Web Images Videos Maps News Shopping Gmail more »
Sign in
Scholar Home  
  Advanced Scholar Search
Scholar Preferences
Scholar Results 1 - 10 of about 101 related to Kogure: Agreement between frequency doubling perimetry and static perimetry in eyes with.... (0.10 sec) 

Agreement between frequency doubling perimetry and static perimetry in eyes with high …

- bmj.com
S Kogure, Y Toda, D Crabb, K Kashiwagi, FW … - British Medical Journal, 2003 - bjo.bmj.com
Methods: 72 eyes of 36 patients, who had two or more experiences with the
Humphrey field analyser (HFA) program C30-2, were examined with the screening
C-20-1 program of FDT. The result of FDT at each of the 17 stimulus points ...
Cited by 10 - Related articles - BL Direct - All 8 versions

[PDF] Comparison of detectability of visual field abnormality by frequency doubling technology …


N Horikoshi, M Osako, Y Tamura, T Okano, M … - Jpn J Ophthalmol, 2001 - nichigan.or.jp
Noriko Horikoshi,* Masahiro Osako,* Yoko Tamura,* Tadashi Okano* and Masahiko
Usui† ... *Department of Ophthalmology, Kasumigaura Hospital, Tokyo Medical
University, Tokyo, Japan; †Department of Ophthalmology, Tokyo Medical ...
Cited by 9 - Related articles - BL Direct - All 8 versions

Correlation between optic disc tomography and frequency doubling technology in glaucoma …


BS Ko, CY Kim, YJ Hong - J Korean Ophthalmol Soc, 2003 - koreamed.org
PURPOSE: To evaluate the relationship between results obtained by Heidelberg
Retina Tomography (HRT) and frequency-doubling technology (FDT) in glaucoma
suspect. METHODS: A total of 24 patients with glaucoma suspect were ...
Cited by 2 - Related articles - Cached - All 3 versions

Frequency doubling technology perimetry with the Humphrey Matrix 30-2 test


P Brusini, ML Salvetat, M Zeppieri, L Parisi - Journal of Glaucoma, 2006 - journals.lww.com
Skip Navigation Links Home > April 2006 - Volume 15 - Issue 2 > Frequency
Doubling Technology Perimetry With the Humphrey Ma... ... The authors have
stated that they have no proprietary interest in any of the materials used ...
Cited by 26 - Related articles - BL Direct - All 2 versions

Frequency doubling technology and high-pass resolution perimetry in glaucoma and ocular …


L Kalaboukhova, B Lindblom - Acta Ophthalmologica Scandinavica, 2003 - interscience.wiley.com
It is also possible that your web browser is not configured or not able to
display style sheets. In this case, although the visual presentation will be
degraded, the site should continue to be functional. We recommend using the ...
Cited by 11 - Related articles - BL Direct - All 4 versions

Learning effect, normal range, and test-retest variability of Frequency Doubling Perimetry …


GP Heeg, TL Ponsioen, NM Jansonius - Ophthalmic and Physiological Optics, 2003 - interscience.wiley.com
The learning effect for several different Frequency Doubling Perimetry
parameters was studied in full threshold mode in a large group of patients (n =
342) of various ages, with and without perimetric experience, and with and ...
Cited by 14 - Related articles - BL Direct - All 4 versions

Relationship between indices of Humphrey perimetry and frequency doubling technology …


A Fukushima, M Shirakashi, K Yaoeda, S … - Journal of Glaucoma, 2004 - journals.lww.com
Methods: This study included 200 eyes of 200 patients with primary open-angle
glaucoma or normal-tension glaucoma. The eyes were classified into the early and
later stages by the median value (-4.51 dB) (Classification 1; n = 100 and ...
Cited by 7 - Related articles - BL Direct - All 2 versions

Comparison of frequency doubling perimetry and standard achromatic computerized …


S Serguhn, D Spiegel - Graefe's Archive for Clinical and Experimental …, 2001 - Springer
Abstract Purpose: To evaluate the reproducibility and efficacy of fre-
quency-doubling perimetry (FDP), a new perimetric method for the de- tection of
functional glaucomatous damage. Methods: Thirty-four glaucomatous eyes of ...
Cited by 17 - Related articles - BL Direct - All 4 versions

Comparison of clinical optic disc assessment with tests of early visual field loss


JA Landers, I Goldberg, SL Graham - Clinical &# 38; Experimental Ophthalmology, 2002 - ingentaconnect.com
Purpose: Clinical optic disc assessment may identify glaucomatous optic
neuropathy prior to a patient developing visual field abnormalities on
achromatic automated perimetry (AAP). Tests targeting axons that are ...
Cited by 8 - Related articles - BL Direct - All 2 versions

Staging of functional damage in glaucoma using frequency doubling technology


P Brusini, C Tosoni - Journal of Glaucoma, 2003 - journals.lww.com
Staging of Functional Damage in Glaucoma Using Frequency ... Paolo Brusini, MD,
and Claudia Tosoni, MD ... Department of Ophthalmology, Santa Maria della
Misericordia Hospital, Udine, Italy ... Purpose: To evaluate three new ...
Cited by 8 - Related articles - BL Direct - All 2 versions


Result Page: 

1

2

3

4

5

6

7

8

9

10

Next


 


Go to Google Home - About Google - About Google Scholar

©2009 Google