- ►uminho.pt [PDF] JM Gonzalez-Meijome, J Jorge, A Queiros, P … - British Journal of Ophthalmology, 2006 - bjo.bmj.com Results: A high correlation was found between the central and peripheral IOP
readings, with the central readings being higher than the peripheral ones.
Higher IOP values for the central location were found in the younger ... Cited by 10 - Related articles - BL Direct - All 8 versions
- ►uminho.pt [PDF] A Queiros, JM González-Méijome, P …, 2006 - repositorium.sdum.uminho.pt Page 1. 1 Non-contact Tonometry Synchronized with Cardiac Rhythm and its
Relationship with Blood Pressure Queirós A1, González-Méijome ... Cited by 6 - Related articles - View as HTML - BL Direct - All 6 versions
A Queiros, JM Gonzalez-Meijome, P Fernandes, … - Ophthalmic and Physiological Optics, 2007 - duanesolution.com Results: Intraocular pressure values obtained with the ICare were 14.9 ± 2.8;
14.1 ± 2.5 and 14.5 ± 2.7 mmHg at centre, nasal and temporal corneal
locations, respectively. On average, nasal and temporal IOP readings were ... Cited by 2 - Related articles - Cached - BL Direct - All 5 versions
C Garcia-Resua, JM GONZÁLEZ-MEIJOME, … - Optometry & Vision Science, 2006 - journals.lww.com Purpose. The ICare (Tiolat Oy, Helsinki, Finland) is a new portable tonometer
that measures intraocular pressure (IOP) with a new rebound method, in which a
very light probe is used to make momentary contact with the cornea in slow ... Cited by 26 - Related articles - BL Direct - All 5 versions
LN Davies, H Bartlett, EAH Mallen, JS … - Acta Ophthalmologica Scandinavica, 2006 - interscience.wiley.com It is also possible that your web browser is not configured or not able to
display style sheets. In this case, although the visual presentation will be
degraded, the site should continue to be functional. We recommend using the ... Cited by 18 - Related articles - All 2 versions
- ►uv.es [PDF] A Cervino - British Journal of Ophthalmology, 2006 - bjo.bmj.com Goldmann applanation tonometry (GAT) has been the gold standard for intraocular
pressure (IOP) measurement since its appearance in clinical practice almost 50
years ago. 1 Despite being relatively unchallenged, the last few years have ... Cited by 2 - Related articles - BL Direct - All 5 versions
- ►duanesolution.com JMM Jorge, JM González-Méijome, A Queirós … - Journal of glaucoma, 2008 - journals.lww.com Skip Navigation Links Home > September 2008 - Volume 17 - Issue 6 > Correlations
Between Corneal Biomechanical Properties Measur... ... Disclosure: None of the
authors has a commercial or financial interest in the instruments or ... Cited by 2 - Related articles - All 6 versions
J Jorge, JM Gonzalez-Meijome, JA Diaz-Rey, … - Ophthalmic and Physiological Optics, 2003 - reichertoi.com Abstract Measuring intraocular pressure (IOP) by non-contact tonometry (NCT) has
been demonstrated to be a valid and reliable technique to be used in primary eye
care; it is easier to use, it does not transmit infectious diseases, and it ... Cited by 21 - Related articles - View as HTML - BL Direct - All 5 versions
- ►nih.gov ME Iliev, D Goldblum, K Katsoulis, C Amstutz, … - British Journal of Ophthalmology, 2006 - bjo.bmj.com Results: RT was well tolerated and safe. Intraocular pressure (IOP) ranged
between 6 mm Hg and 48 mm Hg. No different trends were found between the groups.
RT tended to give slightly higher readings: n = 101, mean difference 1.0 ... Cited by 17 - Related articles - BL Direct - All 5 versions
P Fernandes, JA Diaz-Rey, A Queiros, JM … - Ophthalmic and Physiological Optics, 2005 - interscience.wiley.com It is also possible that your web browser is not configured or not able to
display style sheets. In this case, although the visual presentation will be
degraded, the site should continue to be functional. We recommend using the ... Cited by 41 - Related articles - BL Direct - All 6 versions