An implantable analyzer of bio-impedance dynamics: Mixed signal approach M Min, T Parve, V Kukk, A Kuhlberg IMTC 2001. Proceedings of the 18th IEEE Instrumentation and Measurement …, 2001 | 72 | 2001 |
Impact of cracks to the hygrothermal properties of CLT water vapour resistance and air permeability V Kukk, R Horta, M Püssa, G Luciani, H Kallakas, T Kalamees, J Kers Energy Procedia 132, 741-746, 2017 | 27 | 2017 |
Designing highly insulated cross-laminated timber external walls in terms of hygrothermal performance: Field measurements and simulations V Kukk, L Kaljula, J Kers, T Kalamees Building and Environment 212, 108805, 2022 | 24 | 2022 |
Airtightness of cross-laminated timber envelopes: Influence of moisture content, indoor humidity, orientation, and assembly V Kukk, A Bella, J Kers, T Kalamees Journal of Building Engineering 44, 102610, 2021 | 20 | 2021 |
Decomposition method of an electrical bio-impedance signal into cardiac and respiratory components A Krivoshei, V Kukk, M Min Physiological measurement 29 (6), S15, 2008 | 19 | 2008 |
Integrating labs into learning environment M Jaanus, V Kukk, K Umbleja Elektronika ir Elektrotechnika 102 (6), 27-30, 2010 | 15 | 2010 |
The effects of production technologies on the air permeability and crack development of cross-laminated timber V Kukk, T Kalamees, J Kers Journal of Building Physics 43 (3), 171-186, 2019 | 14 | 2019 |
A case study on the construction of a CLT building without a preliminary roof E Liisma, BL Kuus, V Kukk, T Kalamees Journal of Sustainable Architecture and Civil Engineering 25 (2), 53-62, 2019 | 13 | 2019 |
Influence of interior layer properties to moisture dry-out of CLT walls V Kukk, A Külaots, J Kers, T Kalamees Canadian Journal of Civil Engineering 46 (11), 1001-1009, 2019 | 13 | 2019 |
Improved C5D electronic realization of conductivity detector for capillary electrophoresis M Jaanus, A Udal, V Kukk, K Umbleja, J Gorbatsova, L Molder Elektronika ir elektrotechnika 22 (3), 29-32, 2016 | 13 | 2016 |
Wetting circumstances, expected moisture content, and drying performance of CLT end-grain edges based on field measurements and laboratory analysis K Kalbe, T Kalamees, V Kukk, A Ruus, A Annuk Building and Environment 221, 109245, 2022 | 12 | 2022 |
Identification and improvement of critical joints in CLT construction without weather protection K Kalbe, V Kukk, T Kalamees E3S Web of Conferences 172, 10002, 2020 | 12 | 2020 |
New concepts of automatic answer evaluation in competence based learning K Umbleja, V Kukk, M Jaanus, A Udal 2014 IEEE Global Engineering Education Conference (EDUCON), 922-925, 2014 | 10 | 2014 |
Using microcontrollers for high accuracy analogue measurements M Jaanus, A Udal, V Kukk, K Umbleja Elektronika ir Elektrotechnika 19 (6), 51-54, 2013 | 10 | 2013 |
Impact of built-in moisture on the design of hygrothermally safe cross-laminated timber external walls: A stochastic approach V Kukk, J Kers, T Kalamees, L Wang, H Ge Building and Environment 226, 109736, 2022 | 9 | 2022 |
Competence-based approach to learning K Umbleja, V Kukk, M Jaanus 2013 IEEE Global Engineering Education Conference (EDUCON), 552-559, 2013 | 9 | 2013 |
An adaptively tunable model of the cardiac signal for the bio-impedance signal decomposer (BISD) A Krivoshei, V Kukk, M Min 2008 IEEE International Workshop on Medical Measurements and Applications, 49-52, 2008 | 9 | 2008 |
Home lab kits for introductory course in electrical engineering M Jaanus, N Hein, V Kukk, A Sullin EUROCON 2007-The International Conference on" Computer as a Tool", 2676-2679, 2007 | 9 | 2007 |
Signal-shape locked loop (SSLL) as an adaptive separator of cardiac and respiratory components of bio-impedance signal A Krivoshei, M Min, V Kukk 2007 IEEE International Workshop on Medical Measurement and Applications, 1-6, 2007 | 9 | 2007 |
Field measurements and simulation of an massive wood panel envelope with ETICS V Kukk, J Kers, T Kalamees Wood Material Science & Engineering 16 (1), 27-34, 2021 | 7 | 2021 |