis
on the importance of diabetes regulation entails that patients tailor the insulin doses ...
Cited by 14 - Related articles - All 5 versions

Self-monitoring of the blood glucose level: potential sources of inaccuracy

- nih.gov [PDF] 
B Rasaiah - Canadian Medical Association Journal, 1985 - pubmedcentral.nih.gov
2. Norman PS: In-vivo methods of study of allergy (chap 16). In Middleton E Jr, Reed CE, Ellis
EF (eds): Allergy Principles and Practice, 2nd ed, Mosby, St Louis, 1983: 295-302 ... 3. Canadian
Paediatric Society, Subconimittee of the Allergy Section: Skin testing for allergy in ...
Cited by 12 - Related articles - All 5 versions

[CITATION] Effects of social demand on reports of self-monitored blood glucose in adolescents …


AM Delamater, SM Kurtz, NH White, … - Journal of Applied …, 1988 - Blackwell Publishing Ltd
Cited by 12 - Related articles

Comparison of various methods of blood sugar screening in newborn infants


AJ Herrera, YH Hsiang - The Journal of Pediatrics, 1983 - Elsevier
We evaluated two reagent strips, Dextrostix and Chemstrip-BG, and the reflectance meter
technique, Stat-tek Photometer, in the screening of blood sugar values in newborn infants at
high risk and compared them with laboratory glucose determination using an automatic ...
Cited by 11 - Related articles - All 3 versions

Evaluation of two reagent strips and three reflectance meters for rapid …


RJ Joseph, K Allyson, TK Graves, MJ Rondeau, … - J Vet Intern …, 1987 - interscience.wiley.com
We evaluated three reflectance meters (Accu-Chek II, Glucometer II, and Glucoscan 2000) and
two reagent strips (Chemstrip bG and Glucostix) for accuracy and precision in determining blood
glucose concentrations in the dog. To evaluate accuracy, we compared results of blood ...
Cited by 12 - Related articles - All 3 versions


Result Page: 

1

2

3

4

Next


 


Go to Google Home - About Google - About Google Scholar