Follow
Abbas Rezaeian
Title
Cited by
Cited by
Year
Residual mechanical properties of polypropylene fiber-reinforced concrete after heating
J Eidan, I Rasoolan, A Rezaeian, D Poorveis
Construction and Building Materials 198, 195-206, 2019
1282019
Residual mechanical properties of high strength steel bolts subjected to heating-cooling cycle
V Kodur, M Yahyai, A Rezaeian, M Eslami, A Poormohamadi
Journal of Constructional Steel Research 131, 122-131, 2017
552017
Compressive stress-strain model and residual strength of self-compacting concrete containing recycled ceramic aggregate after exposure to fire
SMM Alizadeh, A Rezaeian, I Rasoolan, B Tahmouresi
Journal of Building Engineering 38, 102206, 2021
342021
Mechanical properties of steel welds at elevated temperatures
A Rezaeian, M Keshavarz, E Hajjari
Journal of constructional steel research 167, 105853, 2020
262020
Residual mechanical properties of high-strength steel bolts after exposure to elevated temperature
M Yahyai, V Kodur, A Rezaeian
Journal of Materials in Civil Engineering 30 (10), 04018240, 2018
232018
Behavior of beams in bolted column‐tree frames at elevated temperature
M Yahyai, A Rezaeian
Fire and Materials 40 (3), 482-497, 2016
172016
Fire response of steel column-tree moment resisting frames
A Rezaeian, M Yahyai
Materials and Structures 48, 1771-1784, 2015
162015
Behavior of steel column-trees under fire conditions
M Eslami, A Rezaeian, V Kodur
Journal of Structural Engineering 144 (9), 04018135, 2018
152018
Effect of temperature on mechanical properties of steel bolts
A Rezaeian, M Shafiei, M Eskandari
Journal of Materials in Civil Engineering 32 (9), 04020239, 2020
92020
Experimental cyclic performance of steel shear walls with single rectangular opening
G Kordzangeneh, H Showkati, A Rezaeian, M Yekrangnia
The Structural Design of Tall and Special Buildings 30 (2), e1821, 2021
82021
Post-fire mechanical properties of high strength grade 8.8 steel bolts
M Yahyai, A Rezaeian, V Kodur, M Eslami, A Poormohamadi
Proc., 9th Int. Conf. on Structures in Fire, 460-467, 2016
72016
Fire response of steel beams with bolted flange plate connections
M Ebrahimzadeh, A Rezaeian
Fire Technology 58 (1), 479-501, 2022
42022
Response of steel box columns in fire conditions
M Yahyai, A Rezaeian, M Safaeian
Journal of Structural and Construction Engineering 4 (1), 101-112, 2017
42017
Fire response of steel column trees with end-plate connections
A Rezaeian, S Eghbali
Journal of Structural Engineering 147 (10), 04021162, 2021
32021
Predicting extreme water surface elevation in tidal river reaches by different joint probability methods
A Adib, M Vaghefi, M Labibzadeh, A Rezaeian, A Tagavifar, H Foladfar
J. Food Agric. Environ 8, 988-991, 2010
32010
Effect of polypropylene short fibers on energy absorption capacity and durability of concrete
J Eidan, I Rasoolan, D Poorveis, A Rezaeian
Journal of Testing and Evaluation 49 (5), 3885-3898, 2021
22021
Behavior of Polypropylene Fiber-Reinforced Concrete Beams in Fire
A Rezaeian, A Daghari, V Kodur
ACI Materials Journal 119 (5), 25-35, 2022
12022
Experimental study on the effect of square opening size and location on cyclic response of steel plate shear walls
G Kordzangeneh, A Rezaeian, H Showkati, M Yekrangnia, ...
Structures 33, 4655-4669, 2021
12021
Performance of Link-To-Stub Bolted Connection in Column-Tree Moment Resisting Frames under Fire Conditions
M Yahyai, A REZAEIAN
JOURNAL OF STRUCTURAL AND CONSTRUCTION ENGINEERING 2 (3), 23-33, 2015
12015
Performance of steel beam with welded top-seat angle connections at elevated temperatures
A Rezaeian, M Mansoori, A Khajehdezfuly
Journal of Structural Fire Engineering 15 (1), 113-146, 2024
2024
The system can't perform the operation now. Try again later.
Articles 1–20