Web Images Videos Maps News Shopping Gmail more »
Sign in
Scholar Home  
  Advanced Scholar Search
Scholar Preferences
Scholar Results 1 - 10 of about 101 related to Stellingwerf: Two-field photography can identify patients with vision-threatening diabetic.... (0.09 sec) 

Two-field photography can identify patients with vision-threatening diabetic …

- diabetesjournals.org
C Stellingwerf, PLLJ Hardus, JMM Hooymans - Diabetes Care, 2001 - Am Diabetes Assoc
RESEARCH DESIGN AND METHODS—Type 1 and 2 diabetic patients without a known history
of more than minimal retinopathy (n = 469) had a routine examination by an
ophthalmologist, including visual acuity measurement, indirect retinoscopy, and ...
Cited by 32 - Related articles - BL Direct - All 5 versions

The effectiveness of screening for diabetic retinopathy by digital imaging …


PH Scanlon, R Malhotra, G Thomas, C Foy, JN … - Diabetic …, 2003 - interscience.wiley.com
It is also possible that your web browser is not configured or not able to display style sheets.
In this case, although the visual presentation will be degraded, the site should continue to be
functional. We recommend using the latest version of Microsoft or Mozilla web browser to ...
Cited by 47 - Related articles - BL Direct - All 4 versions

Validez de la cámara no midriática en el cribado de la retinopatía diabética y …


M Baeza Díaz, V Gil Guillén, D Orozco … - Archivos de la …, 2004 - europa.sim.ucm.es
Objetivo: Analizar la validez de la cámara no midriática para detectar retinopatía diabética y
los grados de severidad susceptibles de derivación al oftalmólogo. Analizar los indicadores
de gravedad de la retinopatía diabética que puedan ayudar a aumentar la sensibilidad ...
Cited by 13 - Related articles - Cached

Is One 60° Fundus Photograph Sufficient for Screening of Proliferative Diabetic …


F Møller, M Hansen, AK Sjølie - Diabetes care, 2001 - Am Diabetes Assoc
RESEARCH DESIGN AND METHODS—A total of 44 eyes in 23 patients with moderate/severe
nonproliferative diabetic retinopathy were included. Evaluation of each eye was based on one
60° fundus photograph. Eyes were re-examined using seven field 30° stereo fundus ...
Cited by 14 - Related articles - BL Direct - All 5 versions

Is screening with digital imaging using one retinal view adequate?


HM Herbert, K Jordan, DW Flanagan - Eye, 2003 - nature.com
Results A total of 145 patients (288 eyes) were identified for screening. Of these, 26% of eyes
had diabetic retinopathy, and eight eyes (3%) had sight-threatening diabetic retinopathy requiring
treatment. The sensitivity for detection of any diabetic retinopathy was 38% and the ...
Cited by 21 - Related articles - BL Direct - All 3 versions

Concordancia en la exploración de fondo de ojo en el cribaje de la retinopatía …


M Baeza Díaz, V Pedrera Carbonell, R … - Archivos de la …, 1999 - europa.sim.ucm.es
Concordancia en la exploración de fondo de ojo en el cribaje de la retinopatía
diabética entre el Médico de Familia y el Oftalmólogo. M Baeza Díaz, V Pedrera
Carbonell, R Reigadas López, D Orozco Beltrán, F Soler Ferrández ...
Cited by 5 - Related articles - Cached - BL Direct

Comparison of two reference standards in validating two field mydriatic digital …


PH Scanlon, R Malhotra, RH Greenwood, SJ … - British Journal of …, 2003 - bjo.bmj.com
Results: In comparison with seven field stereophotography, the ophthalmologist's examination
gave a sensitivity of 87.4% (confidence interval 83.5 to 91.5), a specificity of 94.9% (91.5 to
98.3), and a kappa statistic of 0.80. Two field mydriatic digital photography gave a ...
Cited by 40 - Related articles - BL Direct - All 9 versions

[CITATION] Estudio de la eficiencia de una cámara de retina no-midriática en el diagnóstico de …


MC Hernáez-Ortega, E Soto-Pedre, JA Vázquez, … - Revista Clinica …, 1998 - cat.inist.fr
ESTUDIO DE LA EFICIENCIA DE UNA CAMARA DE RETINA NO-MIDRIATICA EN EL
DIAGNOSTICO DE RETINOPATIA DIABETICA. MC HERNAEZ-ORTEGA, E SOTO-PEDRE, JA
VAZQUEZ, MA GUTIERREZ, J ASUA Revista Clinica Espanola 198:44, 194-199, Doyma, 1998.
Cited by 9 - Related articles

Accuracy of screening for diabetic retinopathy by family physicians

- nih.gov
JM Gill, DM Cole, HM Lebowitz, JJ … - The Annals of Family …, 2004 - Annals Family Med
METHODS Eleven family physicians assessed 28 standardized patients with diabetes mellitus
using the PanOptic ophthalmoscope. Their assessments of whether the patients required referral
to an ophthalmologist were compared with the reference standard of retinal diagrams.
Cited by 13 - Related articles - BL Direct - All 20 versions

The value of digital imaging in diabetic retinopathy.


PF Sharp, J Olson, F Strachan, J Hipwell, A … - Health technology …, 2003 - ncbi.nlm.nih.gov
OBJECTIVES: To assess the performance of digital imaging, compared with other
modalities, in screening for and monitoring the development of diabetic retinopathy.
DESIGN: All imaging was acquired at a hospital assessment clinic. Subsequently, study ...
Cited by 21 - Related articles - All 2 versions


Result Page: 

1

2

3

4

5

6

7

8

9

10

Next


 


Go to Google Home - About Google - About Google Scholar

©2009 Google