- ►nih.gov - Free from Publisher A Kotecha, ET White, JM Shewry, DF Garway … - British Journal of Ophthalmology, 2005 - bjo.bmj.com Aims: To establish the effects of central corneal thickness (CCT) on intraocular
pressure (IOP) measured with a prototype Pascal dynamic contour tonometer (DCT),
to evaluate the effect of CCT and age on the agreement between IOP measured ... Cited by 77 - Related articles - BL Direct - All 10 versions
E Schneider, F Grehn - Journal of Glaucoma, 2006 - journals.lww.com Results: A clear correlation between dynamic contour tonometry and Goldmann
applanation tonometry was found (r = 0.693; P , 0.001). Dynamic contour
tonometry generally resulted in higher intraocular pressure measurements ... Cited by 65 - Related articles - All 7 versions
- ►iovs.org C Kaufmann, LM Bachmann, MA Thiel - Investigative ophthalmology & visual science, 2004 - ARVO RESULTS. There was a high concordance between the IOP readings obtained by DCT
and GAT. However, IOP readings were consistently higher with DCT than with GAT
(median difference: +1.7 mm Hg, interquartile range [25th–75th ... Cited by 111 - Related articles - BL Direct - All 3 versions
A Doyle, Y Lachkar - Journal of Glaucoma, 2005 - journals.lww.com Journal of Glaucoma. Wolters Kluwer Health | Lippincott
Williams & Wilkins. All Issues. ... Cited by 57 - Related articles - BL Direct - All 2 versions
C Kniestedt, S Lin, J Choe, A Bostrom, M Nee … - Archives of Ophthalmology, 2005 - archopht.highwire.org You are seeing this message because your Web browser does not support basic Web
standards. Find out more about why this message is appearing and what you can do
to make your experience on this site better. ... Add to CiteULike Add to ... Cited by 60 - Related articles - BL Direct - All 5 versions
M Pache, S Wilmsmeyer, S Lautebach, J Funk - Graefe's Archive for Clinical and Experimental …, 2005 - Springer Abstract Background: Various sources of error, including central corneal
thickness (CCT) and struc- tural corneal rigidity, have been proposed for
Goldmann applanation tonometry (GAT). The Pascal dy- namic contour ... Cited by 55 - Related articles - BL Direct - All 2 versions
- ►adaptltda.com.br [PDF] HE Kanngiesser, C Kniestedt, YCA Robert - Journal of glaucoma, 2005 - journals.lww.com Results: A concave contact surface with a radius of curvature of 10.5 mm creates
a distribution of forces between the central contour matching area of the tip
and the cornea that equals the forces gener- ated by the internal pressure ... Cited by 69 - Related articles - BL Direct - All 7 versions
JYF Ku, HV Danesh-Meyer, JP Craig, GD … - Eye, 2005 - nature.com IOP measured by the two instruments correlated significantly (r=0.77; P<0.0001).
IOP measured by GAT correlated strongly with CCT (r=0.37, P=0.0001) whereas the
relationship between IOP measured by PDCT and CCT approached significance ... Cited by 42 - Related articles - BL Direct - All 4 versions
BA Kamppeter, JB Jonas - American journal of ophthalmology, 2005 - Elsevier Mean dynamic contour tonometric measurements (18.71 ± 5.90 mm Hg) were
significantly (P < .001) higher than mean applanation tonometric values (16.98
± 5.86 mm Hg), correlating significantly with each other (r 2 = .905, P < ... Cited by 36 - Related articles - All 15 versions
DS Siganos, GI Papastergiou, C Moedas - Journal of Cataract & Refractive Surgery, 2004 - Elsevier Results: Preoperatively, central corneal thickness (CCT) correlated with GAT and
NCT measurements but not with PDCT measurements. After LASIK, the mean reduction
in CCT ranged from −3.0 to −171.0 μm (median 78 μm). The mean GAT ... Cited by 91 - Related articles - All 8 versions