Follow
Claire Foottit
Claire Foottit
The Ottawa Hospital
Verified email at toh.ca
Title
Cited by
Cited by
Year
Preoperative prognostic value of dynamic contrast-enhanced MRI–derived contrast transfer coefficient and plasma volume in patients with cerebral gliomas
TB Nguyen, GO Cron, JF Mercier, C Foottit, CH Torres, S Chakraborty, ...
American Journal of Neuroradiology 36 (1), 63-69, 2015
582015
Comparison of the diagnostic accuracy of DSC-and dynamic contrast-enhanced MRI in the preoperative grading of astrocytomas
TB Nguyen, GO Cron, K Perdrizet, K Bezzina, CH Torres, S Chakraborty, ...
American Journal of Neuroradiology 36 (11), 2017-2022, 2015
532015
Diagnostic accuracy of dynamic contrast-enhanced MR imaging using a phase-derived vascular input function in the preoperative grading of gliomas
TB Nguyen, GO Cron, JF Mercier, C Foottit, CH Torres, S Chakraborty, ...
American Journal of Neuroradiology 33 (8), 1539-1545, 2012
472012
Determination of the venous output function from MR signal phase: Feasibility for quantitative DCE‐MRI in human brain
C Foottit, GO Cron, MJ Hogan, TB Nguyen, I Cameron
Magnetic resonance in medicine 63 (3), 772-781, 2010
432010
Arterial input functions determined from MR signal magnitude and phase for quantitative dynamic contrast‐enhanced MRI in the human pelvis
GO Cron, C Foottit, TE Yankeelov, LI Avruch, ME Schweitzer, I Cameron
Magnetic resonance in medicine 66 (2), 498-504, 2011
342011
Can we rely on surgical clips placed during oncoplastic breast surgery to accurately delineate the tumor bed for targeted breast radiotherapy?
G Aldosary, JM Caudrelier, A Arnaout, L Chang, T Tse, C Foottit, J Song, ...
Breast Cancer Research and Treatment 186, 343-352, 2021
112021
Radiological, dosimetric and mechanical properties of a deformable breast phantom for radiation therapy and surgical applications
G Aldosary, T Tse, A Arnaout, JM Caudrelier, C Czyrnyj, R Romain, ...
Biomedical physics & engineering express 6 (3), 035028, 2020
62020
Optimizing perfusion imaging of brain tumors: Validation of venous output function used as a surrogate AIF
C Foottit, GO Cron, JF Mercier, TV Nguyen, I Cameron, ME Schweitzer, ...
19th Proceedings of the international society for magnetic resonance in …, 2011
62011
Accurate noise bias correction applied to individual pixels
A Cardenas-Blanco, M Nezamzadeh, C Foottit, I Cameron
Proceedings of the International Society of Magnetic Resonance in Medicine 3 …, 2007
52007
Geometric inaccuracy and co-registration errors for CT, DynaCT and MRI images used in robotic stereotactic radiosurgery treatment planning
G Aldosary, J Szanto, O Holmes, B Lavigne, W Althobaity, A Sheikh, ...
Physica Medica 69, 212-222, 2020
42020
A comparison of arterial input functions derived from phase and magnitude for quantitative DCE-MRI of the prostate
G Cron, C Foottit, T Yankeelov, L Avruch, I Cameron
Proceedings of the 17th Annual Scientific Meeting of ISMRM, Honolulu 2248, 2009
32009
Canadian Surgery Forum 201901. The future of general surgery training: a Canadian resident nationwide Delphi consensus statement02. Traumatized: Can mindfulness lead to …
C Huynh, E Clement, D DeGirolamo, A Kleiman, R Ralph-Edwards, ...
Canadian journal of surgery 62 (4 Suppl 2), S89-S169, 2019
12019
Improved venous output function using MR signal phase for quantitative 2D DCE-MRI in human brain
C Foottit, GO Cron, TB Nguyen, MJ Hogan, I Cameron
Proceedings of the 18th Annual Meeting of ISMRM, 1719, 2010
12010
Dosimetric considerations for moldable silicone composites used in radiotherapy applications
G Aldosary, J Belec, C Foottit, E Vandervoort
Journal of Applied Clinical Medical Physics 23 (6), e13605, 2022
2022
Contamination Resulting From a Broken 125I Seed During a Brachytherapy Procedure
L Buckley, DJ Fraser, M MacPherson, C Foottit
Health Physics 121 (5), 531-534, 2021
2021
Dosimetric Considerations of Modable Silicones for Radiotherapy Boluses and Phantoms
G Aldosary, J Belec, C Foottit, E Vandervoort
MEDICAL PHYSICS 48 (6), 2021
2021
Multicenter Characterization of MRIs Used for Radiation Therapy: The Collaborative Quality Assurance Program
L Conroy, C Foottit, B Zhang, A Elzibak, R Hunter, P Rapley, ...
MEDICAL PHYSICS 47 (6), E431-E431, 2020
2020
Investigation of Tumor Bed Delineation Accuracy for Targeted Breast Radiation Therapy Following Oncoplastic Surgery
G Aldosary, J Caudrelier, T Tse, A Arnaout, C Foottit, J Belec, ...
MEDICAL PHYSICS 47 (6), E372-E372, 2020
2020
Radiological and Dosimetric Characterization of a CT, MRI and Ultrasound Customizable Breast Phantom for Radiotherapy Use and Surgical Practice
G Aldosary, T Tse, W Lee, T Alotaibi, C Foottit, A Arnaout, J Caudrelier, ...
MEDICAL PHYSICS 46 (6), E450-E450, 2019
2019
International multi-institutional bench mark study on dosimetric and volumetric modulation using helical tomotherapy treatment planning for malignant pleural mesothelioma tumors
A Movahed, T Knöös, C Foottit, A Haraldsson, D Verellen, K Tournel, S Qi, ...
World Congress on Medical Physics and Biomedical Engineering, June 7-12 …, 2015
2015
The system can't perform the operation now. Try again later.
Articles 1–20