Follow
Juan J. Rovira-Escutia
Juan J. Rovira-Escutia
Consorci Hospital General Universitari de València
Verified email at radiochromic.com
Title
Cited by
Cited by
Year
Dose variations in tumor volumes and organs at risk during IMRT for head‐and‐neck cancer
M Beltran, M Ramos, JJ Rovira-Escutia, S Perez‐Hoyos, M Sancho, ...
Journal of applied clinical medical physics 13 (6), 101-111, 2012
782012
Eye lens dose in interventional cardiology
S Principi, C Delgado Soler, M Ginjaume, M Beltran Vilagrasa, ...
Radiation protection dosimetry 165 (1-4), 289-293, 2015
572015
Occupational eye lens doses in interventional cardiology. A multicentric study
RM Sánchez, E Vano, JM Fernández, X Pifarré, JM Ordiales, ...
Journal of Radiological Protection 36 (1), 133, 2016
272016
A protocol for accurate radiochromic film dosimetry using Radiochromic. com
I Méndez, JJ Rovira-Escutia, B Casar
Radiology and Oncology 55 (3), 369-378, 2021
112021
Estudio piloto de una auditoría postal dosimétrica para radioterapia en condiciones de referencia
MC Pujades-Claumarchirant, C Candela-Juan, L Oliver-Cañamás, ...
Revista de Física Médica 23 (1), 27-34, 2022
32022
A User-Friendly System for Mailed Dosimetric Audits of 192Ir or 60Co HDR Brachytherapy Sources
L Oliver-Cañamás, J Vijande, C Candela-Juan, J Gimeno-Olmos, ...
Cancers 15 (9), 2484, 2023
22023
Embedded bleeding detector into a PMMA applicator for electron intraoperative radiotherapy
R Garcia-Gil, S Casans, AE Navarro, AJ García-Sánchez, ...
Physica Medica 94, 35-42, 2022
22022
A system for mailed dosimetric audits of 192Ir and 60Co HDR brachytherapy combining OSLD and radiochromic film
L Oliver-Cañamás, JJ Rovira-Escutia, J Vijande, C Candela-Juan, ...
Radiation Measurements, 107101, 2024
2024
Monte Carlo flattening filter design to high energy intraoperative electron beam homogenization
S Oliver, J Vijande, N Tejedor-Aguilar, R Miró, JJ Rovira-Escutia, ...
Radiation Physics and Chemistry 212, 111102, 2023
2023
PO-2181 Studies performed for the characterization of a mailed dosimetric audit of HDR Brachytherapy
LO Canamas, J Vijande-Asenjo, C Candela-Juan, J Gimeno-Olmos, ...
Radiotherapy and Oncology 182, S1964-S1965, 2023
2023
Validation of Radiochromic.com Gamma Analysis Software
I Mendez, JJ Rovira-Escutia, B Casar
MEDICAL PHYSICS 48 (6), 2021
2021
Dose to patients and professionals in cardiology interventional: Progress of multicenter group Doccaci
RM Sanchez, E Vano, JM Fernandez, R Goicolea, X Pifarre, J Escaned, ...
III Joint Congress Spanish Societies of Medical Physics and Radiation …, 2013
2013
EP-1404 CT ARTIFACTS EFFECT IN SIB-IMRT CONTOURING AND PLANNING FOR PROSTATE CANCER PATIENTS WITH BILATERAL HIP PROSTHESES
J Saez, XM Pijoan, JJ Rovira, MH Lopez, I Toribio, M Sancho, R Vergés
Radiotherapy and Oncology 103, S533-S534, 2012
2012
EP-1540 COMPARISON OF THREE SIB-IMRT PLANNING TECHNIQUES FOR PROSTATE CANCER PATIENTS WITH BILATERAL HIP PROSTHESES
MH Lopez, X Maldonado, M Sancho, J Sáez, JJ Rovira, I Toribio
Radiotherapy and Oncology 103, S591, 2012
2012
CLINICAL PROSPECTIVE STUDY OF VOLUME AND DOSIMETRIC CHANGES DURING FRACTIONATED RADIOTHERAPY FOR LOCALLY ADVANCED HEAD AND NECK CANCER
MR Albiac, JJ Rovira, EP Calvo, S Benavente, M Beltran, J Giralt
Radiotherapy and Oncology 98, S37, 2011
2011
CRITERIA FOR REPLANNING HEAD AND NECK CANCER PATIENTS UNDERGOING 3DCRT AND IMRT
M Beltran, JJ Rovira, M Sancho, M Ramos, S Perez-Hoyos, S Benavente, ...
RADIOTHERAPY AND ONCOLOGY 96, S312-S312, 2010
2010
COMPARISON OF THREE DYNAMIC IMRT DOSIMETRIC VERIFICATION SYSTEMS.
X Fa, N Sanchez, M Beltran, A Seoane, M Hermida Lopez, JJ Rovira, ...
RADIOTHERAPY AND ONCOLOGY 96, S452-S452, 2010
2010
Does electronic portal image device really impact set-up practice? A first step introducing a displacement correction protocol and PTV margin re-design
X Maldonado, JJ Rovira, J Saez, M Molla, V Reyes, E Puertas, I Giraldo, ...
EJC supplements, 2009
2009
Comparison of three SIB-IMRT planning techniques for prostate cancer patients with bilateral hip prostheses
M Hermida, X Maldonado, M Sancho, J Sáez, JJ Rovira, I Toribio
The system can't perform the operation now. Try again later.
Articles 1–19