- ►angrylapdog.com AE Epstein, JP DiMarco, KA Ellenbogen, NA … - Heart Rhythm, 2008 - Elsevier It is important that the medical profession play a significant role in
critically evaluating the use of diagnostic procedures and therapies as they are
introduced and tested in the detection, management, or prevention of ... Cited by 266 - Related articles - All 29 versions
- ►onlinejacc.org MD Carlson, J Ip, J Messenger, S Beau, S … - Journal of the American College of Cardiology, 2003 - Elsevier The Atrial Dynamic Overdrive Pacing Trial (ADOPT) was a single blind,
randomized, controlled study to evaluate the efficacy and safety of the atrial
fibrillation (AF) Suppression Algorithm (St. Jude Medical Cardiac Rhythm ... Cited by 141 - Related articles - BL Direct - All 11 versions
HH Asada, P Shaltis, A Reisner, S Rhee, RC … - IEEE Engineering in Medicine and Biology Magazine, 2003 - ieeexplore.ieee.org Abstract We address both technical and clinical issues of wearable biosensors
(WBS). First, design concepts of a WBS are presented, with emphasis on the ring
sensor developed by the author's group at MIT. The ring sensor is an ... Cited by 91 - Related articles - BL Direct - All 4 versions
JM Mangrum, JP DiMarco - The New England journal of medicine, 2000 - nejm.highwire.org Cardiac output is the left ventricular forward stroke volume multiplied by the
heart rate. Patients with bradycardia may be asymptomatic if changes in stroke
volume compensate for the decrease in heart rate. In asymptomatic persons, ... Cited by 75 - Related articles - BL Direct - All 5 versions
JA Reiffel, R Schwarzberg, M Murry - The American journal of cardiology, 2005 - Elsevier To determine the relative yields of Holter monitoring (HM), memory loop
recording (MLR), and autotriggered MLR (AT-MLR), we retrospectively interrogated
the very large database of Lifewatch (a Card Guard company and a commercial ... Cited by 39 - Related articles - All 7 versions
A Schuchert, R Maas, C Kretzschmar, G … - Pacing and Clinical Electrophysiology, 2003 - interscience.wiley.com It is also possible that your web browser is not configured or not able to
display style sheets. In this case, although the visual presentation will be
degraded, the site should continue to be functional. We recommend using the ... Cited by 35 - Related articles - BL Direct - All 4 versions
JL Schnipper, WN Kapoor - Medical Clinics of North America, 2001 - Elsevier Syncope is a symptom, not a disease. The potential causes of syncope are myriad
and range from the fairly benign to the potentially life-threatening. To rule
out the more dangerous causes, including cardiac arrhythmias, patients ... Cited by 33 - Related articles - BL Direct - All 11 versions
C Bell, TC Task Force on Preventive Health … - The Canadian Journal of Neurological Sciences, 2000 - CJNS From the Department of Medicine, University of Toronto, Institute of Medical
Science, Program in Clinical Epidemiology and Health Services Research (CB) and
the Department of Medicine, University of Toronto, Division of General ... Cited by 16 - Related articles - BL Direct - All 4 versions
- ►onlinejacc.org [PDF] F Giada, M Gulizia, M Francese, F Croci, L … - Journal of the American College of Cardiology, 2007 - Elsevier The aim of the study was to compare the diagnostic yield and the costs of
implantable loop recorder (ILR) with those of the conventional strategy in
patients with unexplained palpitations. ... In patients with unexplained ... Cited by 14 - Related articles - BL Direct - All 22 versions
- ►oxfordjournals.org F Enseleit, F Duru - Europace, 2006 - Eur Heart Rhythm Assoc Ambulatory electrocardiographic (AECG) monitoring is an essential tool in the
diagnostic evaluation of patients with cardiac arrhythmias. Recent advances in
solid-state technology have improved the quality of the ECG signals and new ... Cited by 15 - Related articles - BL Direct - All 4 versions