Follow
eduardo garcia breijo
eduardo garcia breijo
Professor of electronic engineering, Universitat Politècnica de València
Verified email at eln.upv.es
Title
Cited by
Cited by
Year
Compilador C CCS y simulador PROTEUS para microcontroladores PIC
EG Breijo
Marcombo, 2012
2812012
An “electronic tongue” design for the qualitative analysis of natural waters
R Martınez-Máñez, J Soto, E Garcia-Breijo, L Gil, J Ibáñez, E Llobet
Sensors and Actuators B: Chemical 104 (2), 302-307, 2005
1732005
A multisensor in thick-film technology for water quality control
R Martínez-Máñez, J Soto, E García-Breijo, L Gil, J Ibáñez, E Gadea
Sensors and Actuators A: Physical 120 (2), 589-595, 2005
1222005
Freshness monitoring of sea bream (Sparus aurata) with a potentiometric sensor
JM Barat, L Gil, E García-Breijo, MC Aristoy, F Toldrá, R Martínez-Máñez, ...
Food chemistry 108 (2), 681-688, 2008
1182008
Monitoring of physical–chemical and microbiological changes in fresh pork meat under cold storage by means of a potentiometric electronic tongue
L Gil, JM Barat, D Baigts, R Martínez-Máñez, J Soto, E Garcia-Breijo, ...
Food Chemistry 126 (3), 1261-1268, 2011
1132011
Fish freshness analysis using metallic potentiometric electrodes
L Gil, JM Barat, E Garcia-Breijo, J Ibañez, R Martínez-Máñez, J Soto, ...
Sensors and Actuators B: Chemical 131 (2), 362-370, 2008
1052008
An electronic tongue for fish freshness analysis using a thick-film array of electrodes
L Gil, JM Barat, I Escriche, E Garcia-Breijo, R Martínez-Máñez, J Soto
Microchimica Acta 163, 121-129, 2008
1042008
A novel humid electronic nose combined with an electronic tongue for assessing deterioration of wine
L Gil-Sánchez, J Soto, R Martínez-Máñez, E Garcia-Breijo, J Ibáñez, ...
Sensors and Actuators A: Physical 171 (2), 152-158, 2011
922011
Accurate concentration determination of anions nitrate, nitrite and chloride in minced meat using a voltammetric electronic tongue
I Campos, R Masot, M Alcaniz, L Gil, J Soto, JL Vivancos, E García-Breijo, ...
Sensors and Actuators B: Chemical 149 (1), 71-78, 2010
882010
Prediction of NaCl, nitrate and nitrite contents in minced meat by using a voltammetric electronic tongue and an impedimetric sensor
RH Labrador, R Masot, M Alcañiz, D Baigts, J Soto, R Martínez-Mañez, ...
Food Chemistry 122 (3), 864-870, 2010
862010
New potentiomentric dissolved oxygen sensors in thick film technology
R Martı́nez-Máñez, J Soto, J Lizondo-Sabater, E Garcı́a-Breijo, L Gil, ...
Sensors and Actuators B: Chemical 101 (3), 295-301, 2004
602004
Ditopic N-Crowned 4-(p-Aminophenyl)-2,6-diphenylpyridines:  Implications of Macrocycle Topology on the Spectroscopic Properties, Cation Complexation, and …
B García-Acosta, R Martínez-Máñez, F Sancenón, J Soto, K Rurack, ...
Inorganic chemistry 46 (8), 3123-3135, 2007
572007
A comparison study of pattern recognition algorithms implemented on a microcontroller for use in an electronic tongue for monitoring drinking waters
E Garcia-Breijo, J Atkinson, L Gil-Sanchez, R Masot, J Ibañez, J Garrigues, ...
Sensors and Actuators A: Physical 172 (2), 570-582, 2011
552011
Characterization of embeddable potentiometric thick-film sensors for monitoring chloride penetration in concrete
JM Gandía-Romero, R Bataller, P Monzón, I Campos, E García-Breijo, ...
Sensors and Actuators B: Chemical 222, 407-418, 2016
532016
Multi‐Channel Receptors and Their Relation to Guest Chemosensing and Reconfigurable Molecular Logic Gates
D Jiménez, R Martínez‐Máñez, F Sancenón, JV Ros‐Lis, J Soto, Á Benito, ...
European journal of inorganic chemistry 2005 (12), 2393-2403, 2005
492005
Low-cost capacitive humidity sensor for application within flexible RFID labels based on microcontroller systems
J Pelegrí-Sebastiá, E García-Breijo, J Ibanez, T Sogorb, N Laguarda-Miro, ...
IEEE Transactions on Instrumentation and Measurement 61 (2), 545-553, 2011
482011
Performance of miniaturised thick-film solid state pH sensors
M Glanc-Gostkiewicz, M Sophocleous, JK Atkinson, E Garcia-Breijo
Sensors and Actuators A: Physical 202, 2-7, 2013
472013
The effect on performance of fabrication parameter variations of thick-film screen printed silver/silver chloride potentiometric reference electrodes
M Glanc, M Sophocleous, JK Atkinson, E Garcia-Breijo
Sensors and Actuators A: Physical 197, 1-8, 2013
442013
TNT detection using a voltammetric electronic tongue based on neural networks
EG Breijo, CO Pinatti, RM Peris, MA Fillol, R Martínez-Máñez, JS Camino
Sensors and Actuators A: Physical 192, 1-8, 2013
412013
Thick film screen printed environmental and chemical sensor array reference electrodes suitable for subterranean and subaqueous deployments
JK Atkinson, M Glanc, M Prakorbjanya, M Sophocleous, RP Sion, ...
Microelectronics International 30 (2), 92-98, 2013
392013
The system can't perform the operation now. Try again later.
Articles 1–20