Follow
César Queral
César Queral
profesor de ingenieria nuclear, universidad politecnica de madrid
Verified email at upm.es
Title
Cited by
Cited by
Year
AP1000® Large-Break LOCA BEPU analysis with TRACE code
C Queral, J Montero-Mayorga, J Gonzalez-Cadelo, G Jimenez
Annals of Nuclear Energy 85, 576-589, 2015
682015
SCAIS (Simulation Code System for Integrated Safety Assessment): Current status and applications
JM Izquierdo, J Hortal, M Sánchez, E Melendez, R Herrero, J Gil, L Gamo, ...
Safety, Reliability and Risk Analysis, 159-166, 2008
472008
Application of the integrated safety assessment methodology to safety margins. Dynamic event trees, damage domains and risk assessment
L Ibánez, J Hortal, C Queral, J Gómez-Magán, M Sánchez-Perea, ...
Reliability Engineering & System Safety 147, 170-193, 2016
382016
AP1000® SBLOCA simulations with TRACE code
J Montero-Mayorga, C Queral, J Gonzalez-Cadelo
Annals of Nuclear Energy 75, 87-100, 2015
362015
Accident Management actions in an upper-head Small-Break Loss-Of-Coolant accident with high-pressure safety injection failed
C Queral, J González-Cadelo, G Jimenez, E Villalba
Nuclear Technology 175 (3), 572-593, 2011
282011
Dynamic event trees without success criteria for full spectrum LOCA sequences applying the integrated safety assessment (ISA) methodology
C Queral, J Gómez-Magán, C París, J Rivas-Lewicky, M Sánchez-Perea, ...
Reliability Engineering & System Safety 171, 152-168, 2018
272018
Uncertainty and sensitivity analysis of a PWR LOCA sequence using parametric and non-parametric methods
E Zugazagoitia, C Queral, K Fernández-Cosials, J Gómez, LF Durán, ...
Reliability Engineering & System Safety 193, 106607, 2020
242020
Quantitative risk reduction by means of recovery strategies
C París, C Queral, J Mula, J Gómez-Magán, M Sánchez-Perea, ...
Reliability Engineering & System Safety 182, 13-32, 2019
242019
Analysis of cold leg LOCA with failed HPSI by means of integrated safety assessment methodology
J Gonzalez-Cadelo, C Queral, J Montero-Mayorga
Annals of Nuclear Energy 69, 144-167, 2014
242014
Analysis of the operator action and the single failure criteria in a SGTR sequence using best estimate assumptions with TRACE 5.0
G Jimenez, C Queral, MJ Rebollo-Mena, JC Martínez-Murillo, ...
Annals of Nuclear Energy 58, 161-177, 2013
242013
Verification of SAMGs in SBO sequences with Seal LOCA. Multiple damage domains
C Queral, L Mena-Rosell, G Jimenez, M Sanchez-Perea, J Gomez-Magan, ...
Annals of Nuclear Energy 98, 90-111, 2016
232016
BWR Mark III containment analyses using a GOTHIC 8.0 3D model
G Jimenez, C Serrano, E Lopez-Alonso, M del Carmen Molina, D Calvo, ...
Annals of Nuclear Energy 85, 687-703, 2015
232015
Effects of delayed RCP trip during SBLOCA in PWR
J Montero-Mayorga, C Queral, J Gonzalez-Cadelo
Annals of Nuclear Energy 63, 107-125, 2014
232014
Application of Expanded Event Trees combined with uncertainty analysis methodologies
C Queral, K Fernández-Cosials, E Zugazagoitia, C Paris, J Magan, ...
Reliability Engineering & System Safety 205, 107246, 2021
202021
Analysis of the equipment and instrumentation qualification criteria using 3D containment models
G Jimenez, MK Fernández-Cosials, R Bocanegra, C Queral
Nuclear Engineering and Design 323, 28-38, 2017
192017
A code for simulation of human failure events in nuclear power plants: SIMPROC
J Gil, I Fernández, S Murcia, J Gomez, H Marrão, C Queral, A Expósito, ...
Nuclear Engineering and Design 241 (4), 1097-1107, 2011
192011
The H2020 McSAFER project: main goals, technical work program, and status
VH Sanchez-Espinoza, S Gabriel, H Suikkanen, J Telkkä, V Valtavirta, ...
Energies 14 (19), 6348, 2021
172021
Three-dimensional simulation of a LBLOCA in an AP1000® containment building
K Fernández-Cosials, Z Goñi, G Jiménez, C Queral, J Montero
Energy Procedia 127, 234-241, 2017
172017
Analysis of primary bleed and feed strategies for selected SBLOCA sequences in a German Konvoi PWR using ASTEC V2. 0
I Gómez-García-Toraño, VH Sánchez-Espinoza, R Stieglitz, C Queral
Annals of Nuclear Energy 110, 818-832, 2017
162017
Evaluation of the offsite dose contribution to the global risk in a Steam Generator Tube Rupture scenario
MJ Rebollo, C Queral, G Jimenez, J Gómez-Magán, E Meléndez, ...
Reliability Engineering & System Safety 147, 32-48, 2016
162016
The system can't perform the operation now. Try again later.
Articles 1–20