Follow
J. Vercher
J. Vercher
Dpto. de Construcciones Arquitectónicas - Universitat Politècnica de València
Verified email at csa.upv.es
Title
Cited by
Cited by
Year
Pathology of building materials in historic buildings. Relationship between laboratory testing and infrared thermography
C Lerma, Á Mas, E Gil, J Vercher, MJ Peñalver
Materiales de Construcción 64 (313), 009, 2014
552014
Influence of fibre and matrix characteristics on properties and durability of wood–plastic composites in outdoor applications
J Vercher, V Fombuena, A Diaz, M Soriano
Journal of Thermoplastic Composite Materials 33 (4), 477-500, 2020
262020
Exposure Factors Influence Stone Deterioration by Crystallization of Soluble Salts
E Gil, Á Mas, C Lerma, J Vercher
Advances in Materials Science and Engineering 2015, 2015
192015
Quantitative Analysis Procedure for Building Materials in Historic Buildings by Applying Infrared Thermography
C Lerma, Á Mas, E Gil, J Vercher, ME Torner
Russian Journal of Nondestructive Testing 54 (8), 601-609, 2018
172018
Contribution of green roofs to energy savings in building renovations
JG Borràs, C Lerma, Á Mas, J Vercher, E Gil
Energy for Sustainable Development 71, 212-221, 2022
152022
Design and construction recommendations for brick enclosures with continuous air chamber
F Cubel, A Mas, J Vercher, E Gil
Construction and Building Materials 36, 151-164, 2012
152012
Non-destructive techniques methodologies for the detection of ancient structures under heritage buildings
E Gil, Á Mas, C Lerma, ME Torner, J Vercher
International Journal of Architectural Heritage 15 (10), 1457-1473, 2021
142021
Evaluation of hygrothermal behaviour in heritage buildings through sensors, CFD modelling and IRT
C Lerma, JG Borràs, Á Mas, ME Torner, J Vercher, E Gil
Sensors 21 (2), 566, 2021
142021
Diagnosis and intervention criteria in slabs damaged by severe corrosion of prestressed joists
J Vercher, E Gil, A Mas, C Lerma
Journal of Performance of Constructed Facilities 29 (1), 04014040, 2015
122015
Methodology for Thermal Behaviour Assessment of Homogeneous Façades in Heritage Buildings
E Gil, C Lerma, J Vercher, Á Mas
Journal of Sensors 2017, 2017
82017
Energy Efficiency Evaluation of Green Roofs as an Intervention Strategy in Residential Buildings in the Field of Spanish Climate
JG Borràs, C Lerma, Á Mas, J Vercher, E Gil
Buildings 12 (7), 959, 2022
72022
Hygrothermal Behaviour of Continuous Air Chambers on Stone Panels Façades through CFD and IRT
C Lerma, Á Mas, E Gil, J Vercher
Applied Sciences 9 (15), 3001, 2019
52019
Elastic-plastic formulation for concrete encased sections interaction diagram tracing
E Fenollosa, E Gil, I Cabrera, J Vercher
STEEL AND COMPOSITE STRUCTURES 19 (4), 861-876, 2015
52015
Seguridad remanente a flexión en forjados con corrosión en las viguetas
E Gil, J Vercher, A Mas, E Fenollosa
Informes de la Construcción 67 (537), e054, 2015
42015
Design and construction recommendations for connections arrangement in anchored veneers with continuous air cavity
MDLA Mas Tomas, JM Vercher Sanchis, FJ Cubel Arjona, E Gil Benso, ...
Revista de la Construcción (Online) 17 (1), 137-148, 2018
32018
Flexural Strengthening of Damaged T-Joists with Severe Corrosion Using CFRP Sheets
J Vercher, E Gil, Á Mas, C Lerma, ME Torner
Advances in Materials Science and Engineering 2017, 2017
32017
Analysis of the residual safety level in RC slabs with severe joist corrosion
J Vercher, E Gil, A Mas, F Cubel
Journal of Performance of Constructed Facilities 29 (4), 04014112, 2015
32015
Analysis of Energy Efficiency in Construction Solutions at the Façade-slab Connection
J Vercher, C Lerma, M Vidal, E Gil
Advanced Materials Research 787, 731-735, 2013
32013
Embedding of the Church of the Asunción of Llíria (Spain). Origin and Consequences
M Torner, Á Mas, C Lema, E Gil, J Vercher
Estoa. Revista de la Facultad de Arquitectura y Urbanismo de la Universidad …, 2019
22019
Analysis Method for Studying Groundwater under a Church
ME Torner, Á Mas, C Lerma, E Gil, J Vercher, J Padin, J Herráez
Applied Mechanics and Materials 861, 263-270, 2017
22017
The system can't perform the operation now. Try again later.
Articles 1–20