Follow
N.Fouda
N.Fouda
Mansoura University Faculty of Engineering Associate Professor of Production Engineering
Verified email at mans.edu.eg
Title
Cited by
Cited by
Year
Modified porosity model in analysis of functionally graded porous nanobeams
MA Eltaher, N Fouda, T El-midany, AM Sadoun
Journal of the Brazilian Society of Mechanical Sciences and Engineering 40, 1-10, 2018
1012018
Improved design of cementless hip stems using two‐dimensional functionally graded materials
HS Hedia, MAN Shabara, TT El‐Midany, N Fouda
Journal of Biomedical Materials Research Part B: Applied Biomaterials: An …, 2006
612006
Bending, buckling and vibration of a functionally graded porous beam using finite elements
N Fouda, T El-Midany, AM Sadoun
Journal of applied and computational mechanics 3 (4), 274-282, 2017
542017
A method of material optimization of cementless stem through functionally graded material
HS Hedia, MAN Shabara, TT El-Midany, N Fouda
International Journal of Mechanics and Materials in Design 1, 329-346, 2004
532004
New crack stop hole shape using structural optimizing technique
M Fanni, N Fouda, MAN Shabara, M Awad
Ain Shams Engineering Journal 6 (3), 987-999, 2015
412015
A new design of cemented stem using functionally graded materials (FGM)
HS Hedia, SM Aldousari, AK Abdellatif, N Fouda
Bio-medical materials and engineering 24 (3), 1575-1588, 2014
402014
Design optimization of cementless hip prosthesis coating through functionally graded material
HS Hedia, N Fouda
Computational Materials Science 87, 83-87, 2014
382014
Numerical study of stress shielding reduction at fractured bone using metallic and composite bone-plate models
N Fouda, R Mostafa, A Saker
Ain Shams Engineering Journal 10 (3), 481-488, 2019
342019
Development of cementless metal-backed acetabular cup prosthesis using functionally graded material
HS Hedia, TT El-Midany, MAN Shabara, N Fouda
International Journal of Mechanics and Materials in Design 2, 259-267, 2005
282005
Shape optimization of metal backing for cemented acetabular cup
HS Hedia, AAA Abdel‐Shafi, N Fouda
Bio-Medical Materials and Engineering 10 (2), 73-82, 2000
192000
Improved stress shielding on a cementless tibia tray using functionally graded material
HS Hedia, N Fouda
Materials Testing 55 (11-12), 845-851, 2013
152013
Comparison of Functionally Graded Hip Stem Implants with‎ Various Second-Generation Titanium Alloys
TA Enab, N Fouda, I Eldesouky
Journal of Applied and Computational Mechanics, 2020
13*2020
Stress shielding reduction via graded porosity of a femoral stem implant
HS Hedia, SM Aldousari, HA Timraz, N Fouda
Materials Testing 61 (7), 695-704, 2019
132019
Influence of different nanomaterials on the mechanical properties of epoxy matrix composites
SM Aldousari, HS Hedia, FWH Al Thobiani, N Fouda
Materials Testing 60 (6), 639-646, 2018
122018
Horizontal functionally graded material coating of cementless hip prosthesis
N Fouda
Trends Biomater. Artif. Organs 28 (2), 58-64, 2014
122014
The effect of elastic modulus of the backing material on the fatigue notch factor and stress
HS Hedia, AAA Abdl‐Shafi, N Fouda
Bio-medical materials and engineering 10 (3-4), 141-156, 2000
122000
Numerical evaluation of a porous tibial-knee implant using gyroid structure
B Eltlhawy, N Fouda, I Eldesouky
Journal of Biomedical Physics & Engineering 12 (1), 75, 2022
112022
Evaluating the coating process of titanium dioxide nanoparticles and sodium tripolyphosphate on cucumbers under chilling condition to extend the shelf-life
M Helal, R Sami, E Khojah, A Elhakem, N Benajiba, AAM Al-Mushhin, ...
Scientific Reports 11 (1), 20312, 2021
102021
The effect of shape optimization and bimaterial stem on increasing the performance of a cemented tibia
N Fouda
International Journal of Mechaninal and Mechatronics Engineering, 2014
82014
A new design of dental implant coating using functionally graded material
HS Hedia, N Fouda
Materials Testing 55 (10), 765-771, 2013
82013
The system can't perform the operation now. Try again later.
Articles 1–20