- ►nih.gov P Fogagnolo, L Rossetti, F Mazzolani, N … - British Journal of Ophthalmology, 2006 - bjo.bmj.com Methods: 30 patients with primary open angle glaucoma were hospitalised and
underwent circadian evaluations (at 8 pm, midnight, 4 am, 8 am, noon, and 4 pm)
of supine and sitting IOP, respectively, measured using a Perkins and a ... Cited by 13 - Related articles - BL Direct - All 7 versions
- ►duanesolution.com KE Hamilton, DC Pye, S Aggarwala, S Evian, … - Journal of Glaucoma, 2007 - journals.lww.com Reprints: David Cecil Pye, M. Optom, School of Optometry and Vision Science,
Level 1, North Wing, Rupert Myers Building, University of New South Wales,
Sydney NSW 2052, Australia (e-mail: d.pye@unsw.edu.au). Cited by 17 - Related articles - BL Direct - All 4 versions
- ►iovs.org T Kida, JHK Liu, RN Weinreb - Investigative ophthalmology & visual science, 2006 - ARVO RESULTS. There were consistent 24-hour variations of CCT and IOP for the group.
Nocturnal mean CCT and nocturnal mean IOP were significantly higher than the
diurnal mean CCT and diurnal mean IOP, respectively. The peak CCT occurred ... Cited by 25 - Related articles - BL Direct - All 3 versions
R Sihota, R Saxena, M Gogoi, A Sood, V … - Indian Journal of Ophthalmology, 2005 - Medknow The pathophysiology of glaucoma is unclear. Intraocular pressure (IOP) is easily
measurable and only treatable risk factor for the prevention of progressive
glaucomatous field defects. Normal IOP varies with age, sex, time of day, ... Cited by 7 - Related articles - Cached - BL Direct - All 5 versions
HM Yun, P Fu, JS Yuan, B Zhang, XX Li - Zhonghua yi xue za zhi, 2006 - ncbi.nlm.nih.gov OBJECTIVE: To observe the diurnal variations of intraocular pressure (IOP)
measured with dynamic contour tonometer (DCT) in primary open angle glaucoma
(POAG) patients, normal tension glaucoma (NTG) patients, and healthy ... Cited by 2 - Related articles - BL Direct
S Mosaed, WD Chamberlain, JHK Liu, FA … - Journal of Glaucoma, 2008 - journals.lww.com Sameh Mosaed, MD,* Winston Douglas Chamberlain, MD, PhD,* John HK Liu, PhD,w
Felipe A. Medeiros, MD, PhD,w and Robert N. Weinreb, MDw ... Purpose: To
evaluate the association between office-hour central corneal thickness ... Cited by 3 - Related articles - BL Direct - All 2 versions
- ►nih.gov T Kida, JHK Liu, RN Weinreb - American journal of ophthalmology, 2008 - Elsevier Variations in 24-hour corneal hysteresis and corneal resistance factor were not
significant in the older subjects, but there were time-dependent variations in
CCT and IOP. The nocturnal CCT was thicker than the diurnal CCT, but the ... Cited by 5 - Related articles - All 12 versions
S Shah, C Spedding, R Bhojwani, J Kwartz, … - Ophthalmology, 2000 - Elsevier To assess whether a single daily measurement using ultrasonic pachymetry gives a
representative assessment of mean central corneal thickness (CCT) in patients
with suspected glaucoma and whether diurnal changes in CCT are related to ... Cited by 42 - Related articles - BL Direct - All 7 versions
- ►duanesolution.com K Hamilton, D Pye, S Hua, F Yu, J Chung, Q … - British Medical Journal, 2007 - bjo.bmj.com Methods: 22 healthy subjects aged between 50 and 60 years were recruited.
Corneal curvature, IOP, and central corneal thickness (CCT) were measured before
and after two hours of monocular closed eye wear of a thick hydroxyethyl ... Cited by 7 - Related articles - BL Direct - All 4 versions
- ►duanesolution.com KE Hamilton, DC Pye, A Hali, C Lin, P Kam, … - Journal of glaucoma, 2007 - journals.lww.com Prior publication: The information contained in this article was published in
part at the ARVO meeting in Florida, 2005. Hamilton KE, Pye DC, Hali A, Kam P,
Lin C, Nguyen T. Corneal oedema can cause an overestimation error in ... Cited by 11 - Related articles - BL Direct - All 4 versions