Web Images Videos Maps News Shopping Gmail more »
Sign in
Scholar Home  
  Advanced Scholar Search
Scholar Preferences
Scholar Results 1 - 10 of about 101 related to Fogagnolo: Circadian variations in central corneal thickness and intraocular pressure in.... (0.12 sec) 

Circadian variations in central corneal thickness and intraocular pressure in patients with …

- nih.gov
P Fogagnolo, L Rossetti, F Mazzolani, N … - British Journal of Ophthalmology, 2006 - bjo.bmj.com
Methods: 30 patients with primary open angle glaucoma were hospitalised and
underwent circadian evaluations (at 8 pm, midnight, 4 am, 8 am, noon, and 4 pm)
of supine and sitting IOP, respectively, measured using a Perkins and a ...
Cited by 13 - Related articles - BL Direct - All 7 versions

Diurnal variation of central corneal thickness and Goldmann applanation tonometry estimates …

- duanesolution.com
KE Hamilton, DC Pye, S Aggarwala, S Evian, … - Journal of Glaucoma, 2007 - journals.lww.com
Reprints: David Cecil Pye, M. Optom, School of Optometry and Vision Science,
Level 1, North Wing, Rupert Myers Building, University of New South Wales,
Sydney NSW 2052, Australia (e-mail: d.pye@unsw.edu.au).
Cited by 17 - Related articles - BL Direct - All 4 versions

Effect of 24-hour corneal biomechanical changes on intraocular pressure measurement

- iovs.org
T Kida, JHK Liu, RN Weinreb - Investigative ophthalmology & visual science, 2006 - ARVO
RESULTS. There were consistent 24-hour variations of CCT and IOP for the group.
Nocturnal mean CCT and nocturnal mean IOP were significantly higher than the
diurnal mean CCT and diurnal mean IOP, respectively. The peak CCT occurred ...
Cited by 25 - Related articles - BL Direct - All 3 versions

A comparison of the circadian rhythm of intraocular pressure in primary chronic angle …


R Sihota, R Saxena, M Gogoi, A Sood, V … - Indian Journal of Ophthalmology, 2005 - Medknow
The pathophysiology of glaucoma is unclear. Intraocular pressure (IOP) is easily
measurable and only treatable risk factor for the prevention of progressive
glaucomatous field defects. Normal IOP varies with age, sex, time of day, ...
Cited by 7 - Related articles - Cached - BL Direct - All 5 versions

Diurnal variation curve of intraocular pressure and ocular pulse amplitude with dynamic …


HM Yun, P Fu, JS Yuan, B Zhang, XX Li - Zhonghua yi xue za zhi, 2006 - ncbi.nlm.nih.gov
OBJECTIVE: To observe the diurnal variations of intraocular pressure (IOP)
measured with dynamic contour tonometer (DCT) in primary open angle glaucoma
(POAG) patients, normal tension glaucoma (NTG) patients, and healthy ...
Cited by 2 - Related articles - BL Direct

Association of central corneal thickness and 24-hour intraocular pressure fluctuation


S Mosaed, WD Chamberlain, JHK Liu, FA … - Journal of Glaucoma, 2008 - journals.lww.com
Sameh Mosaed, MD,* Winston Douglas Chamberlain, MD, PhD,* John HK Liu, PhD,w
Felipe A. Medeiros, MD, PhD,w and Robert N. Weinreb, MDw ... Purpose: To
evaluate the association between office-hour central corneal thickness ...
Cited by 3 - Related articles - BL Direct - All 2 versions

Effects of aging on corneal biomechanical properties and their impact on 24-hour …

- nih.gov
T Kida, JHK Liu, RN Weinreb - American journal of ophthalmology, 2008 - Elsevier
Variations in 24-hour corneal hysteresis and corneal resistance factor were not
significant in the older subjects, but there were time-dependent variations in
CCT and IOP. The nocturnal CCT was thicker than the diurnal CCT, but the ...
Cited by 5 - Related articles - All 12 versions

Assessment of the diurnal variation in central corneal thickness and intraocular pressure …


S Shah, C Spedding, R Bhojwani, J Kwartz, … - Ophthalmology, 2000 - Elsevier
To assess whether a single daily measurement using ultrasonic pachymetry gives a
representative assessment of mean central corneal thickness (CCT) in patients
with suspected glaucoma and whether diurnal changes in CCT are related to ...
Cited by 42 - Related articles - BL Direct - All 7 versions

The effect of contact lens induced oedema on the accuracy of Goldmann tonometry in a …

- duanesolution.com
K Hamilton, D Pye, S Hua, F Yu, J Chung, Q … - British Medical Journal, 2007 - bjo.bmj.com
Methods: 22 healthy subjects aged between 50 and 60 years were recruited.
Corneal curvature, IOP, and central corneal thickness (CCT) were measured before
and after two hours of monocular closed eye wear of a thick hydroxyethyl ...
Cited by 7 - Related articles - BL Direct - All 4 versions

The effect of contact lens induced corneal edema on Goldmann applanation tonometry …

- duanesolution.com
KE Hamilton, DC Pye, A Hali, C Lin, P Kam, … - Journal of glaucoma, 2007 - journals.lww.com
Prior publication: The information contained in this article was published in
part at the ARVO meeting in Florida, 2005. Hamilton KE, Pye DC, Hali A, Kam P,
Lin C, Nguyen T. Corneal oedema can cause an overestimation error in ...
Cited by 11 - Related articles - BL Direct - All 4 versions


Result Page: 

1

2

3

4

5

6

7

8

9

10

Next


 


Go to Google Home - About Google - About Google Scholar

©2009 Google