NH WHITE, D SKOR, JV SANTIAGO - Annals of Internal Medicine, 1982 - Am Coll Physicians We evaluated a practical closed-loop system of insulin delivery consisting of hourly blood glucose
determinations using glucose oxidase reagent strips and an intravenous infusion of insulin controlled
by a commonly available controller. In 25 insulin-dependent diabetic subjects, this system ... Cited by 72 - Related articles - All 2 versions
PC Davidson, RD Steed, BW Bode - Diabetes Care, 2005 - Am Diabetes Assoc RESEARCH DESIGN AND METHODS — A computer-directed algorithm for advice on the delivery
of intravenous insulin that is flexible in blood glucose timing and advises insulin dosing in a graduated
manner has been developed. This software program, known as the Glucommander, has ... Cited by 82 - Related articles - BL Direct - All 4 versions
- ►aace.com [PDF] BW Bode, SS Braithwaite, RD Steed, PC Davidson - Endocrine Practice, 2004 - AACE The medical literature supports the use of intravenous (IV) insulin infusion in preference to the
subcutaneous (SC) route of insulin administration for several clinical indications, including diabetic
ketoacidosis and nonketot- ic hyperosmolar state (1,2), critical care illness (3-5), ... Cited by 80 - Related articles - BL Direct - All 3 versions
- ►endojournals.org CS Mao, ME Riegelhuth, D Van Gundy, C … - Journal of Clinical …, 1997 - Endocrine Soc Initial insulin requirements in noninsulin-dependent diabetes mellitus (NIDDM) are difficult to
estimate because of individual variability in insulin sensitivity and secretion. We evaluated a
simple, nurse-managed algorithm for overnight delivery of insulin, for its ability to provide ... Cited by 13 - Related articles - BL Direct - All 4 versions
M Mokan, JE Gerich - Journal of Clinical Endocrinology & Metabolism, 1992 - Endocrine Soc F OR INITIATING intensive insulin therapy and for certain research protocols, it is often desirous
to have a diabetic patient euglycemic in the morning. Over- night infusion of insulin with closed
loop devices (eg Biostator) have been used for these purposes (1, 2). In addition, ... Cited by 28 - Related articles - All 3 versions
JB Hawkins, Jr, MD, CM Morales, BSN, CDE, JC Shipp, … - Endocrine Practice, 1995 - AACE The purpose of this study was to determine the sub- cutaneous insulin requirements for
rapid, effective regula- tion of blood glucose in patients with poorly controlled type II diabetes
mellitus by using an intravenous insulin infusion protocol. The insulin infusion achieved a ... Cited by 16 - Related articles - All 2 versions
[CITATION] Evaluation of the glucose management system (GMS) for administering IV insulin …
NB Watts, SS Gebhart, RV Clark, LS Phillips - Diabetes Care, 1987 - Am Diabetes Assoc An algorithm was developed to determine whether an individualized insulin infusion could maintain
plasma glucose in a desirable steady state after surgery. In 24 patients, insulin was provided
according to a "glucose-feedback" formula to maintain plasma glucose between 120 and ... Cited by 66 - Related articles - All 5 versions