Web Images Videos Maps News Shopping Gmail more »
Sign in
Scholar Home  
  Advanced Scholar Search
Scholar Preferences
Scholar Results 1 - 10 of about 101 related to Fromy: Early decrease of skin blood flow in response to locally applied pressure in diabetic.... (0.17 sec) 

Early decrease of skin blood flow in response to locally applied pressure in …


B Fromy, P Abraham, C Bouvet, B Bouhanick, P … - Diabetes, 2002 - Am Diabetes Assoc
Pressure ulcers are common debilitating complications of diabetes that are caused by tissue
ischemia. Skin blood flow in response to locally applied pressure might be impaired in diabetic
patients because of the combined effects of a typically low skin temperature and ...
Cited by 28 - Related articles - BL Direct - All 4 versions

Mechanisms of the cutaneous vasodilator response to local external pressure …


B Fromy, S Merzeau, P Abraham, JL … - British journal of …, 2000 - pubmedcentral.nih.gov
Cutaneous blood flow was measured by laser Doppler flowmetry during 11.1 Pa s −1 increases
in local applied pressure in anaesthetized rats. The involvement of capsaicin-sensitive fibres
in PIV was tested in rats treated neonatally with capsaicin. To antagonize CGRP, ...
Cited by 33 - Related articles - BL Direct - All 5 versions

Non-nociceptive capsaicin-sensitive nerve terminal stimulation allows for an …


B Fromy, P Abraham, JL Saumet - Brain research, 1998 - Elsevier
The human skin acts like a natural barrier to external aggressions and the regulation of cutaneous
blood flow is of major importance in human homeostasis. Much attention has been given to the
cutaneous response to intense or even noxious various stimuli, such as thermal stress [2], ...
Cited by 42 - Related articles - All 5 versions

Progressive calibrated pressure device to measure cutaneous blood flow changes …


B Fromy, P Abraham, JL Saumet - Brain Research Protocols, 2000 - Elsevier
The present methodological paper describes the mechanical devices, the difficulties, the time
required, the possibilities and limitations of the technique to apply a progressive calibrated pressure
and to simultaneously measure cutaneous blood flow with laser Doppler probe at the ...
Cited by 26 - Related articles - All 3 versions

Dynamics of local pressure-induced cutaneous vasodilation in the human hand


P Abraham, B Fromy, S Merzeau, A Jardel, JL … - Microvascular Research, 2001 - Elsevier
We recently demonstrated that a pressure-induced vasodilation results from local nonnociceptive
stimulation of the skin of the human hand. We aimed to test the hypothesis that this vasodilation
was not a short-lived response to a single type of pressure strain, but could be a widely ...
Cited by 24 - Related articles - BL Direct - All 5 versions

Impaired pressure-induced vasodilation at the foot in young adults with type 1 …

- diabetesjournals.org
A Koı̈tka, P Abraham, B Bouhanick, D Sigaudo- … - Diabetes, 2004 - Am Diabetes Assoc
Vascular and neurological mechanisms are both likely to be involved in foot ulcer. We recently
reported a pressure-induced vasodilation (PIV), relying on unmyelinated afferent excitation. We
previously found that cutaneous blood flow in response to locally applied pressure might ...
Cited by 34 - Related articles - BL Direct - All 4 versions

Effect of isoflurane on skin-pressure-induced vasodilation


L Fizanne, B Fromy, MP Preckel, D Sigaudo- … - Journal of Vasc …, 2003 - content.karger.com
Since general anesthesia has been shown to attenuate endothelium-dependent
vasodilation, it was of interest to verify whether general anesthesia would modify skin vasodilation
in response to local pressure application, which is endothelium dependent. To study the ...
Cited by 13 - Related articles - BL Direct - All 5 versions

Early endothelial dysfunction severely impairs skin blood flow response to local …


D Sigaudo-Roussel, C Demiot, B Fromy, A Koïtka, G … - Diabetes, 2004 - Am Diabetes Assoc
Pressure-induced vasodilation (PIV) is a mechanism whereby skin blood flow increases in response
to progressive locally applied pressure. Skin blood flow in response to applied pressure decreased
early in diabetic patients as a result of vascular and/or neural impairment. This study was ...
Cited by 20 - Related articles - BL Direct - All 5 versions

Preservation of pressure-induced cutaneous vasodilation by limiting oxidative …

- oxfordjournals.org
C Demiot, B Fromy, JL Saumet, D … - Cardiovascular …, 2006 - cardiovascres.oxfordjournals.org
Methods and results: Diabetic mice received no treatment or a daily treatment with either
sorbinil, alagebrium or alpha-lipoic acid (LPA) for 1 week. Laser Doppler flowmetry was used
to evaluate PIV as well as endothelium-dependent vasodilation following iontophoretic ...
Cited by 8 - Related articles - All 7 versions

Low skin temperature impairs the cutaneous vasodilator response to local …


A Koı̈tka, MS Legrand-Fernandez, P Abraham, L … - Microvascular Research, 2004 - Elsevier
A pressure-induced vasodilation (PIV) was recently reported as a putative protective response
in human skin. Therefore, we examined the influence of skin temperatures on cutaneous blood
flow responses to local progressive pressure strain. Ten healthy volunteers were studied ...
Cited by 8 - Related articles - All 3 versions


Result Page: 

1

2

3

4

5

6

7

8

9

10

Next


 


Go to Google Home - About Google - About Google Scholar

©2009 Google