Mode domain multiphase transmission line model-use in transient studies MC Tavares, J Pissolato, CM Portela IEEE Transactions on Power Delivery 14 (4), 1533-1544, 1999 | 101 | 1999 |
Six-phase transmission line-propagation characteristics and new three-phase representation CM Portela, MC Tavares IEEE Transactions on Power Delivery 8 (3), 1470-1483, 1993 | 85 | 1993 |
Half-wave length line energization case test-proposition of a real test MC Tavares, CM Portela 2008 International Conference on High Voltage Engineering and Application …, 2008 | 81 | 2008 |
Transmission system parameters optimization-sensitivity analysis of secondary arc current and recovery voltage MC Tavares, CM Portela IEEE Transactions on Power Delivery 19 (3), 1464-1471, 2004 | 66 | 2004 |
Behavior of overhead transmission line parameters on the presence of ground wires S Kurokawa, MC Tavares, CM Portela, AJ Prado IEEE transactions on power delivery 20 (2), 1669-1676, 2005 | 62 | 2005 |
A new procedure to derive transmission-line parameters: Applications and restrictions S Kurokawa, J Pissolato, MC Tavares, CM Portela, AJ Prado IEEE transactions on power delivery 21 (1), 492-498, 2005 | 58 | 2005 |
Earth conductivity and permittivity data measurements: Influence in transmission line transient performance CM Portela, JB Gertrudes, MC Tavares, J Pissolato Electric power systems research 76 (11), 907-915, 2006 | 56 | 2006 |
Implementation and performance evaluation of a reclosing method for shunt reactor-compensated transmission lines P Mestas, MC Tavares, AM Gole IEEE Transactions on Power Delivery 26 (2), 954-962, 2010 | 55 | 2010 |
Modeling, simulation and optimization of transmission lines. Applicability and limitations of some used procedures C Portela, MC Tavares IEEE Transmission and Distribution Latin America, 38, 2002 | 55 | 2002 |
Faulted phase selection for half-wavelength power transmission lines RGF Espinoza, MC Tavares IEEE Transactions on Power Delivery 33 (2), 992-1001, 2017 | 45 | 2017 |
Accurate representation of soil behaviour for transient studies CM Portela, MC Tavares, J Pissolato Filho IEE Proceedings-Generation, Transmission and Distribution 150 (6), 736-744, 2003 | 44 | 2003 |
Comparison between traditional single‐phase auto reclosing and adaptive technique based on harmonic content measurement O Dias, MC Tavares IET Generation, Transmission & Distribution 11 (4), 905-914, 2017 | 43 | 2017 |
Comparison of secondary arcs for reclosing applications O Dias, F Magrin, MC Tavares IEEE Transactions on Dielectrics and Electrical Insulation 24 (3), 1592-1599, 2017 | 40 | 2017 |
Methodology for optimizing the capacity and costs of overhead transmission lines by modifying their bundle geometry JS Acosta, MC Tavares Electric Power Systems Research 163, 668-677, 2018 | 39 | 2018 |
Quasi-modes multiphase transmission line model MC Tavares, J Pissolato Filho, CM Portela Electric Power Systems Research 49 (3), 159-167, 1999 | 35 | 1999 |
Adaptative single-phase autoreclosing based on secondary arc voltage harmonic signature AA Montanari, MC Tavares, CM Portela parameters 6, 7, 2009 | 30 | 2009 |
Transient analysis concerning capacitor bank switching in a distribution system DV Coury, CJ Dos Santos, M Oleskovicz, MC Tavares Electric Power Systems Research 65 (1), 13-21, 2003 | 30 | 2003 |
Modeling a power transformer for investigation of digital protection schemes DV Coury, PG Campos, MC Tavares 8th International Conference on Harmonics and Quality of Power. Proceedings …, 1998 | 30 | 1998 |
Technical and economic comparison between direct current and half‐wavelength transmission systems for very long distances G Samorodov, S Kandakov, S Zilberman, T Krasilnikova, MC Tavares, ... IET Generation, Transmission & Distribution 11 (11), 2871-2878, 2017 | 29 | 2017 |
Voltage harmonic content of long artificially generated electrical arc in out-door experiment at 500 kV towers MC Tavares, J Talaisys, A Camara IEEE Transactions on Dielectrics and Electrical Insulation 21 (3), 1005-1014, 2014 | 29 | 2014 |