SIMAP: Intelligent System for Predictive Maintenance: Application to the health condition monitoring of a windturbine gearbox
MC Garcia, MA Sanz-Bobi, J Del Pico
Computers in industry 57 (6), 552-568, 2006
4422006
State of the art of thermoelectric generators based on heat recovered from the exhaust gases of automobiles
J Vázquez, MA Sanz-Bobi, R Palacios, A Arenas
Proc. 7th European workshop on thermoelectrics, 2002
2192002
Food Track & Trace ontology for helping the food traceability control
T Pizzuti, G Mirabelli, MA Sanz-Bobi, F Goméz-Gonzaléz
Journal of Food Engineering 120, 17-30, 2014
1262014
General asset management model in the context of an electric utility: Application to power transformers
JL Velasquez-Contreras, MA Sanz-Bobi, SG Arellano
Electric Power Systems Research 81 (11), 2015-2037, 2011
742011
Ontology matching system for future energy smart grids
R Santodomingo, S Rohjans, M Uslar, JA Rodríguez-Mondéjar, ...
Engineering Applications of Artificial Intelligence 32, 242-257, 2014
622014
Ontology matching approach to the harmonization of CIM and IEC 61850 standards
R Santodomingo, JA Rodríguez-Mondéjar, MA Sanz-Bobi
2010 First IEEE International Conference on Smart Grid Communications, 55-60, 2010
622010
System for detection of abnormalities and fraud in customer consumption
JR Galvan, A Elices, A Muñoz, T Czernichow, MA Sanz-Bobi
Proc. of the 12th Conference on the Electric Power Supply Industry, 1998
491998
Profit-maximization generation maintenance scheduling through bi-level programming
P Mazidi, Y Tohidi, A Ramos, MA Sanz-Bobi
European journal of operational research 264 (3), 1045-1057, 2018
462018
Failure risk indicators for a maintenance model based on observable life of industrial components with an application to wind turbines
RJ de Andrade Vieira, MA Sanz-Bobi
IEEE Transactions on Reliability 62 (3), 569-582, 2013
452013
DADICC: Intelligent system for anomaly detection in a combined cycle gas turbine plant
A Arranz, A Cruz, MA Sanz-Bobi, P Ruíz, J Coutiño
Expert Systems with Applications 34 (4), 2267-2277, 2008
452008
A cumulative pollution index for the estimation of the leakage current on insulator strings
H de Santos, MÁ Sanz-Bobi
IEEE Transactions on Power Delivery 35 (5), 2438-2446, 2020
412020
An incipient fault detection system based on the probabilistic radial basis function network: Application to the diagnosis of the condenser of a coal power plant
A Muñoz, MA Sanz-Bobi
Neurocomputing 23 (1-3), 177-194, 1998
401998
Diamond: distributed multi-agent architecture for monitoring and diagnosis
H Wörn, T Längle, M Albert, A Kazi, A Brighenti, SR Seijo, C Senior, ...
Production planning & control 15 (2), 189-200, 2004
372004
Wind turbine prognostics and maintenance management based on a hybrid approach of neural networks and a proportional hazards model
P Mazidi, L Bertling Tjernberg, MA Sanz Bobi
Proceedings of the Institution of Mechanical Engineers, Part O: Journal of …, 2017
342017
Research on the pollution performance and degradation of superhydrophobic nano-coatings for toughened glass insulators
H de Santos, MÁ Sanz-Bobi
Electric Power Systems Research 191, 106863, 2021
322021
Facilitating the automatic mapping of IEC 61850 signals and CIM measurements
R Santodomingo, S Rohjans, M Uslar, JA Rodríguez-Mondèjar, ...
IEEE Transactions on Power Systems 28 (4), 4348-4355, 2013
322013
Auto-regressive processes explained by self-organized maps. Application to the detection of abnormal behavior in industrial processes
C Brighenti, MÁ Sanz-Bobi
IEEE transactions on neural networks 22 (12), 2078-2090, 2011
322011
Optimising a microgrid system by deep reinforcement learning techniques
D Domínguez-Barbero, J García-González, MA Sanz-Bobi, ...
Energies 13 (11), 2830, 2020
312020
Using semantic web resources to translate existing files between CIM and IEC 61850
R Santodomingo, JA Rodriguez-Mondejar, MA Sanz-Bobi
IEEE Transactions on Power Systems 27 (4), 2047-2054, 2012
312012
Experiences learned from the on-line internal monitoring of the behaviour of a transformer
MA Sanz-Bobi, A Garcia-Cerrada, R Palacios, J Villar, J Rolan, B Moran
1997 IEEE International Electric Machines and Drives Conference Record, TC3 …, 1997
301997