Follow
Ryan Chapman
Ryan Chapman
Assistant Professor, Department of Kinesiology, University of Rhode Island
Verified email at uri.edu - Homepage
Title
Cited by
Cited by
Year
Differences in hip–knee joint coupling during gait after anterior cruciate ligament reconstruction
TC Gribbin, LV Slater, CC Herb, JM Hart, RM Chapman, J Hertel, ...
Clinical Biomechanics 32, 64-71, 2016
392016
In vivo corrosion of modular dual-mobility implants: a retrieval study
JM Kolz, CC Wyles, DW Van Citters, RM Chapman, RT Trousdale, ...
The Journal of Arthroplasty 35 (11), 3326-3329, 2020
302020
Stance and swing phase knee flexion recover at different rates following total knee arthroplasty: An inertial measurement unit study
RM Chapman, WE Moschetti, DW Van Citters
Journal of biomechanics 84, 129-137, 2019
302019
Assessing shoulder biomechanics of healthy elderly individuals during activities of daily living using inertial measurement units: high maximum elevation is achievable but …
RM Chapman, MT Torchia, JE Bell, DW Van Citters
Journal of biomechanical engineering 141 (4), 041001, 2019
262019
Movement monitoring systems and methods
R Chapman, DW Van Citters, WE Moschetti, JE Bell
US Patent 10,463,279, 2019
242019
Achievement of target gain larger than unity in an inertial fusion experiment
H Abu-Shawareb, R Acree, P Adams, J Adams, B Addis, R Aden, P Adrian, ...
Physical Review Letters 132 (6), 065102, 2024
182024
Orthopedic leg alignment system and method
RM Chapman, DW Van Citters, G Goodchild
US Patent 10,828,175, 2020
152020
Effect of head size and rotation on taper corrosion in a hip simulator
CM Wight, CM Whyne, ER Bogoch, R Zdero, RM Chapman, ...
Bone & Joint Open 2 (11), 1004-1016, 2021
112021
Continuously Monitoring Shoulder Motion after Total Shoulder Arthroplasty: Maximum Elevation & Time Spent above 90° Elevation are Critical Metrics to Monitor
RM Chapman, MT Torchia, JE Bell, DW Van Citters
Journal of Shoulder and Elbow Surgery, 2019
112019
Developing a method for quantifying hip joint angles and moments during walking using neural networks and wearables
MV McCabe, DW Van Citters, RM Chapman
Computer Methods in Biomechanics and Biomedical Engineering 26 (1), 1-11, 2023
102023
Higher offset cross-linked polyethylene acetabular liners: is wear a significant clinical concern?
RM Chapman, DW Van Citters, D Chapman, DF Dalury
Hip International, 1-8, 2018
82018
Bilateral Femoral Component Fractures After Primary Total Knee Arthroplasty with Cruciate-Retaining Femoral Component
TA Nezwek, RM Chapman, AC Rothy, DW Van Citters, K Koenig
Arthroplasty Today 6 (3), 496-501, 2020
52020
Hip Joint Angles and Moments during Stair Ascent Using Neural Networks and Wearable Sensors
MV McCabe, DW Van Citters, RM Chapman
Bioengineering 10 (7), 784, 2023
32023
Is clinically measured knee range of motion after total knee arthroplasty ‘good enough?’: A feasibility study using wearable inertial measurement units to compare knee range of …
RM Chapman, WE Moschetti, DW Van Citters
Medicine in Novel Technology and Devices 11, 100085, 2021
32021
Using inertial measurement units to quantify shoulder elevation after reverse total shoulder arthroplasty: a pilot study comparing goniometric measures captured clinically to …
RM Chapman, MT Torchia, JE Bell, DW Van Citters
Seminars in Arthroplasty: JSES 33 (1), 85-93, 2023
22023
Utilizing Neural Networks and Wearables to Quantify Hip Joint Angles and Moments During Walking and Stair Ascent
MV McCabe
22020
A gyroscope-based system for intraoperative measurement of tibia coronal plane alignment in total knee arthroplasty
MA Kokko, RM Chapman, MW Roche, DW Van Citters
Medicine in Novel Technology and Devices 13, 100112, 2022
12022
Building Self-efficacy and Interest in Engineering Through Design
VV May, RM Chapman
2021 ASEE Virtual Annual Conference Content Access, 2021
12021
From Inertial Measurement Units (IMUs) to Physical Therapy (PT): The Use of Patient Biomechanics to Inform PT Prescription
RM Chapman
Dartmouth College, 2018
12018
Erratum to “A gyroscope-based system for intraoperative measurement of tibia coronal plane alignment in total knee arthroplasty”[Med Nov Technol Dev, 13, 2022, 100112]
MA Kokko, RM Chapman, MW Roche, DW Van Citters
Medicine in Novel Technology and Devices 21, 100281, 2024
2024
The system can't perform the operation now. Try again later.
Articles 1–20