MM Wright, AL Grajewski - British Journal of Ophthalmology, 1997 - bjo.bmj.com RESULTS The difference between the manometer (actual pressure) and the Goldmann
tonometer ranged from −19 to + 9 mm Hg (mean (SD) overestimation 2.6 (5.8) mm
Hg). The pneumatonometer error ranged from −27.5 to + 5.5 mm Hg (mean ... Cited by 1 - Related articles - BL Direct - All 7 versions
PF Olson, MB McDonald, TP Werblin, HE … - Archives of Ophthalmology, 1983 - archopht.highwire.org \s=b\ New forms of refractive surgery result in corneas that are nearly doubled
in thickness. To test the reliability of standard instrumentation for the mea-
surement of intraocular pressure in such eyes, the MacKay-Marg tonometer ... Cited by 5 - Related articles - All 3 versions
EJ Higginbotham - American journal of ophthalmology, 1988 - ncbi.nlm.nih.gov 1: Am J Ophthalmol. 1988 Jan 15;105(1):101. Clinical evaluation of the Oculab
Tono-Pen. Higginbotham EJ. Publication Types: Letter. ... Cited by 6 - Related articles
T Christoffersen, K Holtedahl, T Fors, U … - Acta ophthalmologica - interscience.wiley.com It is also possible that your web browser is not configured or not able to
display style sheets. In this case, although the visual presentation will be
degraded, the site should continue to be functional. We recommend using the ... Cited by 6 - Related articles - BL Direct - All 3 versions
AK Jain, JS Saini, R Gupta - Indian Journal of Ophthalmology, 2000 - Medknow PURPOSE: Clinical comparison of intraocular pressure (IOP) measured with the
Goldmann applanation tonometer (GAT), the ProTon tonometer (PT), and the Schiotz
tonometer (ST), in normal eyes, eyes with scarred corneas and ... Cited by 7 - Related articles - Cached - BL Direct - All 3 versions
VJ Rao, L Gnanaraj, KW Mitchell, FC … - Cornea, 2001 - journals.lww.com Cornea. Wolters Kluwer Health | Lippincott Williams & Wilkins. All Issues. ... Cited by 21 - Related articles - BL Direct - All 2 versions
- ►iovs.org [PDF] JK Kristinsson, H Fridriksdottir, S Thorisdottir … - Investigative ophthalmology & visual science, 1996 - ARVO Tono-Pen versus manometry in humans shortly after deadi. AmJ Ophthalmol. 1988;
105:678-682. 4. Kao SF, Lichter PR, Bergstrom TJ, Rowe S, Musch DC. Clinical
comparison of the Oculab Tono-Pen to the Goldmann applanation tonometer. ... Cited by 38 - Related articles - BL Direct - All 4 versions
- ►iovs.org [PDF] JA Peterson, JA Kiland, MA Croft, PL Kaufman - Investigative ophthalmology & visual science, 1996 - ARVO Purpose. In living cynomolgus monkey eyes, the authors compared manometrically
set and measured intraocu- lar pressure (IOP) with simultaneous IOP readings ob-
tained with the Tono-Pen (TP), a handheld applana- tion tonometer based on ... Cited by 19 - Related articles - BL Direct - All 3 versions
T Christoffersen, T Fors, U Ringberg, K … - Acta ophthalmologica - interscience.wiley.com Abstract. Intraocular pressure was measured in 132 consecutive patients over the
age of 20 in a general pratice with two general practitioners (GP). Tono-Pen
tonometry was compared to Goldmann applanation tonometry in a masked, ... Cited by 19 - Related articles - BL Direct - All 3 versions
[CITATION] Cowan, C, Pollack, IP: Tonometry on eyes with abnormal corneas