Follow
Seung Jun Yeo
Seung Jun Yeo
Verified email at khu.ac.kr
Title
Cited by
Cited by
Year
Carbon nanotube field emitters synthesized on metal alloy substrate by PECVD for customized compact field emission devices to be used in X-ray source applications
S Park, AP Gupta, SJ Yeo, J Jung, SH Paik, M Mativenga, SH Kim, ...
Nanomaterials 8 (6), 378, 2018
582018
Direct synthesis of carbon nanotube field emitters on metal substrate for open-type X-ray source in medical imaging
AP Gupta, S Park, SJ Yeo, J Jung, C Cho, SH Paik, H Park, YC Cho, ...
Materials 10 (8), 878, 2017
472017
Design and Fabrication of CNT-Based -Gun Using Stripe-Patterned Alloy Substrate for X-Ray Applications
J Lim, AP Gupta, SJ Yeo, M Kong, CG Cho, SH Kim, JS Ahn, M Mativenga, ...
IEEE Transactions on Electron Devices 66 (12), 5301-5304, 2019
212019
Study on the size of fullerene (C60) aggregates in solution by photoluminescence and HRTEM measurements
SJ Yeo, R Pode, JS Ahn, HM Kim
J. Korean Phys. Soc 55 (1), 322, 2009
102009
Compact X-ray tube with ceramic vacuum seal for portable and robust dental imaging
AP Gupta, J Choi, M Mativenga, K Park, J Jang, SJ Yeo, J Jung, MS Chae, ...
IEEE Transactions on Electron Devices 68 (9), 4705-4710, 2021
82021
A feasibility study of a portable intraoperative specimen imaging X‐ray system based on carbon nanotube field emitters
AP Gupta, SJ Yeo, M Mativenga, J Jung, W Kim, J Lim, J Park, JS Ahn, ...
International Journal of Imaging Systems and Technology 31 (3), 1128-1135, 2021
72021
Development of 120 kV CNT-based digital x-ray tube for fluoroscopy
AP Gupta, J Jang, K Park, H Lee, D Seo, MB Sharma, J Jung, YK Park, ...
Medical Imaging 2022: Physics of Medical Imaging 12031, 1073-1080, 2022
52022
Hydrophobic properties of polytetrafluoroethylene thin films fabricated at various catalyzer temperatures through catalytic chemical vapor deposition using a tungsten catalyzer
JO Cha, SJ Yeo, R Pode, JS Ahn
Journal of Nanoscience and Nanotechnology 11 (7), 5829-5833, 2011
42011
Stationary multi x-ray source system with carbon nanotube emitters for digital tomosynthesis
J Park, AP Gupta, W Kim, J Lim, S Yeo, D Kim, C Jeong, KH Yoon, S Cho, ...
Medical Imaging 2021: Physics of Medical Imaging 11595, 882-887, 2021
32021
X-ray tube based on carbon nanotube field emitter for low dose mini C-arm fluoroscopy
J Lim, AP Gupta, H Park, J Choi, J Jung, J Jang, SJ Yeo, JS Ahn, BN Lee, ...
Medical Imaging 2021: Physics of Medical Imaging 11595, 836-841, 2021
22021
Breast imaging using micro-resolution field emission x-ray system with carbon nanotube emitter
SJ Yeo, AP Gupta, J Jung, JS Ahn, H Park, S Paik, SH Kim, NG Kim, B Ko, ...
Medical Imaging 2018: Physics of Medical Imaging 10573, 1414-1419, 2018
22018
A glass-sealed field emission x-ray tube based on carbon nanotube emitter for medical imaging
SJ Yeo, J Jeong, JS Ahn, H Park, J Kwak, E Noh, S Paik, SH Kim, J Ryu
Medical Imaging 2016: Physics of Medical Imaging 9783, 1351-1357, 2016
22016
Photoluminescence of nano-scal fullerene (C60) aggregates in a solvent mixture
SJ Yeo, JO Cha, R Pode, JS Ahn, HM Kim, BR Rhee
Journal of the Korean Physical Society 53 (5 PART 1), 7-2681, 2008
22008
Geometric comparison of chest tomosynthesis system with thermionic filament and carbon nanotube field emitter-based x-ray sources
J Choi, J Yu, H Lee, AP Gupta, MB Sharma, J Jang, J Jung, WJ Lee, ...
Medical Imaging 2023: Physics of Medical Imaging 12463, 937-943, 2023
12023
A portable x-ray source based on CNT for chest radiography
AP Gupta, J Jang, J Jung, SJ Yeo, JS Ahn, J Ryu
Medical Imaging 2023: Physics of Medical Imaging 12463, 930-936, 2023
12023
Operation of multi-beam compact tomosynthesis system using carbon nanotube emitters
J Choi, H Lee, AP Gupta, MB Sharma, J Jang, J Jung, WJ Lee, SJ Yeo, ...
Medical Imaging 2023: Physics of Medical Imaging 12463, 944-949, 2023
12023
A comparison of digital-based CNT and analogue-based filament x-ray source in regard to intraoperative specimen x-ray system’s development
AP Gupta, T Kim, MB Sharma, J Choi, J Jang, SJ Yeo, J Jung, JS Ahn, ...
Medical Imaging 2023: Physics of Medical Imaging 12463, 923-929, 2023
12023
Development of 120 kV ceramic x-ray tube for dental imaging and its comparison with commercial glass x-ray tube
J Jang, AP Gupta, K Park, J Choi, H Lee, MB Sharma, D Seo, J Jung, ...
Medical Imaging 2022: Physics of Medical Imaging 12031, 1127-1132, 2022
12022
Effect of self-focusing gate structure length in CNT-based E-gun for intraoperative specimen radiographic system
AP Gupta, J Choi, J Jang, D Seo, MB Sharma, SJ Yeo, J Jung, JS Ahn, ...
Medical Imaging 2022: Physics of Medical Imaging 12031, 1142-1149, 2022
12022
Characterization of compact alumina vacuum sealed x-ray tube for medical imaging: interpretation with simulation program
J Choi, AP Gupta, J Jang, SJ Yeo, J Jung, MS Chae, YH Yeon, BN Lee, ...
Medical Imaging 2021: Physics of Medical Imaging 11595, 848-854, 2021
12021
The system can't perform the operation now. Try again later.
Articles 1–20