Scholar Results 1 - 10 of about 101 related to Weinzimer: Fully automated closed-loop insulin delivery versus semiautomated hybrid control.... (0.16 sec) 

Fully automated closed-loop insulin delivery versus semiautomated hybrid control in pediatric …


SA Weinzimer, GM Steil, KL Swan, J Dziura, … - Diabetes Care, 2008 - Am Diabetes Assoc
OBJECTIVE—The most promising β-cell replacement therapy for children with
type 1 diabetes is a closed-loop artificial pancreas incorporating continuous
glucose sensors and insulin pumps. The Medtronic MiniMed external ...
Cited by 30 - Related articles - BL Direct - All 5 versions

Preventing hypoglycemia using predictive alarm algorithms and insulin pump suspension


B Buckingham, E Cobry, P Clinton, V Gage, … - Diabetes Technology & Therapeutics, 2009 - liebertonline.com
Page 1. DIABETES TECHNOLOGY & THERAPEUTICS Volume 11, Number 2, 2009 © Mary
Ann Liebert, Inc. DOI: 10.1089/dia.2008.0032 Preventing ...
Cited by 7 - Related articles - All 3 versions

Feasibility of automating insulin delivery for the treatment of type 1 diabetes


GM Steil, K Rebrin, C Darwin, F Hariri, MF … - Diabetes, 2006 - Am Diabetes Assoc
An automated closed-loop insulin delivery system based on subcutaneous glucose
sensing and subcutaneous insulin delivery was evaluated in 10 subjects with type
1 diabetes (2 men, 8 women, mean [±SD] age 43.4 ± 11.4 years, duration of ...
Cited by 41 - Related articles - BL Direct - All 5 versions

Response to nocturnal alarms using a real-time glucose sensor

- nih.gov
B Buckingham, J Block, J Burdick, A Kalajian … - Diabetes technology & therapeutics, 2005 - liebertonline.com
Page 1. 440 DIABETES TECHNOLOGY & THERAPEUTICS Volume 7, Number 3, 2005 © Mary Ann
Liebert, Inc. Response to Nocturnal Alarms Using a Real-Time Glucose Sensor ...
Cited by 17 - Related articles - All 6 versions

Pharmacodynamics and stability of subcutaneously infused glucagon in a type 1 diabetic …


FH El-Khatib, J Jiang, RG Gerrity, ER … - Diabetes Technology & Therapeutics, 2007 - liebertonline.com
FIRAS H. EL-KHATIB, Ph.D., 1 JOHN JIANG, BS, 1 ROSS G. GERRITY, Ph.D., 2 ...
Background: The objective of this study was to determine the in vivo
pharmacodynamics of glucagon and to test its glycemic effect over days by ...
Cited by 5 - Related articles - BL Direct - All 3 versions

Sensor-augmented pump therapy in type 1 diabetes


SA Weinzimer, WV Tamborlane - Current Opinion in Endocrinology, Diabetes and …, 2008 - journals.lww.com
Purpose of review: Recent developments in technology have ushered in a new era
of managing type 1 diabetes. Continuous glucose monitoring is rapidly becoming
an accepted adjunct to traditional self-monitoring of plasma glucose, and ...
Cited by 10 - Related articles - BL Direct - All 2 versions

The accuracy of the FreeStyle Navigator continuous glucose monitoring system in children …

- diabetesjournals.org
DM Wilson, RW Beck, WV Tamborlane, MJ … - Diabetes Care, 2007 - Am Diabetes Assoc
RESEARCH DESIGN AND METHODS—In 30 children with type 1 diabetes (mean age 11.2
± 4.1 years), the Navigator glucose values were compared with reference serum
glucose values of blood samples obtained in an inpatient clinical research ...
Cited by 42 - Related articles - BL Direct - All 6 versions

Modeling β-Cell Insulin Secretion-Implications for Closed-Loop Glucose Homeostasis


GM Steil, K Rebrin, R Janowski, C Darwin, … - Diabetes Technology & Therapeutics, 2003 - liebertonline.com
Page 1. DIABETES TECHNOLOGY & THERAPEUTICS Volume 5, Number 6, 2003 © Mary Ann
Liebert, Inc. Modeling b-Cell Insulin Secretion—Implications for ...
Cited by 31 - Related articles - BL Direct - All 2 versions

Detection of a Meal Using Continuous Glucose Monitoring

- Free from Publisher
E Dassau, BW Bequette, BA Buckingham, FJ … - Diabetes Care, 2008 - Am Diabetes Assoc
RESEARCH DESIGN AND METHODS—We developed our MDA on a dataset of 26 meal
events using records from 19 children aged 1–6 years who used the MiniMed CGMS
Gold. We then applied this algorithm to CGM records from a DirecNet pilot ...
Cited by 12 - Related articles - BL Direct - All 5 versions

In silico preclinical trials: a proof of concept in closed-loop control of type 1 diabetes


BP Kovatchev, M Breton, C Dalla Man, C … - Journal of diabetes science and technology (Online), 2009 - pubmedcentral.nih.gov
Arguably, a minimally invasive system using subcutaneous (sc) continuous glucose
monitoring (CGM) and sc insulin delivery via insulin pump would be a most
feasible step to closed-loop control in type 1 diabetes mellitus (T1DM). ...
Cited by 3 - Related articles - All 3 versions