Optimizing GC-ICP-MS for ultra-trace quantification of PBDEs in natural water samples using species-specific isotope dilution A González-Gago, D Pröfrock, A Prange Journal of Analytical Atomic Spectrometry 30 (1), 180-190, 2015 | 27 | 2015 |
Determination of trihalomethanes in drinking water by GC-ICP-MS using compound independent calibration with internal standard A González-Gago, JM Marchante-Gayón, JIG Alonso Journal of Analytical Atomic Spectrometry 22 (9), 1138-1144, 2007 | 26 | 2007 |
Determination of the uncertainties in the theoretical mass isotopomer distribution of molecules JIG Alonso, P Rodríguez-González, A González-Gago, ... Analytica chimica acta 664 (1), 68-76, 2010 | 21 | 2010 |
Determination of ultra-trace levels of priority PBDEs in water samples by isotope dilution GC(ECNI)MS using 81Br-labelled standards A González-Gago, SH Brandsma, PEG Leonards, J de Boer, ... Analytical and Bioanalytical Chemistry 401, 2639-2649, 2011 | 18 | 2011 |
Synthesis of 81Br-Labeled Polybrominated Diphenyl Ethers and Their Characterization Using GC(EI)MS and GC(ICP)MS A Gonzalez-Gago, JM Marchante-Gayón, M Ferrero, JIG Alonso Analytical chemistry 82 (7), 2879-2887, 2010 | 18 | 2010 |
Comparison of GC–NCI MS, GC–ICP-MS, and GC–EI MS–MS for the determination of PBDEs in water samples according to the Water Framework Directive A Gonzalez-Gago, D Pröfrock, A Prange Analytical and bioanalytical chemistry 407, 8009-8018, 2015 | 14 | 2015 |
Evaluation of uncertainty sources in the determination of testosterone in urine by calibration-based and isotope dilution quantification using ultra high performance liquid … J Pitarch-Motellón, AF Roig-Navarro, JV Sancho, M Ibáñez, ... Journal of Chromatography A 1508, 73-80, 2017 | 13 | 2017 |
Determination of Priority Polybrominated Diphenyl Ethers by Isotope Dilution Gas Chromatography(Electron Ionization)MS Using 81Br-Labeled Standards A González-Gago, JM Marchante-Gayón, JIG Alonso Analytical chemistry 83 (8), 3024-3032, 2011 | 11 | 2011 |
Potential reference measurement procedures for PBDE in surface water at levels required by the EU Water Frame Directive C Swart, F Gantois, P Petrov, J Entwisle, H Goenaga-Infante, ... Talanta 152, 251-258, 2016 | 10 | 2016 |
An interlaboratory comparison on whole water samples J Richter, S Elordui-Zapatarietxe, H Emteborg, I Fettig, J Cabillic, ... Accreditation and Quality Assurance 21, 121-129, 2016 | 10 | 2016 |
Evaluation of different internal standardization approaches for the quantification of melatonin in cell culture samples by multiple heart-cutting two dimensional liquid … AS Fernández, AG Gago, FA Naveda, JG Calleja, A Zawadzka, ... Journal of Chromatography A 1663, 462752, 2022 | 4 | 2022 |
Isotope dilution LC-ESI-MS/MS and low resolution selected reaction monitoring as a tool for the accurate quantification of urinary testosterone AE Artabe, A González-Gago, AS Fernández, JP Motellón, ... Journal of Pharmaceutical and Biomedical Analysis 163, 113-121, 2019 | 4 | 2019 |
Evaluation of the spectral accuracy of mass spectrometers using compounds containing Cl or Br atoms L Somoano‐Blanco, M Borda, A González Gago, P Rodríguez‐González, ... Journal of Mass Spectrometry 51 (11), 1036-1042, 2016 | 4 | 2016 |
Development and evaluation of an electrochemical biosensor for creatinine quantification in a drop of whole human blood GÁ Menéndez, O Amor-Gutiérrez, AC García, M Funes-Menéndez, ... Clinica Chimica Acta 543, 117300, 2023 | 3 | 2023 |
Isotope dilution LC-ESI-MS/MS and low resolution selected reaction monitoring as a tool for the accurate quantification of urinary testosterone A Ereno Artabe, A Gonzalez-Gago, A Suarez Fernandez, ... Elsevier, 2018 | 3 | 2018 |
Comparison between one and two-dimensional liquid chromatographic approaches for the determination of plasmatic stroke biomarkers by isotope dilution and tandem mass spectrometry AC Giménez-Coral, P Rodríguez-González, AG Gago, EC Morollón, ... Analyst 148 (3), 583-593, 2023 | 1 | 2023 |
Evaluation of different isotope dilution mass spectrometry strategies for the characterization of naturally abundant and isotopically labelled peptide standards J Nicolás Carcelén, H Potes Rodríguez, A González-Gago, ... Analytical and Bioanalytical Chemistry, 1-15, 2024 | | 2024 |
Correction of creatine-creatinine conversion during serum creatinine quantification by two-dimensional liquid chromatography and double-spike isotope dilution tandem mass … D Pineda-Cevallos, MF Menéndez, A González-Gago, ... Clinica Chimica Acta 554, 117778, 2024 | | 2024 |
Quantification of modified nucleotides and nucleosides by isotope dilution mass spectrometry JM Marchante‐Gayón, J Nicolás Carcelén, H Potes Rodríguez, ... Mass Spectrometry Reviews, 2023 | | 2023 |
Comparison between one and two-dimensional liquid chromatographic approaches for the determination of plasmatic stroke biomarkers by isotope dilution and tandem mass spectrometry CA Cortés Giménez, P Rodríguez González, A González Gago, ... Analyst, 2022 | | 2022 |