Follow
John Ginger
John Ginger
Research Director, Cyclone Testing Station, James Cook University
Verified email at jcu.edu.au - Homepage
Title
Cited by
Cited by
Year
Guidelines for converting between various wind averaging periods in tropical cyclone conditions
BA Harper, JD Kepert, JD Ginger
WMO, 2010
3872010
Net pressures on a low-rise full-scale building
JD Ginger, CW Letchford
Journal of Wind Engineering and Industrial Aerodynamics 83 (1-3), 239-250, 1999
951999
Internal pressures in a low-rise full-scale building
JD Ginger, KC Mehta, BB Yeatts
Journal of wind engineering and industrial aerodynamics 72, 163-174, 1997
941997
Variation of internal pressure with varying sizes of dominant openings and volumes
JD Ginger, JD Holmes, PY Kim
Journal of Structural Engineering 136 (10), 1319-1326, 2010
772010
Vulnerability model of an Australian high-set house subjected to cyclonic wind loading
DJ Henderson, JD Ginger
Wind and Structures 10 (3), 269-286, 2007
692007
Effect of building length on wind loads on low-rise buildings with a steep roof pitch
JD Ginger, JD Holmes
Journal of Wind Engineering and Industrial Aerodynamics 91 (11), 1377-1400, 2003
632003
Effect of building volume and opening size on fluctuating internal pressures
JD Ginger, JD Holmes, GA Kopp
Wind & structures 11 (5), 361-376, 2008
602008
Tropical Cyclone Larry: Estimation of wind field and assessment of building damage
JD Ginger, DJ Henderson, CJ Leitch, GN Boughton
Australian Journal of Structural Engineering 7 (3), 209-224, 2007
542007
Tropical Cyclone Larry–Damage to buildings in the Innisfail area
D Henderson, J Ginger, C Leitch, G Boughton, D Falck
Cyclone Testing Station. Townsville, James Cook University, 2006
542006
Characteristics of large pressures in regions of flow separation
JD Ginger, CW Letchford
Journal of Wind Engineering and Industrial Aerodynamics 49 (1-3), 301-310, 1993
541993
Response of pierced fixed corrugated steel roofing systems subjected to wind loads
DJ Henderson, JD Ginger
Engineering Structures 33 (12), 3290-3298, 2011
502011
Internal pressures–The dominant windward opening case–A review
JD Holmes, JD Ginger
Journal of Wind Engineering and Industrial Aerodynamics 100 (1), 70-76, 2012
492012
Planning, building and insuring: Adaptation of built environment to climate change induced increased intensity of natural hazards
DC King, J Ginger, S Williams, A Cottrell, Y Gurtner, C Leitch, ...
National Climate Change Adaptation Research Facility, 2013
472013
The gust wind speed duration in AS/NZS 1170.2
JD Holmes, JD Ginger
Australian Journal of Structural Engineering 13 (3), 207-217, 2012
462012
Internal pressures and cladding net wind loads on full-scale low-rise building
JD Ginger
Journal of structural engineering 126 (4), 538-543, 2000
462000
Wind loads on planar canopy roofs, part 2: fluctuating pressure distributions and correlations
JD Ginger, CW Letchford
Journal of Wind Engineering and Industrial Aerodynamics 51 (3), 353-370, 1994
431994
Gust durations, gust factors and gust response factors in wind codes and standards
JD Holmes, AC Allsop, JD Ginger
Wind and Structures 19 (3), 339-352, 2014
412014
Fragility and climate impact assessment of contemporary housing roof sheeting failure due to extreme wind
MG Stewart, JD Ginger, DJ Henderson, PC Ryan
Engineering Structures 171, 464-475, 2018
392018
Fragility analysis of roof damage to industrial buildings subject to extreme wind loading in non-cyclonic regions
MG Stewart, PC Ryan, DJ Henderson, JD Ginger
Engineering Structures 128, 333-343, 2016
362016
Wind loads on planar canopy roofs—Part 1: Mean pressure distributions
CW Letchford, JD Ginger
Journal of Wind Engineering and Industrial Aerodynamics 45 (1), 25-45, 1992
351992
The system can't perform the operation now. Try again later.