Scholar Results 1 - 10 of about 101 related to Li: Repeatability and reproducibility of anterior chamber angle measurement with anterior.... (0.10 sec) 

Repeatability and reproducibility of anterior chamber angle measurement with …


H Li, CKS Leung, CYL Cheung, L Wong, CP … - British Journal of …, 2007 - bjo.bmj.com
Methods: Twenty-five normal subjects were invited for anterior chamber angle imaging with an
anterior segment optical coherence tomography (OCT) on one randomly selected eye in three
separate visits within a week. Each eye was imaged three times under room light (light ...
Cited by 16 - Related articles - BL Direct - All 3 versions

Repeatability and Reproducibility of Anterior


SOC Tomography - bjo.bmj.com
Page 1. doi: 10.1136/bjo.2007.118901 published online May 2, 2007 Br J Ophthalmol
Haitao Li, Christopher Kai Shun Leung, Carol Yim Lui Cheung, et al. Segment Optical
Coherence Tomography Chamber Angle Measurement ...
Related articles

Reproducibility of anterior chamber angle measurements obtained with anterior …

- iovs.org [PDF] 
S Radhakrishnan, J See, SD Smith, WP Nolan, Z Ce, … - … ophthalmology & visual …, 2007 - ARVO
PURPOSE. To evaluate the reproducibility of anterior chamber (AC) angle measurements obtained
using anterior segment optical coherence tomography (AS-OCT). METHODS. Patients with suspected
glaucoma and those with glaucoma, ocular hypertension, or anatomically narrow angles ...
Cited by 15 - Related articles - BL Direct - All 4 versions

Anterior chamber angle measurement with optical coherence tomography: …


M Müller, G Dahmen, E Pörksen, G Geerling, H … - Journal of Cataract & …, 2006 - Elsevier
The mean anterior chamber angle measurement was 35.9 degrees ± 5.7 (SD) for observer A
and 36.2 ± 5.7 degrees for observer B. The ICC was 0.94 and 0.91, respectively. The mean opening
width was 315 ± 62 μm for observer A and 317 ± 60 μm for observer B. The ICC was 0.97 ...
Cited by 23 - Related articles - All 9 versions

Comparison of anterior segment optical coherence tomography and ultrasound …

- sightway.com [PDF] 
T Dada, R Sihota, R Gadia, A Aggarwal, S Mandal, … - Journal of Cataract & …, 2007 - Elsevier
There was an excellent correlation between AS-OCT and UBM measurements for the nasal angle
(r = 0.84; P<.0001), temporal angle (r = 0.86; P<.0001), ACD (r = 0.97; P<.0001), and CCT (r
= 0.91; P<.0001). There was no significant difference (paired t test) between the mean ...
Cited by 33 - Related articles - All 4 versions

[CITATION] Slit-lamp-adapted optical coherence tomography for assessment of an …


TS Prata, CG De Moraes, PM Palmiero, C Tello, J … - Acta …, 2009 - ncbi.nlm.nih.gov
1: Acta Ophthalmol. 2009 Feb 6. [Epub ahead of print]. Slit-lamp-adapted optical
coherence tomography for assessment of an overhanging filtering bleb. Prata TS, De
Moraes CG, Palmiero PM, Tello C, Liebmann J, Ritch R. Einhorn ...
Cited by 1 - Related articles - All 2 versions

Anterior segment imaging for glaucoma: OCT or UBM?


H Ishikawa - British Medical Journal, 2007 - bjo.bmj.com
Ultrasound biomicroscopy (UBM) had played the dominant role in objective imaging of the anterior
chamber angle until anterior segment optical coherence tomography (ASOCT) was introduced
in 2003. Although ASOCT provides a higher axial resolution (18 µm in commercial ...
Cited by 2 - Related articles - BL Direct - All 3 versions

Anterior segment optical coherence tomography for imaging the anterior chamber …

- nih.gov
F Memarzadeh, Y Li, V Chopra, R Varma, BA … - American journal of …, 2007 - Elsevier
Ten eyes of 10 patients with narrow angles were enrolled in the study. Angles were assessed
by gonioscopy and anterior segment OCT pre- and post-LPI. The angle opening distance at 500
μm, angle recess area at 500 μm and 750 μm, and trabecular-iris space area at 500 μm ...
Cited by 11 - Related articles - All 13 versions

Optical coherence tomography in anterior segment imaging


M Kalev-Landoy, AC Day, MF Cordeiro, … - Acta Ophthalmologica …, 2007 - pubmedcentral.nih.gov
In a prospective observational study, the anterior segments of 26 eyes of 26 patients were imaged
using the Zeiss Stratus OCT, model 3000. Imaging of the anterior segment was achieved by adjusting
the focusing control on the Stratus OCT. A total of 16 patients had abnormal angle ...
Cited by 12 - Related articles - BL Direct - All 7 versions

[CITATION] Detection of ciliary body detachment with anterior segment optical coherence …


A Burés-Jelstrup, R Navarro, C Mateo, A Adan, B … - Acta …, 2008 - ncbi.nlm.nih.gov
1: Acta Ophthalmol. 2008 Nov;86(7):810-1. Epub 2008 Jan 24. Detection of ciliary body
detachment with anterior segment optical coherence tomography. Burés-Jelstrup A, Navarro
R, Mateo C, Adan A, Corcóstegui B. Instituto de Microcirugia Ocular, Barcelona, Spain. ...
Cited by 3 - Related articles - All 2 versions