Modified porosity model in analysis of functionally graded porous nanobeams MA Eltaher, N Fouda, T El-midany, AM Sadoun Journal of the Brazilian Society of Mechanical Sciences and Engineering 40, 1-10, 2018 | 101 | 2018 |
Improved design of cementless hip stems using two‐dimensional functionally graded materials HS Hedia, MAN Shabara, TT El‐Midany, N Fouda Journal of Biomedical Materials Research Part B: Applied Biomaterials: An …, 2006 | 61 | 2006 |
Bending, buckling and vibration of a functionally graded porous beam using finite elements N Fouda, T El-Midany, AM Sadoun Journal of applied and computational mechanics 3 (4), 274-282, 2017 | 54 | 2017 |
A method of material optimization of cementless stem through functionally graded material HS Hedia, MAN Shabara, TT El-Midany, N Fouda International Journal of Mechanics and Materials in Design 1, 329-346, 2004 | 53 | 2004 |
New crack stop hole shape using structural optimizing technique M Fanni, N Fouda, MAN Shabara, M Awad Ain Shams Engineering Journal 6 (3), 987-999, 2015 | 41 | 2015 |
A new design of cemented stem using functionally graded materials (FGM) HS Hedia, SM Aldousari, AK Abdellatif, N Fouda Bio-medical materials and engineering 24 (3), 1575-1588, 2014 | 40 | 2014 |
Design optimization of cementless hip prosthesis coating through functionally graded material HS Hedia, N Fouda Computational Materials Science 87, 83-87, 2014 | 38 | 2014 |
Numerical study of stress shielding reduction at fractured bone using metallic and composite bone-plate models N Fouda, R Mostafa, A Saker Ain Shams Engineering Journal 10 (3), 481-488, 2019 | 34 | 2019 |
Development of cementless metal-backed acetabular cup prosthesis using functionally graded material HS Hedia, TT El-Midany, MAN Shabara, N Fouda International Journal of Mechanics and Materials in Design 2, 259-267, 2005 | 28 | 2005 |
Shape optimization of metal backing for cemented acetabular cup HS Hedia, AAA Abdel‐Shafi, N Fouda Bio-Medical Materials and Engineering 10 (2), 73-82, 2000 | 19 | 2000 |
Improved stress shielding on a cementless tibia tray using functionally graded material HS Hedia, N Fouda Materials Testing 55 (11-12), 845-851, 2013 | 15 | 2013 |
Comparison of Functionally Graded Hip Stem Implants with Various Second-Generation Titanium Alloys TA Enab, N Fouda, I Eldesouky Journal of Applied and Computational Mechanics, 2020 | 13* | 2020 |
Stress shielding reduction via graded porosity of a femoral stem implant HS Hedia, SM Aldousari, HA Timraz, N Fouda Materials Testing 61 (7), 695-704, 2019 | 13 | 2019 |
Influence of different nanomaterials on the mechanical properties of epoxy matrix composites SM Aldousari, HS Hedia, FWH Al Thobiani, N Fouda Materials Testing 60 (6), 639-646, 2018 | 12 | 2018 |
Horizontal functionally graded material coating of cementless hip prosthesis N Fouda Trends Biomater. Artif. Organs 28 (2), 58-64, 2014 | 12 | 2014 |
The effect of elastic modulus of the backing material on the fatigue notch factor and stress HS Hedia, AAA Abdl‐Shafi, N Fouda Bio-medical materials and engineering 10 (3-4), 141-156, 2000 | 12 | 2000 |
Numerical evaluation of a porous tibial-knee implant using gyroid structure B Eltlhawy, N Fouda, I Eldesouky Journal of Biomedical Physics & Engineering 12 (1), 75, 2022 | 11 | 2022 |
Evaluating the coating process of titanium dioxide nanoparticles and sodium tripolyphosphate on cucumbers under chilling condition to extend the shelf-life M Helal, R Sami, E Khojah, A Elhakem, N Benajiba, AAM Al-Mushhin, ... Scientific Reports 11 (1), 20312, 2021 | 10 | 2021 |
The effect of shape optimization and bimaterial stem on increasing the performance of a cemented tibia N Fouda International Journal of Mechaninal and Mechatronics Engineering, 2014 | 8 | 2014 |
A new design of dental implant coating using functionally graded material HS Hedia, N Fouda Materials Testing 55 (10), 765-771, 2013 | 8 | 2013 |