A comparison of four methods of tonometry: method agreement and interobserver variability


PA Tonnu, T Ho, K Sharma, E White, C Bunce … - British Journal of Ophthalmology, 2005 - bjo.bmj.com
Methods: IOP was measured with the Goldmann applanation tonometer (GAT),
Tono-Pen XL, ocular blood flow tonograph (OBF), and Canon TX-10 non-contact
tonometer (NCT) in a randomised order in one eye of each of 105 patients ...
Cited by 42 - Related articles - All 8 versions

Clinical comparison of the Keeler Pulsair 3000 with Goldmann applanation tonometry

- bmj.com
VA Parker, J Herrtage, NJC Sarkies - British Medical Journal, 2001 - bjo.bmj.com
The Keeler Pulsair 3000 became available in November 1998 following a lengthy
development programme to improve upon the Pulsair 2000. Improvements include an
air delivery system that accurately controls the amount of air delivered to ...
Cited by 13 - Related articles - BL Direct - All 7 versions

[PDF] Clinical performance of non-contact tonometry by Reichert AT550 (R) in glaucomatous …


J Jorge, JM Gonzalez-Meijome, JA Diaz-Rey, … - Ophthalmic and Physiological Optics, 2003 - reichertoi.com
Abstract Measuring intraocular pressure (IOP) by non-contact tonometry (NCT) has
been demonstrated to be a valid and reliable technique to be used in primary eye
care; it is easier to use, it does not transmit infectious diseases, and it ...
Cited by 21 - Related articles - View as HTML - BL Direct - All 5 versions

[PDF] Clinical performance of the Reichert AT550: a new non-contact tonometer


J Jorge, JA Diaz-Rey, JM Gonzalez-Meijome, … - Ophthalmic and Physiological Optics, 2002 - reichertoi.com
Abstract The aim of the present study was to assess the level of accuracy for
measurements of intra-ocular pressure (IOP) obtained with a new non-contact
tonometer (NCT) the Reichert AT550Ò. Measure- ments were compared against ...
Cited by 23 - Related articles - View as HTML - BL Direct - All 6 versions

The influence of central corneal thickness and age on intraocular pressure measured by …


PA Tonnu, T Ho, T Newson, A El Sheikh, K … - British Journal of Ophthalmology, 2005 - bjo.bmj.com
Results: A significant association between measured IOP and CCT was found with
each instrument. The change in measured IOP for a 10 μm increase in CCT was
0.28, 0.31, 0.38, and 0.46 for the GAT, Tono-Pen, OBF, and NCT, ...
Cited by 74 - Related articles - All 9 versions

Varying effects of corneal thickness on intraocular pressure measurements with different …


YC Ko, CJ Liu, WM Hsu - Eye, 2004 - nature.com
Ultrasound pachymetry and tonometry were performed on 170 eyes. Using the
corrected GAT values that took CCT into account as the standard, we calculated
the NCT and OBFT measurement errors related to the CCT variable by a linear ...
Cited by 40 - Related articles - All 3 versions

Clinical comparison of the XPERTtm non-contact tonometer and the conventional Goldmann …


MK Hansen - Acta Ophthalmologica Scandinavica, 1995 - interscience.wiley.com
It is also possible that your web browser is not configured or not able to
display style sheets. In this case, although the visual presentation will be
degraded, the site should continue to be functional. We recommend using the ...
Cited by 21 - Related articles - All 2 versions

Effect of corneal parameters on measurements using the pulsatile ocular blood flow …


P Gunvant, M Baskaran, L Vijaya, IS Joseph, … - British Journal of Ophthalmology, 2004 - bjo.bmj.com
Results: The intraocular pressure measurements obtained with both the Goldmann
applanation tonometer and the pulsatile ocular blood flow tonograph varied with
central corneal thickness and mean keratometric reading. Intraocular ...
Cited by 37 - Related articles - BL Direct - All 9 versions

Assessment of the accuracy and reliability of the Topcon CT80 non-contact tonometer


KCO PhD - Clinical and Experimental Optometry - interscience.wiley.com
Methods: The accuracy of the Topcon CT 80 non-contact tonometer was assessed by
comparing its IOP assessments with those of the Goldmann applanation tonometer,
on 60 right eyes of young healthy subjects with normal intraocular ...
Cited by 7 - Related articles - BL Direct - All 3 versions

A comparison of intraocular pressure measurements with the XPERT noncontact tonometer …


KS Popovich, MB Shields - Journal of Glaucoma, 1997 - journals.lww.com
INTRAOCULAR PRESSURE MEASUREMENTS 45 electromechanically brakes the air pulse
pump. The force required to produce applanation is calculated and con- verted to
ЮР, based on an internal calibration system that is derived from a ...
Cited by 17 - Related articles - BL Direct - All 2 versions