B Kovatchev, S Anderson, L Heinemann, W … - Diabetes Care, 2008 - Am Diabetes Assoc In their comments on our assessment of the accuracy of four continuous glucose
monitoring (CGM) sensors, Brauker and Matsubara (1) correctly point out that our
presented studies employed hyperinsulinemic-euglycemic and hypoglycemic ... Cited by 19 - Related articles - BL Direct - All 6 versions
PG Fabietti, V Canonico, M Orsini-Federici, E … - Diabetes Technology & Therapeutics, 2007 - liebertonline.com Background: The development of an artificial pancreas requires an accurate
representation of diabetes pathophysiology to create effective and safe control
systems for automatic insulin in- fusion regulation. The aim of the present ... Cited by 8 - Related articles - BL Direct - All 3 versions
[CITATION] Diabetes Research in Children Network (DirecNet) Study Group. Use of the DirecNet Applied …
J Brauker, B Matsubara - Diabetes Care, 2008 - Am Diabetes Assoc This study did not evaluate CGM systems per their intended use under normal
therapeutic conditions. Instead, glucose was manipulated using a glucose clamp
of intravenous glucose and insulin infusion. The hyperinsulinemic clamp ... Cited by 2 - Related articles - All 3 versions
BP Kovatchev, C King, M Breton, S Anderson, … - Engineering in Medicine and Biology Society, 2006. …, 2006 - ieeexplore.ieee.org Cited by 3 - Related articles - All 3 versions
BP Kovatchev, M Breton, C Dalla Man, C … - Journal of diabetes science and technology (Online), 2009 - pubmedcentral.nih.gov Arguably, a minimally invasive system using subcutaneous (sc) continuous glucose
monitoring (CGM) and sc insulin delivery via insulin pump would be a most
feasible step to closed-loop control in type 1 diabetes mellitus (T1DM). ... Cited by 3 - Related articles - All 3 versions
- ►diabetesjournals.org DM Wilson, RW Beck, WV Tamborlane, MJ … - Diabetes Care, 2007 - Am Diabetes Assoc RESEARCH DESIGN AND METHODS—In 30 children with type 1 diabetes (mean age 11.2
± 4.1 years), the Navigator glucose values were compared with reference serum
glucose values of blood samples obtained in an inpatient clinical research ... Cited by 42 - Related articles - BL Direct - All 6 versions
SA Weinzimer, GM Steil, KL Swan, J Dziura, … - Diabetes Care, 2008 - Am Diabetes Assoc OBJECTIVE—The most promising β-cell replacement therapy for children with
type 1 diabetes is a closed-loop artificial pancreas incorporating continuous
glucose sensors and insulin pumps. The Medtronic MiniMed external ... Cited by 30 - Related articles - BL Direct - All 5 versions
[CITATION] Pharmacological Management of Type 2 Diabetes