Web Images Videos Maps News Shopping Gmail more »
Sign in
Scholar Home  
  Advanced Scholar Search
Scholar Preferences
Scholar Results 1 - 10 of about 101 related to Spry: Performance of the 24-2-5 frequency doubling technology screening test: a prospective.... (0.18 sec) 

Performance of the 24-2-5 frequency doubling technology screening test: a prospective case …


PGD Spry, HM Hussin, JM Sparrow - British Journal of Ophthalmology, 2007 - bjo.bmj.com
Results: Of 63 referred eligible individuals, 53 (84%) were recruited.
Sensitivity and specificity for the N-30-5 screening test was 78 and 85%
respectively, compared with 83% and 75% for the 24-2-5 with areas under a ...
Cited by 1 - Related articles - BL Direct - All 4 versions

Correcting lens system for perimetry


DB Henson, RA Earlam - Ophthalmic and Physiological Optics, 1995 - interscience.wiley.com
A lens system to correct for both refractive error and perimeter test distance
is frequently needed for accurate perimetry. Patients often lack appropriate
near vision corrections and full aperture trial case lenses, when they are ...
Cited by 4 - Related articles - BL Direct - All 3 versions

[CITATION] A primer for frequency doubling technology (FDT) perimetry using the Humphrey Matrix


CA Johnson, P Gunvant, M Fingeret… - Welch-Allyn, Zeiss, 2004
Cited by 4 - Related articles

Evaluation of the High-Specificity Screening Program (C-20-1) of the Frequency Doubling …


RV North, JM Wild, E Hunter, AL Jones, JE … - Investigative Ophtalmology and Visual Science, 2002 - ARVO
Commercial Relationships: RV North, None; JM Wild, Humphrey Systems, Inc. R; E.
Hunter, None; AL Jones, None; JE Morgan, None. ... Purpose: The efficacy of the
FDT Program C-20-1, which has high specificity, has received relatively ...
Cited by 4 - Related articles - BL Direct - All 5 versions

Detecting glaucoma with frequency-doubling technology perimetry: a comparison between …


P Fogagnolo, F Mazzolani, L Rossetti, N … - Journal of Glaucoma, 2005 - journals.lww.com
Skip Navigation Links Home > December 2005 - Volume 14 - Issue 6 > Detecting
Glaucoma with Frequency-Doubling Technology Perime... ... From Eye Clinic,
Department of Medicine, Surgery, and Odontoiatry, San Paolo Hospital, ...
Cited by 5 - Related articles - BL Direct - All 2 versions

Glaukomreihenuntersuchung mittels Heidelberg-Retina-Tomograph II Glaucoma-Screening …


P Kóthy, P Vargha, G Holló - Klin Monatsbl Augenheilkd, 2003 - thieme-connect.com
Hintergrund: Das Ziel der Studie war, den Nutzwert des
Heidelberg-Retina-Tomograph II (HRT II) während einer Glaukomreihenuntersuchung
zu beurteilen. Patienten und Methoden: HRT-II-Untersuchungen wurden an 53 ...
Cited by 5 - Related articles - BL Direct - All 3 versions

Frequency-doubling technology: searching for the optimum diagnostic criteria for glaucoma


A Ferreras, JM Larrosa, V Polo, AB Pajarin, … - Acta Ophthalmologica Scandinavica, 2007 - interscience.wiley.com
It is also possible that your web browser is not configured or not able to
display style sheets. In this case, although the visual presentation will be
degraded, the site should continue to be functional. We recommend using the ...
Cited by 5 - Related articles - BL Direct - All 3 versions

Accuracy of combined GDx-VCC and matrix FDT in a glaucoma screening trial


M Tóth, P Kóthy, P Vargha, G Holló - Journal of Glaucoma, 2007 - journals.lww.com
Skip Navigation Links Home > August 2007 - Volume 16 - Issue 5 > Accuracy of
Combined GDx-VCC and Matrix FDT in a Glaucoma Sc... ... Reprints: Gábor
Holló, MD, PhD, DSc, 1083, Budapest, Tömö u. 25-29, Hungary (e-mail: ...
Cited by 6 - Related articles - BL Direct - All 4 versions

Quantifying effects of retinal illuminance on frequency doubling perimetry

- iovs.org
WH Swanson, MW Dul, SE Fischer - Investigative ophthalmology & visual science, 2005 - ARVO
METHODS. A Zeiss-Humphrey/Welch Allyn FDT perimeter was used with the threshold
N-30 strategy. Study 1, quantifying adaptation: 11 eyes of 11 subjects (24–46
years old) were tested with natural pupils, and then retested after stable ...
Cited by 6 - Related articles - All 3 versions

Clinical evaluation of frequency doubling technology perimetry using the Humphrey Matrix …

- nih.gov - Free from Publisher
PGD Spry, HM Hussin, JM Sparrow - British Journal of Ophthalmology, 2005 - bjo.bmj.com
Results: 48 of 62 eligible referred individuals were recruited. Glaucoma
prevalence was 31%. Median test duration per eye was 5 minutes 16 seconds for
FDT and 5 minutes 9 seconds for SAP. There was no significant difference (p ...
Cited by 26 - Related articles - BL Direct - All 9 versions


Result Page: 

1

2

3

4

5

6

7

8

9

10

Next


 


Go to Google Home - About Google - About Google Scholar

©2009 Google