Scholar Results 1 - 10 of about 101 related to Iliev: Comparison of rebound tonometry with Goldmann applanation tonometry and correlation.... (0.09 sec) 

Comparison of rebound tonometry with Goldmann applanation tonometry and correlation with …

- nih.gov
ME Iliev, D Goldblum, K Katsoulis, C Amstutz, … - British Journal of Ophthalmology, 2006 - bjo.bmj.com
Results: RT was well tolerated and safe. Intraocular pressure (IOP) ranged
between 6 mm Hg and 48 mm Hg. No different trends were found between the groups.
RT tended to give slightly higher readings: n = 101, mean difference 1.0 ...
Cited by 17 - Related articles - BL Direct - All 5 versions

Clinical evaluation of rebound tonometer


LN Davies, H Bartlett, EAH Mallen, JS … - Acta Ophthalmologica Scandinavica, 2006 - interscience.wiley.com
It is also possible that your web browser is not configured or not able to
display style sheets. In this case, although the visual presentation will be
degraded, the site should continue to be functional. We recommend using the ...
Cited by 18 - Related articles - All 2 versions

Comparison of ICare tonometer with Goldmann applanation tonometer in glaucoma patients

- bon.de [PDF] 
P Brusini, ML Salvetat, M Zeppieri, C Tosoni, L … - Journal of Glaucoma, 2006 - journals.lww.com
Glaucoma is a major cause of blindness in the Western countries.1 It is well
known that the major risk factors in the progression of glaucoma include
increased ... Copyright r 2006 by Lippincott Williams & Wilkins
Cited by 23 - Related articles - All 3 versions

Agreement of rebound tonometer in measuring intraocular pressure with three types of …


M Nakamura, U Darhad, Y Tatsumi, M Fujioka … - American journal of ophthalmology, 2006 - Elsevier
To evaluate the agreement of iCare rebound tonometer in measuring intraocular
pressure (IOP) with Goldmann applanation tonometer (GAT), Tonopen XL, and
noncontact tonometer, and the influence of the central corneal thickness ...
Cited by 17 - Related articles - All 16 versions

Comparison of the ICare® rebound tonometer with the Goldmann applanation tonometer by …


LM Abraham, NCR Epasinghe, D Selva, R … - Eye, 2006 - nature.com
Two tonometrists, experienced with both Goldmann applanation tonometry (GAT) and
ICare® Tonometry (ICT) measured intraocular pressure (IOP), in a masked
fashion, in 100 patients. In another series of 58 patients, ICT was ...
Cited by 7 - Related articles - BL Direct - All 3 versions

Accuracy of the new ICare rebound tonometer vs. other portable tonometers in healthy eyes


C Garcia-Resua, JM GONZÁLEZ-MEIJOME, … - Optometry & Vision Science, 2006 - journals.lww.com
Purpose. The ICare (Tiolat Oy, Helsinki, Finland) is a new portable tonometer
that measures intraocular pressure (IOP) with a new rebound method, in which a
very light probe is used to make momentary contact with the cornea in slow ...
Cited by 26 - Related articles - BL Direct - All 5 versions

Rebound tonometry: new opportunities and limitations of non-invasive determination of …

- uv.es [PDF] 
A Cervino - British Journal of Ophthalmology, 2006 - bjo.bmj.com
Goldmann applanation tonometry (GAT) has been the gold standard for intraocular
pressure (IOP) measurement since its appearance in clinical practice almost 50
years ago. 1 Despite being relatively unchallenged, the last few years have ...
Cited by 2 - Related articles - BL Direct - All 5 versions

Age differences in central and peripheral intraocular pressure using a rebound tonometer

- uminho.pt [PDF] 
JM Gonzalez-Meijome, J Jorge, A Queiros, P … - British Journal of Ophthalmology, 2006 - bjo.bmj.com
Results: A high correlation was found between the central and peripheral IOP
readings, with the central readings being higher than the peripheral ones.
Higher IOP values for the central location were found in the younger ...
Cited by 10 - Related articles - BL Direct - All 8 versions

Clinical comparison of the Icare tonometer and Goldmann applanation tonometry


N Pakrou, T Gray, R Mills, J Landers, J Craig - Journal of Glaucoma, 2008 - journals.lww.com
Nima Pakrou, MBBS, Tim Gray, MBBS, Richard Mills, FRANZCO, John Landers, MBBS,
MPH, and Jamie Craig, MBBS, PhD, DPhil, FRANZCO ... Purpose: To compare a new
method of intraocular pressure (IOP) measurement, using the Icare ...
Cited by 4 - Related articles - BL Direct - All 2 versions

Three portable tonometers, the TGDc-01, the ICARE and the Tonopen XL, compared with …


LH van der Jagt, NM Jansonius - Ophthalmic and Physiological Optics, 2005 - interscience.wiley.com
Three portable tonometers, the TGDc-01, the ICARE and the Tonopen XL, were
compared with each other and to Goldmann applanation tonometry in a large group
of healthy subjects and patients with ocular hypertension or glaucoma (n = ...
Cited by 32 - Related articles - BL Direct - All 4 versions