Follow
Biplab Sarkar
Biplab Sarkar
Chief Medical Physicist, Apollo Multispeciality Hospitals, Kolkata
Verified email at apollohospitals.com - Homepage
Title
Cited by
Cited by
Year
Quality assurance of dynamic parameters in volumetric modulated arc therapy
A Manikandan, B Sarkar, R Holla, TR Vivek, N Sujatha
The British Journal of Radiology 85 (1015), 1002-1010, 2012
432012
Relative dosimetrical verification in high dose rate brachytherapy using two-dimensional detector array IMatriXX
A Manikandan, S Biplab, PA David, R Holla, TR Vivek, N Sujatha
Journal of medical physics 36 (3), 171-175, 2011
292011
A mathematical approach to beam matching
B Sarkar, A Manikandan, M Nandy, MS Gossman, CS Sureka, A Ray, ...
The British journal of radiology 86 (1031), 20130238, 2013
242013
Short tangential arcs in VMAT based breast and chest wall radiotherapy lead to conformity of the breast dose with lesser cardiac and lung doses: a prospective study of breast …
A Munshi, B Sarkar, S Anbazhagan, UK Giri, H Kaur, K Jassal, T Ganesh, ...
Australasian physical & engineering sciences in medicine 40, 729-736, 2017
232017
A low gradient junction technique of craniospinal irradiation using volumetric-modulated arc therapy and its advantages over the conventional therapy
B Sarkar, A Munshi, A Manikandan, S Roy, T Ganesh, BK Mohanti, ...
Cancer/Radiothérapie 22 (1), 62-72, 2018
222018
Spatial orientation of coronary arteries and its implication for breast and thoracic radiotherapy—proposing “coronary strip” as a new organ at risk
A Munshi, N Khataniar, B Sarkar, ML Bera, BK Mohanti
Strahlentherapie und Onkologie 194 (8), 711-718, 2018
202018
Dose fall-off patterns with volumetric modulated arc therapy and three-dimensional conformal radiotherapy including the “organ at risk” effect. Experience of linear accelerator …
A Munshi, B Sarkar, S Roy, T Ganesh, BK Mohanti
Cancer/Radiothérapie 23 (2), 138-146, 2019
182019
Methodology to reduce 6D patient positional shifts into a 3D linear shift and its verification in frameless stereotactic radiotherapy
B Sarkar, J Ray, T Ganesh, A Manikandan, A Munshi, S Rathinamuthu, ...
Physics in Medicine & Biology 63 (7), 075004, 2018
172018
Do technological advances in linear accelerators improve dosimetric outcomes in stereotaxy? A head-on comparison of seven linear accelerators using volumetric modulated arc …
B Sarkar, A Pradhan, A Munshi
Indian Journal of Cancer 53 (1), 166-173, 2016
172016
Dosimetric comparison between conventional and conformal radiotherapy for carcinoma cervix: Are we treating the right volumes?
J Goswami, NB Patra, B Sarkar, A Basu, S Pal
South Asian Journal of Cancer 2 (3), 128, 2013
172013
Dosimetric comparison of short and full arc in spinal PTV in volumetric-modulated arc therapy-based craniospinal irradiation
B Sarkar, A Munshi, T Ganesh, A Manikandan, BK Mohanti
Medical Dosimetry 45 (1), 1-6, 2020
142020
Small bowel toxicity in pelvic radiotherapy for postoperative gynecological cancer: comparison between conformal radiotherapy and intensity modulated radiotherapy
A Ray, B Sarkar
Asia‐Pacific Journal of Clinical Oncology 9 (3), 280-284, 2013
142013
Optimized point dose measurement for monitor unit verification in intensity modulated radiation therapy using 6 MV photons by three different methodologies with different …
B Sarkar, B Ghosh, S Mahendramohan, A Basu, J Goswami, A Ray
Journal of Medical Physics 35 (3), 144-150, 2010
132010
Rotational positional error corrected intrafraction set‐up margins in stereotactic radiotherapy: a spatial assessment for coplanar and noncoplanar geometry
B Sarkar, A Munshi, T Ganesh, A Manikandan, S Krishnankutty, L Chitral, ...
Medical Physics 46 (11), 4749-4754, 2019
122019
Standardization of volumetric modulated arc therapy‐based frameless stereotactic technique using a multidimensional ensemble‐aided knowledge‐based planning
B Sarkar, A Munshi, T Ganesh, A Manikandan, SK Anbazhagan, ...
Medical Physics 46 (5), 1953-1962, 2019
122019
A homogeneous water-equivalent anthropomorphic phantom for dosimetric verification of radiotherapy plans
M Arjunan, SC Sekaran, B Sarkar, S Manikandan
Journal of Medical Physics 43 (2), 100-105, 2018
122018
Detector system dose verification comparisons for arc therapy: couch vs. gantry mount
A Manikandan, B Sarkar, M Nandy, CS Sureka, MS Gossman, N Sujatha, ...
Journal of applied clinical medical physics 15 (3), 41-53, 2014
122014
Rotational positional error-corrected linear set-up margin calculation technique for lung stereotactic body radiotherapy in a dual imaging environment of 4-D cone beam CT and …
B Sarkar, T Ganesh, A Munshi, A Manikandan, S Roy, S Krishnankutty, ...
La radiologia medica 126 (7), 979-988, 2021
112021
Positional errors in linear accelerator based frameless cranial stereotaxy: A note of caution.
B Sarkar, A Munshi, S Krishnankutty, T Ganesh, K Mohanti
Journal of BU ON.: Official Journal of the Balkan Union of Oncology 22 (6 …, 2017
102017
Choice of appropriate beam model and gantry rotational angle for low-dose gradient-based craniospinal irradiation using volumetric-modulated arc therapy
B Sarkar, A Pradhan
Journal of Radiotherapy in Practice 16 (1), 53-64, 2017
92017
The system can't perform the operation now. Try again later.
Articles 1–20