Follow
Ivana Drobnjak
Ivana Drobnjak
Professor of Computational Healthcare, University College London
Verified email at ucl.ac.uk
Title
Cited by
Cited by
Year
Advances in functional and structural MR image analysis and implementation as FSL
SM Smith, M Jenkinson, ..., I Drobnjak, ..., PM Matthews
Neuroimage 23, S208-S219, 2004
145212004
Changes in connectivity profiles define functionally distinct regions in human medial frontal cortex
H Johansen-Berg, TEJ Behrens, MD Robson, I Drobnjak, ..., PM Matthews
Proceedings of the National Academy of Sciences 101 (36), 13335-13340, 2004
7752004
Towards a comprehensive framework for movement and distortion correction of diffusion MR images: Within volume movement
JLR Andersson, MS Graham, I Drobnjak, H Zhang, N Filippini, M Bastiani
Neuroimage 152, 450-466, 2017
3332017
Conventions and nomenclature for double diffusion encoding NMR and MRI
N Shemesh, SN Jespersen, ..., I Drobnjak, ..., CF Westin
Magnetic resonance in medicine 75 (1), 82-87, 2016
2422016
Resolution limit of cylinder diameter estimation by diffusion MRI: The impact of gradient waveform and orientation dispersion
M Nilsson, S Lasič, I Drobnjak, D Topgaard, CF Westin
NMR in Biomedicine 30 (7), e3711, 2017
1632017
PGSE, OGSE, and sensitivity to axon diameter in diffusion MRI: Insight from a simulation study
I Drobnjak, H Zhang, A Ianuş, E Kaden, DC Alexander
Magnetic resonance in medicine 75 (2), 688-700, 2016
1382016
Development of a functional magnetic resonance imaging simulator for modeling realistic rigid‐body motion artifacts
I Drobnjak, D Gavaghan, E Süli, J Pitt‐Francis, M Jenkinson
Magnetic Resonance in Medicine: An Official Journal of the International …, 2006
1262006
Realistic simulation of artefacts in diffusion MRI for validating post-processing correction techniques
MS Graham, I Drobnjak, H Zhang
NeuroImage 125, 1079-1094, 2016
1242016
Susceptibility-induced distortion that varies due to motion: Correction in diffusion MR without acquiring additional data
JLR Andersson, MS Graham, I Drobnjak, H Zhang, J Campbell
Neuroimage 171, 277-295, 2018
1212018
Optimizing gradient waveforms for microstructure sensitivity in diffusion-weighted MR
I Drobnjak, B Siow, DC Alexander
Journal of Magnetic Resonance 206 (1), 41-51, 2010
1162010
Machine learning based compartment models with permeability for white matter microstructure imaging
GL Nedjati-Gilani, ..., I Drobnjak, CAMG Wheeler-Kingshott, DC Alexander
NeuroImage 150, 119-135, 2017
1032017
Quantitative assessment of the susceptibility artefact and its interaction with motion in diffusion MRI
MS Graham, I Drobnjak, M Jenkinson, H Zhang
PloS one 12 (10), e0185647, 2017
932017
Quality assessment of ambulatory ECG using wavelet entropy of the HRV signal
C Orphanidou, I Drobnjak
IEEE journal of biomedical and health informatics 21 (5), 1216-1223, 2016
692016
Gaussian phase distribution approximations for oscillating gradient spin echo diffusion MRI
A Ianuş, B Siow, I Drobnjak, H Zhang, DC Alexander
Journal of magnetic resonance 227, 25-34, 2013
692013
Accurate estimation of microscopic diffusion anisotropy and its time dependence in the mouse brain
A Ianuş, SN Jespersen, TS Duarte, DC Alexander, I Drobnjak, N Shemesh
Neuroimage 183, 934-949, 2018
662018
The matrix formalism for generalised gradients with time-varying orientation in diffusion NMR
I Drobnjak, H Zhang, MG Hall, DC Alexander
Journal of Magnetic Resonance 210 (1), 151-157, 2011
662011
Model‐based estimation of microscopic anisotropy using diffusion MRI: a simulation study
A Ianuş, I Drobnjak, DC Alexander
NMR in Biomedicine 29 (5), 672-685, 2016
512016
A supervised learning approach for diffusion MRI quality control with minimal training data
MS Graham, I Drobnjak, H Zhang
NeuroImage 178, 668-676, 2018
492018
Estimation of pore size in a microstructure phantom using the optimised gradient waveform diffusion weighted NMR sequence
B Siow, I Drobnjak, A Chatterjee, MF Lythgoe, DC Alexander
Journal of Magnetic Resonance 214, 51-60, 2012
462012
Simulating the effects of time-varying magnetic fields with a realistic simulated scanner
I Drobnjak, GS Pell, M Jenkinson
Magnetic resonance imaging 28 (7), 1014-1021, 2010
442010
The system can't perform the operation now. Try again later.
Articles 1–20