关注
Amar Aganovic
Amar Aganovic
在 uit.no 的电子邮件经过验证
标题
引用次数
引用次数
年份
Estimating the impact of indoor relative humidity on SARS-CoV-2 airborne transmission risk using a new modification of the Wells-Riley model
A Aganovic, Y Bi, G Cao, F Drangsholt, J Kurnitski, P Wargocki
Building and environment 205, 108278, 2021
612021
Do surgeons and surgical facilities disturb the clean air distribution close to a surgical patient in an orthopedic operating room with laminar airflow?
G Cao, MCA Storås, A Aganovic, LI Stenstad, JG Skogås
American Journal of Infection Control 46 (10), 1115-1122, 2018
612018
A systematic review of operating room ventilation
S Sadrizadeh, A Aganovic, A Bogdan, C Wang, A Afshari, A Hartmann, ...
Journal of Building Engineering 40, 102693, 2021
552021
Impact of surgical lights on the velocity distribution and airborne contamination level in an operating room with laminar airflow system
A Aganovic, G Cao, LI Stenstad, JG Skogås
Building and Environment 126, 42-53, 2017
532017
CFD study of the air distribution and occupant draught sensation in a patient ward equipped with protected zone ventilation
A Aganovic, M Steffensen, G Cao
Building and Environment 162, 106279, 2019
442019
Evaluation of airborne contaminant exposure in a single-bed isolation ward equipped with a protected occupied zone ventilation system
A Aganovic, G Cao
Indoor and built environment 28 (8), 1092-1103, 2019
282019
Cost-related analysis of implementing energy-efficient retrofit measures in the residential building sector of a middle-income country–A case study of Bosnia and Herzegovina
D Kadrić, A Aganovic, S Martinović, N Delalić, B Delalić-Gurda
Energy and Buildings 257, 111765, 2022
242022
Experimental study of the interaction between thermal plumes and human breathing in an undisturbed indoor environment
Z Cheng, C Guangyu, A Aganovic, L Baizhan
Energy and Buildings 207, 109587, 2020
232020
Ventilation design conditions associated with airborne bacteria levels within the wound area during surgical procedures: a systematic review
A Aganovic, G Cao, T Fecer, B Ljungqvist, B Lytsy, A Radtke, ...
Journal of Hospital Infection 113, 85-95, 2021
212021
New dose-response model and SARS-CoV-2 quanta emission rates for calculating the long-range airborne infection risk
A Aganovic, G Cao, J Kurnitski, P Wargocki
Building and Environment 228, 109924, 2023
202023
Experimental and simulated evaluations of airborne contaminant exposure in a room with a modified localized laminar airflow system
Z Cheng, A Aganovic, G Cao, Z Bu
Environmental Science and Pollution Research 28, 30642-30663, 2021
142021
Experimental study on the exposure level of surgical staff to SARS-CoV-2 in operating rooms with mixing ventilation under negative pressure
Y Bi, A Aganovic, HM Mathisen, G Cao
Building and Environment 217, 109091, 2022
122022
Modeling the impact of indoor relative humidity on the infection risk of five respiratory airborne viruses
A Aganovic, Y Bi, G Cao, J Kurnitski, P Wargocki
Scientific Reports 12 (1), 11481, 2022
102022
An experimental study on the effects of positioning medical equipment on contaminant exposure of a patient in an operating room with unidirectional downflow
A Aganovic, G Cao, LI Stenstad, JG Skogås
Building and Environment 165, 106096, 2019
102019
Airflow distribution for minimizing human exposure to airborne contaminants in healthcare facilities
A Aganovic
NTNU: Trondheim, Norway, 2019
102019
Zonal modeling of air distribution impact on the long-range airborne transmission risk of SARS-CoV-2
A Aganovic, G Cao, J Kurnitski, A Melikov, P Wargocki
Applied Mathematical Modelling 112, 800-821, 2022
92022
Multi-objective optimization of energy-efficient retrofitting strategies for single-family residential homes: Minimizing energy consumption, CO2 emissions and retrofit costs
D Kadrić, A Aganović, E Kadrić
Energy Reports 10, 1968-1981, 2023
62023
Post-COVID ventilation design: Infection risk-based target ventilation rates and point source ventilation effectiveness
J Kurnitski, M Kiil, A Mikola, KV Vosa, A Aganovic, P Schild, O Seppänen
Energy and Buildings 296, 113386, 2023
62023
Analysis of dynamical behaviour of the boiler room at Mechanical Engineering Faculty in Sarajevo in standard exploitation conditions.
A Aganovic
Institutt for energi-og prosessteknikk, 2013
62013
pH-dependent endocytosis mechanisms for influenza A and SARS-coronavirus
A Aganovic
Frontiers in Microbiology 14, 1190463, 2023
42023
系统目前无法执行此操作,请稍后再试。
文章 1–20