- ►nih.gov Y Wang, L Xu, L Zhang, H Yang, Y Ma, JB … - British Journal of Ophthalmology, 2006 - bjo.bmj.com Results: Optic disc photographs were available for 4027 (90.7%) subjects. Mean
optic disc area measured 2.65 (0.57) mm 2 (range 1.03 mm 2 –7.75 mm 2 ). Optic
disc area was significantly (p<0.001) correlated with myopic refractive ... Cited by 32 - Related articles - BL Direct - All 6 versions
Y Wang, L Xu, JB Jonas - American journal of ophthalmology, 2006 - Elsevier Of the 4439 people who were examined, 4350 subjects (98.0%; 8617 eyes) provided
measurement data by frequency doubling perimetry. In subjects aged 40 to 49
years, the most frequent cause for VFL was degenerative myopia followed by ... Cited by 15 - Related articles - All 19 versions
- ►nih.gov - Free from Publisher L Xu, J Li, T Cui, A Hu, Y Zheng, Y Li, B Sun, … - British Journal of Ophthalmology, 2005 - bjo.bmj.com Results: Mean uncorrected visual acuity measured 0.72 (0.32) (median, 0.80), and
mean best corrected visual acuity measured 0.91 (0.21) (median, 1.0). In a
multiple regression analysis, best corrected visual acuity was ... Cited by 23 - Related articles - BL Direct - All 8 versions
L Xu, J Li, Y Zheng, T Cui, J Zhu, K Ma, H … - American journal of ophthalmology, 2005 - Elsevier Mean IOP was 16.11 ± 3.39 mm Hg (median, 16 mm Hg; range, 7–60 mm Hg). In the
rural group and the urban population group, respectively, IOP was significantly
(P = .016 and P = .029, respectively) lower in the high-age group (≥75 ... Cited by 17 - Related articles - All 15 versions
PR Healey, P Mitchell - American journal of ophthalmology, 1999 - Elsevier PURPOSE: To compare optic disk size in eyes of subjects classified as normal
with the eyes of subjects with open-angle glaucoma, ocular hypertension, or
pseudoexfoliation syndrome in an older population-based sample. Cited by 27 - Related articles - BL Direct - All 10 versions
JB Jonas - American journal of ophthalmology, 2005 - Elsevier To evaluate for which range of refractive error the optic disk size depends on,
or is independent of, the refractive error. ... The study included 1999 eyes of
1011 subjects with a mean refractive error of −0.97 ± 2.72 diopters ... Cited by 23 - Related articles - All 13 versions
S Cheung, P Cho, W Douthwaite - Ophthalmic and Physiological Optics, 2000 - interscience.wiley.com Corneal asphericity (the p-value, p) and apical corneal radius (r 0 ) were
calculated for 63 Hong Kong-Chinese (39 male and 24 female), using the
Topographic Modeling System (TMS-1). The values of p and r 0 in, and ... Cited by 25 - Related articles - BL Direct - All 4 versions
RS Ramrattan, RCW Wolfs, JB Jonas, A … - Ophthalmology, 1999 - Elsevier A total of 5114 subjects 55 years of age or older participated in this study,
representing 76% of a population-based sample of 6777 ophthalmologically
examined white patients from a geographically well-defined suburb in ... Cited by 72 - Related articles - BL Direct - All 5 versions