- ►nih.gov - Free from Publisher AC Browning, A Bhan, AP Rotchford, S Shah, … - British Journal of Ophthalmology, 2004 - bjo.bmj.com Results: Mean IOP measurements in all three patient groups were significantly
higher when measured by OBF pneumotonometer. Linear regression analysis showed
that patients with FED had a significant increase in IOP with increasing ... Cited by 25 - Related articles - BL Direct - All 10 versions
Z Ozbek, EJ Cohen, KM Hammersmith, CJ … - Cornea, 2006 - journals.lww.com Skip Navigation Links Home > September 2006 - Volume 25 - Issue 8 > Dynamic
Contour Tonometry: A New Way to Assess Intraocular P... ... From the Cornea
Service, Wills Eye Hospital, Jefferson Medical College of Thomas Jefferson ... Cited by 10 - Related articles - BL Direct - All 4 versions
S Patel, JM McLaughlin - Ophthalmic and Physiological Optics, 1999 - interscience.wiley.com Methods: 22 keratoconus (category I: six female sixteen male, average age 27.0
range 12–47) and 19 post-keratoplasty (category II: ten female nine male
average age 34.6 range 16–54) patients without other anterior segment ... Cited by 18 - Related articles - BL Direct - All 5 versions
- ►nih.gov ME Iliev, D Goldblum, K Katsoulis, C Amstutz, … - British Journal of Ophthalmology, 2006 - bjo.bmj.com Results: RT was well tolerated and safe. Intraocular pressure (IOP) ranged
between 6 mm Hg and 48 mm Hg. No different trends were found between the groups.
RT tended to give slightly higher readings: n = 101, mean difference 1.0 ... Cited by 17 - Related articles - BL Direct - All 5 versions
C Garcia-Resua, JM GONZÁLEZ-MEIJOME, … - Optometry & Vision Science, 2006 - journals.lww.com Purpose. The ICare (Tiolat Oy, Helsinki, Finland) is a new portable tonometer
that measures intraocular pressure (IOP) with a new rebound method, in which a
very light probe is used to make momentary contact with the cornea in slow ... Cited by 26 - Related articles - BL Direct - All 5 versions
H Esgin, ML Alimgil, S Erda - European journal of ophtalmology, 1998 - cat.inist.fr Purpose. To compare the IOP readings of an ocular blood flow(OBF) tonograph(OBF
Labs UK Ltd) with Goldmann applanation tonometry. Methods. 194 patients were
studied. In group 1, the software version 8. 2 of the OBF tonograph was ... Cited by 9 - Related articles - BL Direct - All 2 versions
- ►nih.gov - Free from Publisher A Kotecha, ET White, JM Shewry, DF Garway … - British Journal of Ophthalmology, 2005 - bjo.bmj.com Aims: To establish the effects of central corneal thickness (CCT) on intraocular
pressure (IOP) measured with a prototype Pascal dynamic contour tonometer (DCT),
to evaluate the effect of CCT and age on the agreement between IOP measured ... Cited by 77 - Related articles - BL Direct - All 10 versions
- ►bmj.com [PDF] O Geyer, Y Mayron, A Loewenstein, M … - British Medical Journal, 1992 - bjo.bmj.com Page 1. doi:10.1136/bjo.76.9.538 1992;76;538-540 Br. J. Ophthalmol. O Geyer,
Y Mayron, A Loewenstein, M Neudorfer, L Rothkoff and M Lazar ... Cited by 32 - Related articles - All 7 versions
- ►uminho.pt [PDF] JM Gonzalez-Meijome, J Jorge, A Queiros, P … - British Journal of Ophthalmology, 2006 - bjo.bmj.com Results: A high correlation was found between the central and peripheral IOP
readings, with the central readings being higher than the peripheral ones.
Higher IOP values for the central location were found in the younger ... Cited by 10 - Related articles - BL Direct - All 8 versions
- ►bon.de [PDF] P Brusini, ML Salvetat, M Zeppieri, C Tosoni, L … - Journal of Glaucoma, 2006 - journals.lww.com Glaucoma is a major cause of blindness in the Western countries.1 It is well
known that the major risk factors in the progression of glaucoma include
increased ... Copyright r 2006 by Lippincott Williams & Wilkins Cited by 23 - Related articles - All 3 versions