Follow
Adriana Gonzalez-Gago
Adriana Gonzalez-Gago
Verified email at uniovi.es
Title
Cited by
Cited by
Year
Optimizing GC-ICP-MS for ultra-trace quantification of PBDEs in natural water samples using species-specific isotope dilution
A González-Gago, D Pröfrock, A Prange
Journal of Analytical Atomic Spectrometry 30 (1), 180-190, 2015
272015
Determination of trihalomethanes in drinking water by GC-ICP-MS using compound independent calibration with internal standard
A González-Gago, JM Marchante-Gayón, JIG Alonso
Journal of Analytical Atomic Spectrometry 22 (9), 1138-1144, 2007
262007
Determination of the uncertainties in the theoretical mass isotopomer distribution of molecules
JIG Alonso, P Rodríguez-González, A González-Gago, ...
Analytica chimica acta 664 (1), 68-76, 2010
212010
Determination of ultra-trace levels of priority PBDEs in water samples by isotope dilution GC(ECNI)MS using 81Br-labelled standards
A González-Gago, SH Brandsma, PEG Leonards, J de Boer, ...
Analytical and Bioanalytical Chemistry 401, 2639-2649, 2011
182011
Synthesis of 81Br-Labeled Polybrominated Diphenyl Ethers and Their Characterization Using GC(EI)MS and GC(ICP)MS
A Gonzalez-Gago, JM Marchante-Gayón, M Ferrero, JIG Alonso
Analytical chemistry 82 (7), 2879-2887, 2010
182010
Comparison of GC–NCI MS, GC–ICP-MS, and GC–EI MS–MS for the determination of PBDEs in water samples according to the Water Framework Directive
A Gonzalez-Gago, D Pröfrock, A Prange
Analytical and bioanalytical chemistry 407, 8009-8018, 2015
142015
Evaluation of uncertainty sources in the determination of testosterone in urine by calibration-based and isotope dilution quantification using ultra high performance liquid …
J Pitarch-Motellón, AF Roig-Navarro, JV Sancho, M Ibáñez, ...
Journal of Chromatography A 1508, 73-80, 2017
132017
Determination of Priority Polybrominated Diphenyl Ethers by Isotope Dilution Gas Chromatography(Electron Ionization)MS Using 81Br-Labeled Standards
A González-Gago, JM Marchante-Gayón, JIG Alonso
Analytical chemistry 83 (8), 3024-3032, 2011
112011
Potential reference measurement procedures for PBDE in surface water at levels required by the EU Water Frame Directive
C Swart, F Gantois, P Petrov, J Entwisle, H Goenaga-Infante, ...
Talanta 152, 251-258, 2016
102016
An interlaboratory comparison on whole water samples
J Richter, S Elordui-Zapatarietxe, H Emteborg, I Fettig, J Cabillic, ...
Accreditation and Quality Assurance 21, 121-129, 2016
102016
Evaluation of different internal standardization approaches for the quantification of melatonin in cell culture samples by multiple heart-cutting two dimensional liquid …
AS Fernández, AG Gago, FA Naveda, JG Calleja, A Zawadzka, ...
Journal of Chromatography A 1663, 462752, 2022
42022
Isotope dilution LC-ESI-MS/MS and low resolution selected reaction monitoring as a tool for the accurate quantification of urinary testosterone
AE Artabe, A González-Gago, AS Fernández, JP Motellón, ...
Journal of Pharmaceutical and Biomedical Analysis 163, 113-121, 2019
42019
Evaluation of the spectral accuracy of mass spectrometers using compounds containing Cl or Br atoms
L Somoano‐Blanco, M Borda, A González Gago, P Rodríguez‐González, ...
Journal of Mass Spectrometry 51 (11), 1036-1042, 2016
42016
Development and evaluation of an electrochemical biosensor for creatinine quantification in a drop of whole human blood
GÁ Menéndez, O Amor-Gutiérrez, AC García, M Funes-Menéndez, ...
Clinica Chimica Acta 543, 117300, 2023
32023
Isotope dilution LC-ESI-MS/MS and low resolution selected reaction monitoring as a tool for the accurate quantification of urinary testosterone
A Ereno Artabe, A Gonzalez-Gago, A Suarez Fernandez, ...
Elsevier, 2018
32018
Comparison between one and two-dimensional liquid chromatographic approaches for the determination of plasmatic stroke biomarkers by isotope dilution and tandem mass spectrometry
AC Giménez-Coral, P Rodríguez-González, AG Gago, EC Morollón, ...
Analyst 148 (3), 583-593, 2023
12023
Evaluation of different isotope dilution mass spectrometry strategies for the characterization of naturally abundant and isotopically labelled peptide standards
J Nicolás Carcelén, H Potes Rodríguez, A González-Gago, ...
Analytical and Bioanalytical Chemistry, 1-15, 2024
2024
Correction of creatine-creatinine conversion during serum creatinine quantification by two-dimensional liquid chromatography and double-spike isotope dilution tandem mass …
D Pineda-Cevallos, MF Menéndez, A González-Gago, ...
Clinica Chimica Acta 554, 117778, 2024
2024
Quantification of modified nucleotides and nucleosides by isotope dilution mass spectrometry
JM Marchante‐Gayón, J Nicolás Carcelén, H Potes Rodríguez, ...
Mass Spectrometry Reviews, 2023
2023
Comparison between one and two-dimensional liquid chromatographic approaches for the determination of plasmatic stroke biomarkers by isotope dilution and tandem mass spectrometry
CA Cortés Giménez, P Rodríguez González, A González Gago, ...
Analyst, 2022
2022
The system can't perform the operation now. Try again later.
Articles 1–20