Follow
M. Á. Ariza-Gracia
M. Á. Ariza-Gracia
Aragón Institute of Engineering Research (i3A)
Verified email at unizar.es
Title
Cited by
Cited by
Year
Coupled biomechanical response of the cornea assessed by non-contact tonometry. A simulation study
MÁ Ariza-Gracia, JF Zurita, DP Piñero, JF Rodriguez-Matas, B Calvo
PloS one 10 (3), e0121486, 2015
1022015
Automatized patient-specific methodology for numerical determination of biomechanical corneal response
MÁ Ariza-Gracia, J Zurita, DP Piñero, B Calvo, JF Rodríguez-Matas
Annals of biomedical engineering 44, 1753-1772, 2016
532016
Differences in corneo-scleral topographic profile between healthy and keratoconus corneas
DP Piñero, A Martínez-Abad, R Soto-Negro, P Ruiz-Fortes, ...
Contact Lens and Anterior Eye 42 (1), 75-84, 2019
402019
A predictive tool for determining patient-specific mechanical properties of human corneal tissue
MÁ Ariza-Gracia, S Redondo, DP Llorens, B Calvo, JFR Matas
Computer methods in applied mechanics and engineering 317, 226-247, 2017
302017
Template-based methodology for the simulation of intracorneal segment ring implantation in human corneas
J Flecha-Lescún, B Calvo, J Zurita, MÁ Ariza-Gracia
Biomechanics and modeling in mechanobiology 17 (4), 923-938, 2018
282018
Systematic study on the biomechanical stability of C-loop intraocular lenses: approach to an optimal design of the haptics
I Cabeza-Gil, MÁ Ariza-Gracia, L Remón, B Calvo
Annals of biomedical engineering 48, 1127-1136, 2020
202020
Fluid–structure simulation of a general non-contact tonometry. A required complexity?
MÁ Ariza-Gracia, W Wu, B Calvo, M Malvè, P Büchler, JFR Matas
Computer methods in applied mechanics and engineering 340, 202-215, 2018
172018
A numerical-experimental protocol to characterize corneal tissue with an application to predict astigmatic keratotomy surgery
MÁ Ariza-Gracia, Á Ortillés, JÁ Cristóbal, JFR Matas, B Calvo
Journal of the mechanical behavior of biomedical materials 74, 304-314, 2017
172017
Corneal biomechanics after intrastromal ring surgery: Optomechanical in silico assessment
MÁ Ariza-Gracia, J Flecha-Lescún, P Büchler, B Calvo
Translational vision science & technology 9 (11), 26-26, 2020
152020
Characterization of corneoscleral geometry using Fourier transform profilometry in the healthy eye
DP Piñero, A Martínez-Abad, R Soto-Negro, MA Ariza-Gracia, ...
Eye & contact lens 45 (3), 201-207, 2019
142019
Experimental and computational analysis of microbial inactivation in a solid by ohmic heating using pulsed electric fields
MÁ Ariza-Gracia, MP Cabello, G Cebrián, B Calvo, I Álvarez
Innovative Food Science & Emerging Technologies 65, 102440, 2020
122020
Geometrical characterization of the corneo-scleral transition in normal patients with Fourier domain optical coherence tomography
M Seguí-Crespo, MÁ Ariza-Gracia, NLD Sixpene, DP Piñero
International ophthalmology 39, 2603-2609, 2019
112019
Why non-contact tonometry tests cannot evaluate the effects of corneal collagen cross-linking
Á Ortillés, JF Rodríguez-Matas, MÁ Ariza-Gracia, G Pascual, B Calvo
Journal of Refractive Surgery 33 (3), 184-192, 2017
112017
Interaction between diurnal variations of intraocular pressure, pachymetry, and corneal response to an air puff: preliminary evidence
MA Ariza-Gracia, DP Piñero, JF Rodriguez, RJ Pérez-Cambrodí, B Calvo
JCRS Online Case Reports 3 (1), 12-15, 2015
62015
Personalized corneal biomechanics
MÁ Ariza-Gracia, J Flecha-Lescún, JFR Matas, BC Calzada
Advances in Biomechanics and Tissue Regeneration, 3-20, 2019
22019
Modeling and prediction of the immediate and short-term effect of myopic orthokeratology
A Sánchez-García, A Molina-Martín, MÁ Ariza-Gracia, DP Piñero
Eye & contact lens 49 (2), 77-82, 2023
12023
Computational planning tools in ophthalmology: Intrastromal corneal ring surgery
J Flecha-Lescún, MÁ Ariza Gracia, B Calvo Calzada
Ph. D. Thesis, 2021
12021
Biomechanically-driven simulations of the MyoRing treatment in subjects with high myopia
MA Ariza-Gracia, J Flecha-Lescún, BC Calzada, P Büchler
Investigative Ophthalmology & Visual Science 61 (7), 4722-4722, 2020
12020
Fluid structure interaction of the non-contact tonometry test
MÁ Ariza-Gracia, W Wu, M Malve, B Calvo, JFR Matas
Modeling and Artificial Intelligence in Ophthalmology 2 (2), 75-79, 2018
12018
Derzeitiger Stand der elektronischen „kontinuierlichen “Augendruckmessung
C Faschinger
Klinische Monatsblätter für Augenheilkunde 235 (02), 180-190, 2018
12018
The system can't perform the operation now. Try again later.
Articles 1–20