Web Images Videos Maps News Shopping Gmail more »
Sign in
Scholar Home  
  Advanced Scholar Search
Scholar Preferences
Scholar Results 1 - 10 of about 101 related to Dassau: Detection of a Meal Using Continuous Glucose Monitoring. (0.10 sec) 

Detection of a Meal Using Continuous Glucose Monitoring

- Free from Publisher
E Dassau, BW Bequette, BA Buckingham, FJ … - Diabetes Care, 2008 - Am Diabetes Assoc
RESEARCH DESIGN AND METHODS—We developed our MDA on a dataset of 26 meal
events using records from 19 children aged 1–6 years who used the MiniMed CGMS
Gold. We then applied this algorithm to CGM records from a DirecNet pilot ...
Cited by 12 - Related articles - BL Direct - All 5 versions

[PDF] A closed-loop artificial pancreas based on MPC: human-friendly identification and automatic …


H Lee, BW Bequette - Insulin [U/hr] - nt.ntnu.no
Abstract: Type 1 diabetes is characterized by a lack of insulin production from
the pancreas, causing high blood glucose concentrations and requiring external
insulin infusion to regulate blood glucose. A novel procedure of “human- ...
Cited by 2 - Related articles - View as HTML

[PDF] GIM, simulation software of meal glucose-insulin model


C Dalla Man, DM Raimondo, RA Rizza, C … - J Diabetes Sci Technol, 2007 - journalofdst.org
Author Affiliations: 1Department of Information Engineering, University of
Padova, I-35131 Padova, Italy; 2Dipartimento di Informatica e Sistemistica,
University of Pavia, 27100 Pavia, Italy; and 3Mayo Clinic, Division of ...
Cited by 12 - Related articles - View as HTML - All 2 versions

I. Glucose control strategies for treating type 1 diabetes mellitus

- cmu.edu [PDF] 
F Doyle, L Jovanovič, D Seborg - Journal of Process Control, 2007 - Elsevier
Type 1 diabetes mellitus is a disease characterized by complete pancreatic
β-cell insufficiency. The only treatment is with subcutaneous or intravenous
insulin injections, traditionally administered in an open-loop manner. ...
Cited by 4 - Related articles - All 2 versions

Pharmacodynamics and stability of subcutaneously infused glucagon in a type 1 diabetic …


FH El-Khatib, J Jiang, RG Gerrity, ER … - Diabetes Technology & Therapeutics, 2007 - liebertonline.com
FIRAS H. EL-KHATIB, Ph.D., 1 JOHN JIANG, BS, 1 ROSS G. GERRITY, Ph.D., 2 ...
Background: The objective of this study was to determine the in vivo
pharmacodynamics of glucagon and to test its glycemic effect over days by ...
Cited by 5 - Related articles - BL Direct - All 3 versions

A plant-friendly multivariable system identification framework based on identification test …


H Lee, 2006 - gradworks.umi.com
Abstract: Historically, model development for advanced process control
applications has been a major consideration, demanding significant time and
effort. The increased use of advanced control systems in industry creates a ...
Cited by 7 - Related articles - Cached - All 2 versions

The future of continuous glucose monitoring: closed loop


R Hovorka - Current Diabetes Reviews, 2008 - ingentaconnect.com
Abstract: Improvements in accuracy of real-time continuous glucose monitoring
facilitate the development of closed-loop systems consisting of a continuous
glucose monitor, a control algorithm, and an insulin pump. Closed- loop ...
Cited by 7 - Related articles - All 2 versions

Preventing hypoglycemia using predictive alarm algorithms and insulin pump suspension


B Buckingham, E Cobry, P Clinton, V Gage, … - Diabetes Technology & Therapeutics, 2009 - liebertonline.com
Page 1. DIABETES TECHNOLOGY & THERAPEUTICS Volume 11, Number 2, 2009 © Mary
Ann Liebert, Inc. DOI: 10.1089/dia.2008.0032 Preventing ...
Cited by 7 - Related articles - All 3 versions

The Medtronic Minimed Gold continuous glucose monitoring system: an effective means to …


LM Gandrud, D Xing, C Kollman, JM Block, … - Diabetes technology & therapeutics, 2007 - liebertonline.com
Page 1. DIABETES TECHNOLOGY & THERAPEUTICS Volume 9, Number 4, 2007 © Mary Ann Liebert,
Inc. DOI: 10.1089/dia.2007.0026 The Medtronic MiniMed Gold Continuous ...
Cited by 7 - Related articles - BL Direct - All 4 versions

A critical assessment of algorithms and challenges in the development of a closed-loop …


BW Bequette - Diabetes technology & therapeutics, 2005 - liebertonline.com
The development of an artificial pancreas is placed in the context of the
history of the field of feedback control systems, beginning with the water clock
of ancient Greece, and including a dis- cussion of current efforts in the ...
Cited by 67 - Related articles - All 2 versions


Result Page: 

1

2

3

4

5

6

7

8

9

10

Next


 


Go to Google Home - About Google - About Google Scholar