Follow
Georg Wieselthaler
Georg Wieselthaler
University of California, San Francisco
No verified email
Title
Cited by
Cited by
Year
Multicenter evaluation of an intrapericardial left ventricular assist system
M Strueber, G O’Driscoll, P Jansz, A Khaghani, WC Levy, ...
Journal of the American College of Cardiology 57 (12), 1375-1382, 2011
3022011
Clinical review: practical recommendations on the management of perioperative heart failure in cardiac surgery
A Mebazaa, AA Pitsis, A Rudiger, W Toller, D Longrois, SE Ricksten, ...
Critical care 14, 1-14, 2010
2742010
Mechanical circulatory support for advanced heart failure: effect of patient selection on outcome
MC Deng, M Loebe, A El-Banayosy, E Gronda, PGM Jansen, M Vigano, ...
Circulation 103 (2), 231-237, 2001
2442001
First clinical experience with the DeBakey VAD continuous-axial-flow pump for bridge to transplantation
GM Wieselthaler, H Schima, M Hiesmayr, R Pacher, G Laufer, GP Noon, ...
Circulation 101 (4), 356-359, 2000
2402000
Left ventricular assist devices decrease fixed pulmonary hypertension in cardiac transplant candidates
D Zimpfer, P Zrunek, W Roethy, M Czerny, H Schima, L Huber, M Grimm, ...
The Journal of thoracic and cardiovascular surgery 133 (3), 689-695, 2007
2092007
Renal function and outcome after continuous flow left ventricular assist device implantation
SE Sandner, D Zimpfer, P Zrunek, A Rajek, H Schima, D Dunkler, ...
The Annals of thoracic surgery 87 (4), 1072-1078, 2009
1992009
Initial clinical experience with a novel left ventricular assist device with a magnetically levitated rotor in a multi-institutional trial
GM Wieselthaler, O Gerry, P Jansz, A Khaghani, M Strueber, ...
The Journal of heart and lung transplantation 29 (11), 1218-1225, 2010
1932010
Suction events during left ventricular support and ventricular arrhythmias
M Vollkron, P Voitl, J Ta, G Wieselthaler, H Schima
The Journal of heart and lung transplantation 26 (8), 819-825, 2007
1692007
Evaluation of a lateral thoracotomy implant approach for a centrifugal-flow left ventricular assist device: the LATERAL clinical trial
E McGee Jr, M Danter, M Strueber, C Mahr, NA Mokadam, G Wieselthaler, ...
The Journal of Heart and Lung Transplantation 38 (4), 344-351, 2019
1622019
An ISHLT consensus document for prevention and management strategies for mechanical circulatory support infection
S Kusne, M Mooney, L Danziger-Isakov, A Kaan, LH Lund, H Lyster, ...
The Journal of Heart and Lung Transplantation 36 (10), 1137-1153, 2017
1612017
European experience of DuraHeart™ magnetically levitated centrifugal left ventricular assist system
M Morshuis, A El-Banayosy, L Arusoglu, R Koerfer, R Hetzer, ...
European Journal of Cardio-Thoracic Surgery 35 (6), 1020-1028, 2009
1602009
Platelet dysfunction in outpatients with left ventricular assist devices
B Steinlechner, M Dworschak, B Birkenberg, M Duris, P Zeidler, H Fischer, ...
The Annals of thoracic surgery 87 (1), 131-137, 2009
1472009
Development of a suction detection system for axial blood pumps
M Vollkron, H Schima, L Huber, R Benkowski, G Morello, G Wieselthaler
Artificial organs 28 (8), 709-716, 2004
1222004
Extracorporeal membrane oxygenation is superior to right ventricular assist device for acute right ventricular failure after heart transplantation
S Taghavi, A Zuckermann, J Ankersmit, G Wieselthaler, A Rajek, G Laufer, ...
The Annals of thoracic surgery 78 (5), 1644-1649, 2004
1182004
Interaction of the cardiovascular system with an implanted rotary assist device: simulation study with a refined computer model
M Vollkron, H Schima, L Huber, G Wieselthaler
Artificial organs 26 (4), 349-359, 2002
1162002
Results of the post-market registry to evaluate the HeartWare left ventricular assist system (ReVOLVE)
M Strueber, R Larbalestier, P Jansz, D Zimpfer, AE Fiane, S Tsui, A Simon, ...
The Journal of Heart and Lung Transplantation 33 (5), 486-491, 2014
1152014
Post-transplant survival after lowering fixed pulmonary hypertension using left ventricular assist devices
D Zimpfer, P Zrunek, S Sandner, H Schima, M Grimm, A Zuckermann, ...
European Journal of Cardio-Thoracic Surgery 31 (4), 698-702, 2007
1152007
Development of a reliable automatic speed control system for rotary blood pumps
M Vollkron, H Schima, L Huber, R Benkowski, G Morello, G Wieselthaler
The journal of heart and lung transplantation 24 (11), 1878-1885, 2005
1072005
Mechanical circulatory support as a bridge to heart transplantation: what remains? Long-term emotional sequelae in patients and spouses
B Bunzel, K Laederach-Hofmann, G Wieselthaler, W Roethy, E Wolner
The Journal of heart and lung transplantation 26 (4), 384-389, 2007
1002007
Noninvasive monitoring of rotary blood pumps: Necessity, possibilities, and limitations
H Schima, W Trubel, A Moritz, G Wieselthaler, HG Stohr, H Thoma, ...
Artificial Organs 16 (2), 195-202, 1992
1001992
The system can't perform the operation now. Try again later.
Articles 1–20